ASTM D7597-2016 9557 Standard Test Method for Determination of Diisopropyl Methylphosphonate Ethyl Hydrogen Dimethylamidophosphate Ethyl Methylphosphonic Acid Isopropyl Methylphosp.pdf
《ASTM D7597-2016 9557 Standard Test Method for Determination of Diisopropyl Methylphosphonate Ethyl Hydrogen Dimethylamidophosphate Ethyl Methylphosphonic Acid Isopropyl Methylphosp.pdf》由会员分享,可在线阅读,更多相关《ASTM D7597-2016 9557 Standard Test Method for Determination of Diisopropyl Methylphosphonate Ethyl Hydrogen Dimethylamidophosphate Ethyl Methylphosphonic Acid Isopropyl Methylphosp.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7597 16Standard Test Method forDetermination of Diisopropyl Methylphosphonate, EthylHydrogen Dimethylamidophosphate, EthylMethylphosphonic Acid, Isopropyl Methylphosphonic Acid,Methylphosphonic Acid and Pinacolyl MethylphosphonicAcid in Water by Liquid Chromatography/Tandem MassSpectro
2、metry1This standard is issued under the fixed designation D7597; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indi
3、cates an editorial change since the last revision or reapproval.1. Scope1.1 This procedure covers the determination of diisopropylmethylphosphonate (DIMP), ethyl hydrogen dimethylami-dophosphate (EHDMAP), ethyl methylphosphonic acid(EMPA), isopropyl methylphosphonic acid (IMPA), methyl-phosphonic ac
4、id (MPA) and pinacolyl methylphosphonic acid(PMPA) (referred to collectively as organophosphonates in thistest method) in surface water by direct injection using liquidchromatography (LC) and detected with tandem mass spec-trometry (MS/MS) using electrospray ionization (ESI). Theseanalytes are quali
5、tatively and quantitatively determined by thismethod. This method adheres to single reaction monitoring(SRM) mass spectrometry.1.2 This test method has been developed by US EPARegion5 Chicago Regional Laboratory (CRL).1.3 The values stated in SI units are to be regarded asstandard. No other units of
6、 measurement are included in thisstandard.1.4 The detection verification level (DVL) and reportingrange for the organophosphonates are listed in Table 1.1.4.1 The DVL is required to be at a concentration at leastthree times below the reporting limit (RL) and have a signal/noise ratio greater than 3:
7、1. Fig. 1 displays the signal/noiseratios at the DVLs for the organophosphonates in the ESIpositive mode and Fig. 2 in the ESI negative mode.1.4.2 The reporting limit is the concentration of the Level 1calibration standard as shown in Table 2 for the organophos-phonates except for MPAin the ESI nega
8、tive mode which is atLevel 2 due to not meeting the DVL criteria at the lowerconcentration level. The DVL for MPA in the ESI negativemode is at 20 g/L, which forces a raised reporting limit.However, the multi-laboratory validation required a spike of alltarget analytes at Level 1 concentrations. The
9、 mean recoveryfor MPA in the ESI negative mode at this level was 98.7 % asshown in Table 3. If your instruments sensitivity can meet therequirements in this test method, MPA may have a 50 g/Lreporting limit.1.5 This standard does not purport to address all of thesafety concerns, if any, associated w
10、ith its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagen
11、t WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3856 Guide for Management Systems in LaboratoriesEngaged in Analysis of WaterD3694 Practices for Preparation of Sample Containers andfor Preservation of Organic ConstituentsD5847 Practic
12、e for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE2554 Practice for Estimating and Monitoring the Uncer-tainty of Test Results of a Test Method Using ControlChart Techniques1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the dir
13、ect responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved Feb. 1, 2016. Published May 2016. Originallyapproved in 2009. Last previous edition approved in 2009 as D7597 091. DOI:10.1520/D7597-16.2For referenced ASTM standards, visit the A
14、STM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unit
15、ed States12.2 Other Documents:3EPA Publication SW-846 Test Methods for Evaluating SolidWaste, Physical/Chemical Methods3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this standard, refer toTerminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 detection veri
16、fication level, DVL, na concentrationthat has a signal/noise ratio greater than 3:1 and is at least 3times below the reporting limit (RL).3.2.2 independent reference material, IRM, na material ofknown purity and concentration obtained either from theNational Institute of Standards andTechnology (NIS
17、T) or otherreputable supplier. The IRM shall be obtained from a differentlot of material than is used for calibration.3.2.3 organophosphonates, nin this test method, diisopro-pyl methylphosphonate (DIMP), ethyl hydrogen dimethylami-dophosphate (EHDMAP), ethyl methylphosphonic acid(EMPA), isopropyl m
18、ethylphosphonic acid (IMPA), methyl-phosphonic acid (MPA) and pinacolyl methylphosphonic acid(PMPA).3.3 Acronyms:3.3.1 CCC, nContinuing Calibration Check3.3.2 IC, nInitial Calibration3.3.3 LC, nLiquid Chromatography3Available from United States Environmental Protection Agency (EPA), ArielRios Bldg.,
19、 1200 Pennsylvania Ave., NW, Washington, DC 20460, http:/www.epa.gov.TABLE 1 Detection Verification Level and Reporting RangeAnalyte ESI Mode DVL (g/L) Reporting Range (g/L)Diisopropyl methylphosphonate Positive 1 5150Ethyl hydrogen dimethylamidophosphate Negative 0.25 5150Ethyl hydrogen dimethylami
20、dophosphate Positive 0.25 5150Ethyl methylphosphonic acid Negative 5 501500Ethyl methylphosphonic acid Positive 5 501500Isopropyl methylphosphonic acid Negative 10 501500Isopropyl Methylphosphonic acid Positive 5 501500Methylphosphonic acid Negative 20 1001500Methylphosphonic acid Positive 10 501500
21、Pinacolyl methylphosphonic acid Negative 5 501500Pinacolyl methylphosphonic acid Positive 5 501500FIG. 1 Example ESI Positive Mode SRM Chromatograms Signal/Noise RatiosD7597 1623.3.4 LCS/LCSD, nLaboratory Control Sample/Laboratory Control Sample Duplicate3.3.5 MDL, nMethod Detection Limit3.3.6 MeOH,
22、 nMethanol3.3.7 mM, nmillimolar,110-3moles/L3.3.8 MRM, nMultiple Reaction Monitoring3.3.9 MS/MSD, nMatrix Spike/Matrix Spike Duplicate3.3.10 NA, adjNot Available3.3.11 ND, nnon-detect3.3.12 P diisopropylmethylphosphonate-D14, pinacolyl methylphosphonic acid-13C6and methylphosphonic acid-D3are identi
23、fied by retentionFIG. 2 Example ESI Negative Mode SRM Chromatograms Signal/Noise RatiosTABLE 2 Concentrations of Calibration Standards (PPB)Analyte/Surrogate LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 7Diisopropyl methylphosphonate 5 10 20 35 50 100 150Ethyl hydrogen dimethylamidophosphate 5 10 20 35 50 100 1
24、50Ethyl methylphosphonic acid 50 100 200 350 500 1000 1500Isopropyl methylphosphonic acid 50 100 200 350 500 1000 1500Methylphosphonic acid 50 100 200 350 500 1000 1500Pinacolyl methylphosphonic acid 50 100 200 350 500 1000 1500DIMP-D14 (Surrogate) 5 10 20 35 50 100 150PMPA-13C4 (Surrogate) 25 50 10
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD759720169557STANDARDTESTMETHODFORDETERMINATIONOFDIISOPROPYLMETHYLPHOSPHONATEETHYLHYDROGENDIMETHYLAMIDOPHOSPHATEETHYLMETHYLPHOSPHONICACIDISOPROPYLMETHYLPHOSPPDF

链接地址:http://www.mydoc123.com/p-525915.html