《ASTM E1048-1988(2010) 1250 Standard Specification for Color-Coding Pipets or Containers Coated With Anticoagulants《抗凝剂涂覆的彩色编码吸管或容器的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1048-1988(2010) 1250 Standard Specification for Color-Coding Pipets or Containers Coated With Anticoagulants《抗凝剂涂覆的彩色编码吸管或容器的标准规范》.pdf(1页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1048 88 (Reapproved 2010)Standard Specification forColor-Coding Pipets or Containers Coated WithAnticoagulants1This standard is issued under the fixed designation E1048; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers a system to identify the anti-coagulants used in coating pipets or containers n
3、ot exceeding 1mL in volume.1.2 The purpose of this specification is to ensure that if acolor code is used with an anticoagulant, all manufacturers willbe encouraged to use the same code; it is not intended torequire color coding.1.3 The values stated in SI units are to be regarded asstandard. No oth
4、er units of measurement are included in thisstandard.2. Color Code2.1 The color coding used to identify the anticoagulant usedin coating the pipets shall be in accordance with Table 1.2.2 Variations in the enamels used and in the methods ofapplication appropriate for pipets made from different types
5、 ofglass inevitably result in minor variations of color, and it istherefore not appropriate to specify more closely the colorsmentioned in the table.3. Dimensions and Permissible Variations3.1 The color code shall consist of a color band 1-3 mmwide which shall completely encircle the pipet in a plan
6、eperpendicular to its longitudinal axis.3.2 The location of the color code shall not be more than 20mm from the top of the pipet.3.3 If other color code bands are used to indicate capacity,they shall be 2-6 mm wide. The anticoagulant color code bandshould be separated with a space of at least 5 mm.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1048198820101250STANDARDSPECIFICATIONFORCOLORCODINGPIPETSORCONTAINERSCOATEDWITHANTICOAGULANTS 抗凝剂

链接地址:http://www.mydoc123.com/p-527815.html