ASTM E1036-2015 7557 Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells 《使用参比电池的非聚能地面光电模组和陈列电性能的标.pdf
《ASTM E1036-2015 7557 Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells 《使用参比电池的非聚能地面光电模组和陈列电性能的标.pdf》由会员分享,可在线阅读,更多相关《ASTM E1036-2015 7557 Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells 《使用参比电池的非聚能地面光电模组和陈列电性能的标.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1036 15Standard Test Methods forElectrical Performance of Nonconcentrator TerrestrialPhotovoltaic Modules and Arrays Using Reference Cells1This standard is issued under the fixed designation E1036; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the electrical performance ofphotovoltaic modules an
3、d arrays under natural or simulatedsunlight using a calibrated reference cell.1.1.1 These test methods allow a reference module to beused instead of a reference cell provided the reference modulehas been calibrated using these test methods against a cali-brated reference cell.1.2 Measurements under
4、a variety of conditions are al-lowed; results are reported under a select set of reportingconditions (RC) to facilitate comparison of results.1.3 These test methods apply only to nonconcentrator ter-restrial modules and arrays.1.4 The performance parameters determined by these testmethods apply only
5、 at the time of the test, and imply no past orfuture performance level.1.5 These test methods apply to photovoltaic modules andarrays that do not contain series-connected photovoltaic mul-tijunction devices; such module and arrays should be testedaccording to Test Methods E2236.1.6 The values stated
6、 in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and h
7、ealth practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE772 Terminology of Solar Energy ConversionE927 Specification for Solar S
8、imulation for PhotovoltaicTestingE941 Test Method for Calibration of Reference Pyranom-eters WithAxis Tilted by the Shading Method (Withdrawn2005)3E948 Test Method for Electrical Performance of Photovol-taic Cells Using Reference Cells Under Simulated Sun-lightE973 Test Method for Determination of t
9、he Spectral Mis-match Parameter Between a Photovoltaic Device and aPhotovoltaic Reference CellE1021 Test Method for Spectral Responsivity Measurementsof Photovoltaic DevicesE1040 Specification for Physical Characteristics of Noncon-centrator Terrestrial Photovoltaic Reference CellsE1125 Test Method
10、for Calibration of Primary Non-Concentrator Terrestrial Photovoltaic Reference Cells Us-ing a Tabular SpectrumE1362 Test Method for Calibration of Non-ConcentratorPhotovoltaic Secondary Reference CellsE2236 Test Methods for Measurement of Electrical Perfor-mance and Spectral Response of Nonconcentra
11、tor Multi-junction Photovoltaic Cells and ModulesG173 Tables for Reference Solar Spectral Irradiances: DirectNormal and Hemispherical on 37 Tilted Surface3. Terminology3.1 DefinitionsDefinitions of terms used in these testmethods may be found in Terminology E772.3.2 Definitions of Terms Specific to
12、This Standard:3.2.1 nominal operating cell temperature, NOCT, nthetemperature of a solar cell inside a module operating at anambient temperature of 20C, an irradiance of 800 Wm2, andan average wind speed of 1 ms1.3.2.2 reporting conditions, RC, nthe device temperature,total irradiance, and reference
13、 spectral irradiance conditionsthat module or array performance data are corrected to.1These test methods are under the jurisdiction of ASTM Committee E44 onSolar, Geothermal and Other Alternative Energy Sources and are the directresponsibility of Subcommittee E44.09 on Photovoltaic Electric Power C
14、onversion.Current edition approved Feb. 1, 2015. Published March 2015. Originallyapproved in 1985. Last previous edition approved in 2012 as E1036 12. DOI:10.1520/E1036-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
15、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unite
16、d States13.3 Symbols:3.3.1 The following symbols and units are used in these testmethods:rtemperature coefficient of reference cell ISC,C1,current temperature coefficient of device under test,C1,(E)voltage temperature function of device under test,C1,Ccalibration constant of reference cell, Am2W1,Ca
17、djusted calibration constant of reference cell,Am2W1,CfNOCT Correction factor,C,(T)voltage irradiance correction function of device undertest, dimensionless,TNOCT cell-ambient temperature difference, C,Eirradiance, Wm2,Eoirradiance at RC, Wm2,FFfill factor, dimensionless,Icurrent, A,Impcurrent at ma
18、ximum power, A,Iocurrent at RC, A,Irshort-circuit current of reference cell (or module, see1.1.1 and 4.3.4), A,Iscshort-circuit current, A,Mspectral mismatch parameter, dimensionless,Pelectrical power, W,Pmmaximum power, W,Ttemperature, C,Taambient temperature, C,Tctemperature of cell in module, C,T
19、otemperature at RC, C,Trtemperature of reference cell, C,wind speed, ms1,Vvoltage, V,Vmpvoltage at maximum power, V,Vovoltage at RC, V, andVocopen-circuit voltage, V.4. Summary of Test Methods4.1 Measurement of the performance of a photovoltaicmodule or array illuminated by a light source consists o
20、fdetermining at least the following electrical characteristics:short-circuit current, open-circuit voltage, maximum power,and voltage at maximum power.4.2 These parameters are derived by applying the procedurein Section 8 to a set of current-voltage data pairs (I-V data)recorded with the test module
21、 or array operating in thepower-producing quadrant.4.3 Testing the performance of a photovoltaic device in-volves the use of a calibrated photovoltaic reference cell todetermine the total irradiance.4.3.1 The reference cell is chosen according to the spectraldistribution of the irradiance under whic
22、h it was calibrated, forexample, the direct normal or global spectrum. These spectraare defined by Tables G173. The reference cell thereforedetermines to which spectrum the test module or array perfor-mance is referred.4.3.2 The reference cell must match the device under testsuch that the spectral m
23、ismatch parameter is 1.00 6 0.05, asdetermined in accordance with Test Method E973.4.3.3 Recommended physical characteristics of referencecells are described in Specification E1040.4.3.4 Areference module may be used instead of a referencecell throughout these test methods provided 4.3.2 is satisfie
24、dand the short-circuit current of the reference module has beendetermined according to the procedures in these test methodsusing a reference cell.The reference module must also meet themodule package design requirements in Specification E1040,with the exception of the electrical connector requiremen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME103620157557STANDARDTESTMETHODSFORELECTRICALPERFORMANCEOFNONCONCENTRATORTERRESTRIALPHOTOVOLTAICMODULESANDARRAYSUSINGREFERENCECELLS

链接地址:http://www.mydoc123.com/p-527785.html