1、Designation:E130012 Designation: E1300 12aStandard Practice forDetermining Load Resistance of Glass in Buildings1This standard is issued under the fixed designation E1300; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、 last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes procedures to determine the load resistance (LR) of specified glass types, including combinat
3、ionsof glass types used in a sealed insulating glass (IG) unit, exposed to a uniform lateral load of short or long duration, for a specifiedprobability of breakage.1.2This1.2 This practice applies to vertical and sloped glazing in buildings for which the specified design loads consist of windload, s
4、now load and self-weight with a total combined magnitude less than or equal to 15 kPa (315 psf). This practice shall notapply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members, andglass shelves.1.3 This practice applies only to
5、monolithic and laminated, glass constructions of rectangular shape with continuous lateralsupport along one, two, three, or four edges. This practice assumes that (1) the supported glass edges for two, three, and four-sidedsupport conditions are simply supported and free to slip in plane; (2) glass
6、supported on two sides acts as a simply supported beam;and (3) glass supported on one side acts as a cantilever. For insulating glass units, this practice only applies to insulating glass unitswith four-sided edge support.1.4 This practice does not apply to any form of wired, patterned, etched, sand
7、blasted, drilled, notched, or grooved glass withsurface and edge treatments that alter the glass strength.1.5 This practice addresses only the determination of the resistance of glass to uniform lateral loads. The final thickness and typeof glass selected also depends upon a variety of other factors
8、 (see 5.3).1.6 Charts in this practice provide a means to determine approximate maximum lateral glass deflection. Appendix X1 providesadditional procedures to determine maximum lateral deflection for glass simply supported on four sides. Appendix X2 presents aprocedure to compute approximate probabi
9、lity of breakage for annealed (AN) monolithic glass lites simply supported on four sides.provides additional procedures to determine maximum lateral deflection for glass simply supported on four sides.1.7 The values stated in SI units are to be regarded as the standard. The values given in parenthes
10、es are for mathematicalconversions to inch-pound units that are provided for information only and are not considered standard.1.8 Appendix X3 Appendix X2 lists the key variables used in calculating the mandatory type factors in Tables 1-3 andcomments on their conservative values.1.9 This standard do
11、es not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Stand
12、ards:2C1036 Specification for Flat GlassC1048 Specification for Heat-Strengthened and Fully Tempered Flat GlassC1172 Specification for Laminated Architectural Flat GlassD4065 Practice for Plastics: Dynamic Mechanical Properties: Determination and Report of ProceduresE631 Terminology of Building Cons
13、tructions3. Terminology3.1 Definitions:3.1.1 Refer to Terminology E631 for additional terms used in this practice.1This practice is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.51 on Performanceof Windows, Doors, Skylig
14、hts and Curtain Walls.Current edition approvedApril 15,May 1, 2012. Published June 2012. Originally approved in 1989. Last previous edition approved in 20092012 as E130009a.E1300 12.DOI: 10.1520/E1300-12A.2For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Ser
15、vice at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previ
16、ous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM Int
17、ernational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2 Definitions of Terms Specific to This Standard:3.2.1 aspect ratio (AR), nfor glass simply supported on four sides, the ratio of the long dimension of the glass to the shortdimension of the glass is al
18、ways equal to or greater than 1.0. For glass simply supported on three sides, the ratio of the length ofone of the supported edges perpendicular to the free edge, to the length of the free edge, is equal to or greater than 0.5.3.2.2 etched glass, nglass surface that has been attacked with hydrofluor
19、ic acid or other agent, generally for marking ordecoration.3.2.3 glass breakage, nthe fracture of any lite or ply in monolithic, laminated, or insulating glass.3.2.4 Glass Thickness:3.2.4.1 thickness designation for monolithic glass, na term that defines a designated thickness for monolithic glass a
20、sspecified in Table 4 and Specification C1036.3.2.4.2 thickness designation for laminated glass (LG), na term used to specify a LG construction based on the combinedthicknesses of component plies.(1) Add the minimum thicknesses of the individual glass plies and the nominal interlayer thickness. If t
21、he sum of all interlayerthicknesses is greater than 1.52 mm (0.060 in.) use 1.52 mm (0.060 in.) in the calculation.TABLE 1 Glass Type Factors (GTF) for a Single Lite ofMonolithic or Laminated Glass (LG)GTFGlass Type Short Duration Load (3 s) Long Duration Load (30 days)AN 1.0 0.43HS 2.0 1.3FT 4.0 3.
22、0TABLE 2 Glass Type Factors (GTF) for Double Glazed InsulatingGlass (IG), Short Duration LoadLite No. 1Monolithic Glass orLaminated Glass TypeLite No. 2Monolithic Glass or Laminated Glass TypeAN HS FTGTF1 GTF2 GTF1 GTF2 GTF1 GTF2AN 0.9 0.9 1.0 1.9 1.0 3.8HS 1.9 1.0 1.8 1.8 1.9 3.8FT 3.8 1.0 3.8 1.9
23、3.6 3.6TABLE 3 Glass Type Factors (GTF) for Double Glazed InsulatingGlass (IG), Long Duration Load (30 day)Lite No. 1Monolithic Glass orLaminated Glass TypeLite No. 2Monolithic Glass or Laminated Glass TypeAN HS FTGTF1 GTF2 GTF1 GTF2 GTF1 GTF2AN 0.39 0.39 0.43 1.25 0.43 2.85HS 1.25 0.43 1.25 1.25 1.
24、25 2.85FT 2.85 0.43 2.85 1.25 2.85 2.85TABLE 4 Nominal and Minimum Glass ThicknessesNominalThickness orDesignation,mm (in.)MinimumThickness,mm (in.)2.5 (332) 2.16 (0.085)2.7 (lami) 2.59 (0.102)3.0 (18) 2.92 ( 0.115)4.0 (532) 3.78 ( 0.149)5.0 (316) 4.57 (0.180)6.0 (14) 5.56 (0.219)8.0 (516) 7.42 (0.2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13002012ARED3750STANDARDPRACTICEFORDETERMININGLOADRESISTANCEOFGLASSINBUILDINGS 测定 建筑 玻璃 负载 电阻 标准

链接地址:http://www.mydoc123.com/p-528358.html