ASTM D7487-2013e1 9579 Standard Practice for Polyurethane Raw Materials Polyurethane Foam Cup Test《聚氨酯原材料的标准实施规程 聚氨酯泡沫杯试验》.pdf
《ASTM D7487-2013e1 9579 Standard Practice for Polyurethane Raw Materials Polyurethane Foam Cup Test《聚氨酯原材料的标准实施规程 聚氨酯泡沫杯试验》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7487-2013e1 9579 Standard Practice for Polyurethane Raw Materials Polyurethane Foam Cup Test《聚氨酯原材料的标准实施规程 聚氨酯泡沫杯试验》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7487 131Standard Practice forPolyurethane Raw Materials: Polyurethane Foam Cup Test1This standard is issued under the fixed designation D7487; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorially corrected Table X1.5 and Table X1.6 in March 2016.1. Scope1.1 This practice covers the determination of cream time(initiation t
3、ime), top of cup time, free rise time, free rise height,string gel time (pull time), tack free time, settle back, and freerise density of polyurethane foam formulations using a cupfoam test.1.2 Typical definitions, terms, and techniques are described;including procedures for mixing and transferring
4、samples tothe foaming container; and data gathering and evaluation.However, agreement between the customer and the testinglaboratory for all these items must be obtained prior to use.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisst
5、andard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1Th
6、ere is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 DefinitionsTerminology used in this practice followsthat d
7、efined in Terminology D883.3.2 Definitions of Terms Specific to This Standard:3.2.1 cream time (initiation time)the time between thestart of mixing and the point at which fine bubbles begin toappear.3.2.2 top of cup timethe time at which the crown of therising foam reaches the plane of the top of th
8、e cup.3.2.3 free rise time (end of rise time)the time at which thefoam stops expanding as observed visually.3.2.4 string gel time (pull time)time at which long“strings” of tacky material can be pulled away from the surfaceof the foam when the surface is touched by the edge of a tonguedepressor or si
9、milar implement.3.2.5 tack free timethe time at which the surface of thefoam can be touched with a gloved finger or tongue depressorwithout sticking.3.2.6 free rise densitythe density in kg/m3of a polyure-thane foam prepared in an open cup.3.2.7 free rise heightheight of the foam at free rise time3.
10、2.8 final heightheight of foam after specified time3.2.9 % settle back (% recession, % sigh back, or % sinkback)percentage decrease from free rise height to final height3.2.10 resin blend (formulated polyol)complete ingredientformulation without the isocyanate4. Summary of Practice4.1 Specific event
11、s (cream time, initiation time, top of cuptime, free rise time, free rise height, string gel time, and tackfree time) from a polyurethane foamed in a cup are measuredto verify the resin blend composition or levels of ingredients informulations used to make polyurethane foams.4.2 An estimation of the
12、 method precision is given. Anestimation of bias is not given because there is no suitablereference method.5. Significance and Use5.1 General Utility:5.1.1 It is useful to verify catalyst levels in a resin blend ora polyurethane system.5.1.2 This practice is suitable for research, quality control,sp
13、ecification testing, and process control.1This practice is under the jurisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.22 on Cellular Materials - Plasticsand Elastomers.Current edition approved Nov. 1, 2013. Published November 2013. Originallyapproved
14、in 2008. Last previous edition approved in 2008 as D7487 - 08.DOI:10.1520/D7487-13E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary
15、 page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 Limitations:5.2.1 Several of the measured parameters are subjective.Therefore, operator-to-operator variability and lab-to-lab vari-ability can be much highe
16、r than that of a single operator.5.2.2 The variability of this practice is dependent on theconsistency of mixing of the reactants.5.2.3 The estimation of precision in this practice is based ontypical formulations for rigid and flexible foams. Formulationswith faster reaction times will likely have g
17、reater variability,particularly cream time (initiation time). Formulations withslower reaction times will likely have greater variability in themeasurement of free rise time.5.2.4 It is possible that low-level (ppm, ppb) ingredientcontamination will not be detectable using this practice.Confirmation
18、 of such contamination will potentially requirelarge-scale ( 20 litres) tests and is out of the scope of thispractice.6. Apparatus6.1 Stirrer for Mixing:6.1.1 Stirring motor,6.1.2 Propeller or other type of mixing apparatus, and6.1.3 Stainless steel shaft.6.2 Cups6.3 KnifeCutting length of the blade
19、 must be large enoughto cleanly cut through the risen foam at the top of the cup.6.4 Thermometersaccurate to 60.5C.6.5 Stopwatchcapable of measuring to 0.1 s.6.6 Balancecapacity of 100 g and capable of weighing to0.1 g.6.7 Tachometercapable of measuring to the nearest rpm.6.8 Rulercapable of measuri
20、ng to 1 mm.7. Test Conditions7.1 Since isocyanates react with moisture, keep laboratoryhumidity low, preferably around 50 % relative humidity.7.2 Some of the parameters are influenced by atmosphericpressure. The quantitative influence is not known at this time.If results are to be compared between l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD74872013E19579STANDARDPRACTICEFORPOLYURETHANERAWMATERIALSPOLYURETHANEFOAMCUPTEST 聚氨酯 原材料 标准 实施 规程

链接地址:http://www.mydoc123.com/p-525637.html