ASTM E372-2013 0178 Standard Test Method for Determination of Calcium and Magnesium in Magnesium Ferrosilicon by EDTA Titration《用乙二胺四乙酸滴定法测定镁硅铁合金中钙和镁的标准试验方法》.pdf
《ASTM E372-2013 0178 Standard Test Method for Determination of Calcium and Magnesium in Magnesium Ferrosilicon by EDTA Titration《用乙二胺四乙酸滴定法测定镁硅铁合金中钙和镁的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E372-2013 0178 Standard Test Method for Determination of Calcium and Magnesium in Magnesium Ferrosilicon by EDTA Titration《用乙二胺四乙酸滴定法测定镁硅铁合金中钙和镁的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E372 13Standard Test Method forDetermination of Calcium and Magnesium in MagnesiumFerrosilicon by EDTA Titration1This standard is issued under the fixed designation E372; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the chemical analysis of mag-nesium ferrosilicon having chemical compositions wit
3、hin thefollowing limits:Element Composition Range, %Aluminum 2.0 maxCalcium 0.25 to 3.00Carbon 0.50 maxCerium 1.0 maxChromium 0.50 maxMagnesium 2.00 to 12.00Manganese 1.0 maxSilicon 40.00 to 55.00Sulfur 0.025 maxTitanium 0.2 max1.2 This standard does not purport to address all of thesafety concerns,
4、 if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For generalprecautions to be observed in this test method, refer toPractices E50.2. Re
5、ferenced Documents2.1 ASTM Standards:2E29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE32 Practices for Sampling Ferroalloys and Steel Additivesfor Determination of Chemical CompositionE50 Practices for Apparatus, Reagents, and Safety Consid-erations
6、 for Chemical Analysis of Metals, Ores, andRelated MaterialsE135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE173 Practice for Conducting Interlaboratory Studies ofMethods for Chemical Analysis of Metals (Withdrawn1998)33. Terminology3.1 For definitions of term
7、s used in this test method refer toTerminology E135.4. Significance and Use4.1 This test method for the chemical analysis of metals andalloys is primarily intended to test such materials for compli-ance with compositional specifications. It is assumed that allwho use this test method will be trained
8、 analysts capable ofperforming common laboratory procedures skillfully andsafely. It is expected that work will be performed in a properlyequipped laboratory.5. Hazards5.1 For precautions to be observed in the use of certainreagents and equipment in this test method, refer to PracticesE50.5.2 Specif
9、ic hazard statements are given in 13.7.1 and 14.1.6. Sampling6.1 For procedures for sampling the material, refer toPractices E32.7. Rounding Calculated Values7.1 Calculated values shall be rounded to the desired num-ber of places as directed in Practice E29.8. Interlaboratory Studies8.1 This test me
10、thod has been evaluated in accordance withPractice E173, unless otherwise noted in the precision and biassection.1This test method is under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and are the directresponsibility of Subcommittee E01.01 on
11、 Iron, Steel, and Ferroalloys.Current edition approved Nov. 15, 2013. Published January 2014. Originallyapproved in 1976. Redesignated E372 in 1980. Last previous edition approved in2006 as E372 01 (2006). DOI: 10.1520/E0372-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or
12、contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Dri
13、ve, PO Box C700, West Conshohocken, PA 19428-2959. United States1CALCIUM AND MAGNESIUM BY THE(ETHYLENEDINITRILO)TETRAACETIC ACID(EDTA) TITRIMETRIC METHOD9. Scope9.1 This test method covers the determination of magne-sium in compositions from2%to12%andcalcium incompositions from 0.25 % to 3.0 %.10. S
14、ummary of Test Method10.1 After dissolution of the sample in nitric and hydroflu-oric acids, an ammonium hydroxide precipitation is made toseparate other elements from calcium and magnesium.Calcium, and magnesium plus calcium are titrated in separatealiquot portions after adding triethanolamine and
15、potassiumcyanide to mask residual traces of iron, copper, nickel,manganese, and aluminum that may be present. Calcium istitrated with disodium (ethylenedinitrilo)tetraacetate (EDTA)at pH 12. Magnesium plus calcium is titrated with EDTA at pH10.0 and the magnesium content is calculated by correcting
16、forthe volume of EDTA required to titrate the calcium.11. Interferences11.1 Provision is made for the removal or masking ofinterfering elements ordinarily present in magnesium ferrosili-con.12. Apparatus12.1 Beakers, TFE-fluorocarbon 500-mL.12.2 pH Meter.13. Reagents13.1 Ammonium Chloride Buffer Sol
17、ution (pH 10.0)Dissolve 60 g of ammonium chloride (NH4Cl) in 200 mL ofwater, add 570 mL of NH4OH, and dilute to 1 L.13.2 Calcium, Standard Solution (1 mL = 0.2002 mg Ca)Dissolve 0.5000 g of calcium carbonate (CaCO3) (purity:99.9 % min) in 100 mL of HCl (5 + 95). Boil 1 min, cool,transfer to a 1-L vo
18、lumetric flask, dilute to volume, and mix.13.3 Disodium Ethylenedinitrilo-Tetraacetate Dihydrate(EDTA), Standard Solution: (0.005 M)13.3.1 Dissolve 1.8613 g of EDTA in water; transfer to a1-L volumetric flask; dilute to volume; and mix. The solutionwill remain stable for several months when stored i
19、n plastic orborosilicate glass bottles.13.3.2 Standardize the solution as follows: Using a pipet,tranfer 25 mL of the calcium solution (1 mL = 0.2002 mg Ca)to a 250-mL beaker, add 1 mL of MgCl2(13.6) solution and100 mL of water, and proceed as directed in 14.4.NOTE 1Containers used for the storage o
20、f dilute solutions of EDTAshould be pretreated with a hot alkaline EDTA solution (10 g/L), andrinsed with water.13.3.3 Calculate the calcium equivalent of the EDTA solu-tion as follows:Calcium equivalent, mg/mL 5 A/B (1)where:A = calcium, mg, andB = EDTA solution required to titrate the calcium solu
21、tion,mL.13.3.4 Calculate the magnesium equivalent of the solutionas follows:Magnesium equivalent, mg/mL 5 C 30.6068 (2)where C = calcium equivalent (13.3.3).13.4 Eriochrome Black-T Indicator Solution (6 g/L ofmethanol)Dissolve 0.3 g of Eriochrome Black-T and1gofsodium borate decahydrate (Na2B4O710H2
22、O) in 50 mL ofmethanol. Do not use a solution that has stood for more than 8h.13.5 Hydroxy Naphthol Blue MixtureAdd 1.0 g of hy-droxy napthol blue indicator to 100 g NaCl and mix thor-oughly.13.6 Magnesium Chloride (2.5 g/L) Dissolve 0.25 g ofmagnesium chloride hexahydrate (MgCl26H2O) in 50 mL ofwat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便