ASTM D8018-2015 1489 Standard Test Method for Determination of (Tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC) in Soil by Multiple Reaction Monitoring Liquid Chromatography M.pdf
《ASTM D8018-2015 1489 Standard Test Method for Determination of (Tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC) in Soil by Multiple Reaction Monitoring Liquid Chromatography M.pdf》由会员分享,可在线阅读,更多相关《ASTM D8018-2015 1489 Standard Test Method for Determination of (Tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC) in Soil by Multiple Reaction Monitoring Liquid Chromatography M.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D8018 15Standard Test Method forDetermination of (Tri-n-butyl)-n-tetradecylphosphoniumchloride (TTPC) in Soil by Multiple Reaction MonitoringLiquid Chromatography/Mass Spectrometry (LC/MS/MS)1This standard is issued under the fixed designation D8018; the number immediately following the
2、 designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This procedure covers the
3、 determination of (Tri-n-butyl)-n-tetradecylphosphonium chloride (TTPC) in a soilmatrix by extraction with acetone, filtration, dilution withwater, and analysis by liquid chromatography/tandem massspectrometry. TTPC is a biocide that strongly adsorbs to soils.2The sample extracts are prepared in a s
4、olution of 75 % acetoneand 25 % water because TTPC has an affinity for surfaces andparticles. The reporting range for this method is from 250 to10 000 ng/kg. This analyte is qualitatively and quantitativelydetermine by this method. This method adheres to multiplereaction monitoring (MRM) mass spectr
5、ometry.1.2 The Method Detection Limit (Note 1) (MDL) andReporting Range (Note 2) for the target analyte are listed inTable 1.NOTE 1The MDL is determined following the Code of FederalRegulations, 40 CFR Part 136, Appendix B, as a guide utilizing solventextraction of soil. Two-gram sample of Ottawa Sa
6、nd was utilized. Adetailed process determining the MDL is explained in the reference and isbeyond the scope of this standard to be explained here.NOTE 2Reporting range concentration is calculated from Table 2concentrations assuming a 50 L injection of the Level 1 calibrationstandard forTTPC, and the
7、 highest level calibration standard with a 20 mLfinal extract volume ofa2gsoil sample. Volume variations will changethe reporting limit and ranges.1.2.1 The reporting limit in this test method is the minimumvalue below which data are documented as non-detects. Ana-lyte detections between the method
8、detection limit and thereporting limit are estimated concentrations and are not re-ported following this test method. The reporting limit iscalculated from the concentration of the Level 1 calibrationstandard as shown in Table 2 for TTPC after taking intoaccounta2gsample weight and a final extract v
9、olume of 20mLin 75 % acetone/25 % water. The final extract volume is 20mL because a 15 mL volume of acetone is added to each soilsample and only the liquid layer after extraction is filteredleaving the solid behind followed by the addition of 5 mL ofwater to the acetone extract.1.3 UnitsThe values s
10、tated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
11、and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD5681 Terminology for
12、 Waste and Waste ManagementD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE2554 Practice for Estimating and Monitoring the Uncer-tainty of Test Results of a Test Method Using ControlChart Techniques2.2 Other Documents:4EPA Publication SW-846 Test
13、 Methods for Evaluating SolidWaste, Physical/Chemical Methods40 CFR Part 136, Appendix B Definition and Procedure forthe Determination of the Method Detection Limit3. Terminology3.1 For determinations of terms used in this standard, referto Terminology D5681.1This test method is under the jurisdicti
14、on of ASTM Committee D34 on WasteManagement and is the direct responsibility of Subcommittee D34.01.06 onAnalytical Methods.Current edition approved Nov. 1, 2015. Published November 2015. DOI:10.1520/D8018-15.2More information on TTPC can be found at http:/ Biocide-BE-91.pdf(2014) and http:/iaspub.e
15、pa.gov/sor_internet/registry/substreg/searchandretrieve/advancedsearch/externalSearch.do?p_type=CASNO however, this test method is intended to be performancebased and alternative operating conditions can be used toperform this method provided data quality objectives areattained. Mention of trade nam
16、es or suppliers is not anendorsement of use, it is provided for informational purposesonly. Any apparatus, supply, standard, or reagent may be usedprovided that it is shown to be acceptable to meet theperformance criteria of the method.4.2 ForTTPC analysis, samples are shipped to the lab on iceand a
17、nalyzed within 14 days of collection. A sample (2 g) istransferred to a VOA vial, a TTPC spike solution is added toLaboratory Control and Matrix Spike samples before theaddition of acetone. An isotopically labeled TTPC surrogatecould be added at this point, presently requires a customsynthesis and s
18、hould be incorporated into this method by theuser if requested by the customer.5Then add 15 mL of acetoneand hand shake or vortex for one minute. The samples areallowed to settle, and are then filtered through a Nylonmembrane syringe driven filter unit6leaving the solids behind,5 mLofASTM Type 1 wat
19、er is added to the filtered extract andthen analyzed by LC/MS/MS.All concentrations reported, onlyto the reporting limit, using this method are based upon a dryweight basis.4.3 TTPC is identified by comparing the single reactionmonitoring (SRM) transition and its confirmatory SRM tran-sitions if cor
20、related to the known standard SRM transition(Table 3) and quantitated utilizing an external calibration. Thefinal report issued for each sample lists the concentration ofTTPC, if detected, or RL, if not detected, in ng/kg (Dry WeightBasis) and surrogate recovery, if available.5. Significance and Use
21、5.1 This test method has been developed by the US EPARegion 5 Chicago Regional Laboratory (CRL).5.2 TTPC may be used in various industrial and commercialproducts for use as a biocide. Products containing TTPC havebeen approved for controlling algal, bacterial, and fungalslimes in industrial water sy
22、stems.2TTPC should not bepersistent in water but may be deposited in sediments atconcentrations of concern. Hence, there is a need for quick,easy, and robust method to determine TTPC concentration attrace levels in various soil matrices for understanding thesources and concentration levels in affect
23、ed soils and sedi-ments.5.3 This method has been used to determine TTPC in sand,a commercial top soil and fourASTM reference soils (Table 4).6. Interferences6.1 All glassware is washed in hot water with detergent andrinsed in hot water followed by distilled water. The glasswareis then dried and heat
24、ed in an oven at 250C for 15 to 30minutes. All glassware is subsequently rinsed or sonicated, orboth, with acetone, n-propanol, or acetonitrile, or combinationsthereof.6.2 TTPC should not be a common contaminant found in alaboratory, unless involved in the analysis or matrices that5A custom synthesi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD801820151489STANDARDTESTMETHODFORDETERMINATIONOFTRINBUTYLNTETRADECYLPHOSPHONIUMCHLORIDETTPCINSOILBYMULTIPLEREACTIONMONITORINGLIQUIDCHROMATOGRAPHYMPDF

链接地址:http://www.mydoc123.com/p-526641.html