ASTM E1232-2007(2013) Standard Test Method for Temperature Limit of Flammability of Chemicals《化学药剂可燃性温度极限的标准试验方法》.pdf
《ASTM E1232-2007(2013) Standard Test Method for Temperature Limit of Flammability of Chemicals《化学药剂可燃性温度极限的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1232-2007(2013) Standard Test Method for Temperature Limit of Flammability of Chemicals《化学药剂可燃性温度极限的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1232 07 (Reapproved 2013)Standard Test Method forTemperature Limit of Flammability of Chemicals1This standard is issued under the fixed designation E1232; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe temperature limit of flammability test measures the minimum temperature at which liquid (orsolid) chemicals evolve s
3、ufficient vapors to form a flammable mixture with air under equilibriumconditions. This temperature is applicable for assessing flammability in large process vessels andsimilar equipment (Appendix X1 and Appendix X2).1. Scope1.1 This test method covers the determination of the mini-mum temperature a
4、t which vapors in equilibrium with a liquid(or solid) chemical will be sufficiently concentrated to formflammable mixtures in air at atmospheric pressure. This testmethod is written specifically for determination of the tempera-ture limit of flammability of systems using air as the source ofoxidant
5、and diluent. It may also be used for other oxidant/diluent combinations, including air plus diluent mixtures;however, no oxidant/diluent combination stronger than airshould be used. Also, no unstable chemical capable of explo-sive decomposition reactions should be tested (see 8.3).1.2 This test meth
6、od is designed and written to be run atlocal ambient pressure and is limited to a maximum initialpressure of 1 atm abs. It may also be used for reduced pressureswith the practical lower pressure limit being approximately13.3 kPa (100 mm Hg). The maximum practical operatingtemperature of this equipme
7、nt is approximately 150C (302F)(Note A1.2).1.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units are provided for informationonly and are not considered standard.1.4 This standard should be used to measure and
8、 describethe properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions, andshould not be used to describe or appraise the fire hazard or firerisk of materials, products, or assemblies under actual fireconditions. However, results of this tes
9、t may be used aselements of a fire risk assessment which takes into account allof the factors which are pertinent to an assessment of the firehazard of a particular end use.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibili
10、ty of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific safetyprecautions are given in Section 8.2. Referenced Documents2.1 ASTM Standards:2D3278 Test Methods for Flash Point of Liquids by
11、 SmallScale Closed-Cup ApparatusD3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD3941 Test Method for Flash Point by the EquilibriumMethod With a Closed-Cup ApparatusE220 Test Method for Calibration of Thermocouples ByComparison TechniquesE230 Specification and Temperature-Electrom
12、otive Force(EMF) Tables for Standardized ThermocouplesE502 Test Method for Selection and Use of ASTM Stan-dards for the Determination of Flash Point of Chemicalsby Closed Cup MethodsE537 Test Method for The Thermal Stability of Chemicalsby Differential Scanning CalorimetryE681 Test Method for Concen
13、tration Limits of Flammabilityof Chemicals (Vapors and Gases)E698 Test Method for Arrhenius Kinetic Constants forThermally Unstable Materials Using Differential Scan-ning Calorimetry and the Flynn/Wall/Ozawa Method1This test method is under the jurisdiction of ASTM Committee E27 on HazardPotential o
14、f Chemicals and is the direct responsibility of Subcommittee E27.04 onFlammability and Ignitability of Chemicals.Current edition approved Oct. 1, 2013. Published November 2013. Originallyapproved in 1991. Last previous edition approved in 2007 as E1232 07. DOI:10.1520/E1232-07R13.2For referenced AST
15、M standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohoc
16、ken, PA 19428-2959. United States12.2 ANSI Standard:3ANSI-MC96.1 Temperature Measurement Thermocouples2.3 NFPA Standard:4NFPA 325 Fire Hazardous Properties Liquids3. Terminology3.1 Definitions:3.1.1 flash pointthe lowest temperature, corrected to apressure of 101.3 kPa (760 mm Hg, 1013 mbar), at whi
17、chapplication of an ignition source causes the vapors of thespecimen to ignite under specified conditions of test.3.1.2 lower limit of flammability or lower flammable limit,(LFL)the minimum concentration of a combustible sub-stance that is capable of propagating a flame through ahomogeneous mixture
18、of the combustible and a gaseousoxidizer under the specified conditions of test.3.1.3 lower temperature limit of flammability, (LTL)thelowest temperature, corrected to a pressure of 101.3 kPa (760mm Hg, 1013 mbar), at which application of an ignition sourcecauses a homogeneous mixture of a gaseous o
19、xidizer andvapors in equilibrium with a liquid (or solid) specimen to igniteand propagate a flame away from the ignition source under thespecified conditions of test.3.2 Definitions of Terms Specific to This Standard:3.2.1 propagation of flamethe upward and outward move-ment of the flame front from
20、the ignition source to the vesselwalls, that is determined by visual observation.4. Summary of Test Method4.1 A pool of liquid is stirred in a closed vessel in an airatmosphere. The vapor-air mixture above this liquid is exposedto an ignition source and the upward and outward propagationof flame awa
21、y from the ignition source is noted by visualobservation. Temperature in the test vessel is varied betweentrials until the minimum temperature at which flame willpropagate away from the ignition source is determined.5. Significance and Use5.1 The lower temperature limit of flammability is theminimum
22、 temperature at which a liquid (or solid) chemical willevolve sufficient vapors to form a flammable mixture with airunder equilibrium conditions. Knowledge of this temperatureis important in determining guidelines for the safe handling ofchemicals, particularly in closed process and storage vessels.
23、NOTE 1As a result of physical factors inherent in flash point apparatusand procedures, closed-cup flash point temperatures are not necessarilythe minimum temperature at which a chemical will evolve flammablevapors (see Appendix X2 and Appendix X3, taken in part from TestMethod E502). The temperature
24、 limit of flammability test is designed tosupplement limitations inherent in flash point tests (Appendix X2). Ityields a result closely approaching the minimum temperature of flam-mable vapor formation for equilibrium situations in the chemical process-ing industry such as in closed process and stor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME123220072013STANDARDTESTMETHODFORTEMPERATURELIMITOFFLAMMABILITYOFCHEMICALS 化学 药剂 可燃性 温度 极限 标准 试验

链接地址:http://www.mydoc123.com/p-528225.html