ASTM E1257-2016 Standard Guide for Evaluating Grinding Materials Used for Surface Preparation in Spectrochemical Analysis《在光谱化学分析中用于表面制备的研磨材料的评估标准指南》.pdf
《ASTM E1257-2016 Standard Guide for Evaluating Grinding Materials Used for Surface Preparation in Spectrochemical Analysis《在光谱化学分析中用于表面制备的研磨材料的评估标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1257-2016 Standard Guide for Evaluating Grinding Materials Used for Surface Preparation in Spectrochemical Analysis《在光谱化学分析中用于表面制备的研磨材料的评估标准指南》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1257 93 (Reapproved 2008)E1257 16Standard Guide forEvaluating Grinding Materials Used for Surface Preparationin Spectrochemical Analysis1This standard is issued under the fixed designation E1257; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers recommendations for the evaluation of various grinding materi
3、als used to prepare the surfaces ofspecimens to be analyzed by optical spark atomic emission or X-ray emission spectroscopy.fluorescence spectrometry.1.2 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibilityof the user of this
4、 standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E135 Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials3. Terminology3.1 For definitions o
5、f terms used in this guide, refer to Terminology E135.4. Significance and Use4.1 The grinding materials used for the preparation of the surfaces of specimens prior to analysis by optical spark atomicemission or X-ray emission spectroscopyfluorescence spectrometry can contaminate the surface and thus
6、 produce erroneousresults.This guide provides examples of the effects of these contaminations and recommendations for evaluating grinding materialsto eliminate or reduce these effects in spectrochemical analysis.4.2 The examples given in this guide are not the only contaminations whichthat can occur
7、. Especially in X-ray spectrometry,all phases of the surface preparation should be examined for potential contamination effects.4.3 Analytical significance of the contaminations observed depends on the needs of the analyst for the particular application ata given concentration position.5. Evaluation
8、 of Grinding Materials by Direct Analysis5.1 Table 1 shows an example of semiquantitative spectrographicspectrometric analysis of various grinding belts from differentproducers. An examination of these analyses identifies the elements most likely to contaminate the surface of the specimen. Themore c
9、ritical the element and the lower its concentration mass fraction in the specimen, the more important are low-levelconcentrationscontaminants in the belts.5.1.1 For example, using the 80-grit zircon belt in the determination of 0.5 % chromium, the trace level of chromium in the beltshould cause no p
10、roblem, but in the determination of 0.02 % aluminum, that belt probably will cause a problem. In thedetermination of calcium at ppmg/g levels in steel, even low levels of calcium in the belts cause problems.5.2 Figs. 1-6 show energy dispersive X-ray analyses of various belts and the same logic appli
11、ed in 5.1 can be used with theseanalyses. Major components in the belts will cause greater problems in the determination of these elements.1 This guide is under the jurisdiction of ASTM Committee E01 on Analytical Chemistry for Metals, Ores, and Related Materials and is the direct responsibility ofS
12、ubcommittee E01.20 on Fundamental Practices.Current edition approved May 1, 2008Feb. 1, 2016. Published June 2008March 2016. Originally approved in 1988. Last previous edition approved in 20032008 asE1257 93 (2003).(2008). DOI: 10.1520/E1257-93R08.10.1520/E1257-16.2 For referencedASTM standards, vis
13、it theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standa
14、rd an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM
15、is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2.1 Direct analysis of the grinding material is particularly useful in such analyses as the determination of calcium in steel,where the analyt
16、e is generally too inhomogeneous to use the methods described in Section 6. This analysis requires a virtuallycalcium-free belt as in Fig. 2.TABLE 1 Semiquantitative (Spectrographic) Analysis of Grinding Belt AbrasivesConcentration,% 80-Grit Silicon Carbide 80-Grit Alumina 80-Grit ZirconNo. 1 No. 2
17、No. 3 No. 1 No. 2 No. 310+ Si Si Si Al Al, Ca Al Al, Ca, Zr110 Ca Ca Ti Si, Na, Fe0.11 Ba, Mg Fe, Al, Na Mg, Si, Ca, Ti Fe, Si, Na Ca Ti, Zn0.050.5 B Fe, B Mg0.010.1 Mn, Na B, Mg Al Ba, B Zr Na Mg0.0050.05 V, Cu, Ti, Ni Mn, Ti V, Ca, Na, Ni Mn, Zr, Cu, Na B B, Fe, Si B, Mn, SrTrace0.01 Mo, Zr, Sr Ba
18、, V, Zr, Cu,Ni, SrBa, Mn, Mg, Pb, Cr,Zr, Cu, Ti, SrNi Ba, Mn, Cr, V,Cu, Ni, SrMn, Mo, Cu,Sr, MgBa, Pb, Cr, V,Mo, CuTABLE 1 Semiquantitative (Spectrographic) Analysis of Grinding Belt AbrasivesComposition, % 80-Grit Silicon Carbide 80-Grit Alumina 80-Grit ZirconNo. 1 No. 2 No. 3 No. 1 No. 2 No. 310+
19、Si Si Si Al Al, Ca Al Al, Ca, Zr110 Ca Ca Ti Si, Na, Fe0.11 Ba, Mg Fe, Al, Na Mg, Si, Ca, Ti Fe, Si, Na Ca Ti, Zn0.050.5 B Fe, B Mg0.010.1 Mn, Na B, Mg Al Ba, B Zr Na Mg0.0050.05 V, Cu, Ti, Ni Mn, Ti V, Ca, Na, Ni Mn, Zr, Cu, Na B B, Fe, Si B, Mn, SrTrace0.01 Mo, Zr, Sr Ba, V, Zr, Cu,Ni, SrBa, Mn, M
20、g, Pb, Cr,Zr, Cu, Ti, SrNi Ba, Mn, Cr, V,Cu, Ni, SrMn, Mo, Cu,Sr, MgBa, Pb, Cr, V,Mo, CuTABLE 2 X-Ray Fluorescence Analysis of a Steel Specimen Using Various Grinding MediaApparent Concentration, %, UsingElement Si C Belt Alumina Belt Zircon Belt Resin BondedDiamond Metal BondedDiamond Diamond Paste
21、 Surface GrinderMolybdenum 0.057 0.056 0.058 0.057 0.057 0.057 0.058Niobium 0.034 0.032 0.032 0.033 0.032 0.032 0.033Copper 0.315 0.310 0.320 0.316 0.317 0.316 0.317Nickel 0.297 0.296 0.292 0.295 0.322A 0.296 0.295Cobalt 0.014 0.011 0.010 0.011 0.010 0.011 0.012Manganese 1.39 1.40 1.39 1.40 1.39 1.4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME12572016STANDARDGUIDEFOREVALUATINGGRINDINGMATERIALSUSEDFORSURFACEPREPARATIONINSPECTROCHEMICALANALYSIS

链接地址:http://www.mydoc123.com/p-528281.html