《ASTM D7486-2008 752 Standard Test Method for Measurement of Fines and Dust Particles on Plastic Pellets by Wet Analysis《用湿法分析法测量塑料粒上的细粒土和粉尘颗粒的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7486-2008 752 Standard Test Method for Measurement of Fines and Dust Particles on Plastic Pellets by Wet Analysis《用湿法分析法测量塑料粒上的细粒土和粉尘颗粒的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7486 08Standard Test Method forMeasurement of Fines and Dust Particles on Plastic Pelletsby Wet Analysis1This standard is issued under the fixed designation D 7486; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method measures the amount of fine particlesadhered on plastic pellets or granules in which they ar
3、ecommonly produced and supplied. The lower limit of this testmethod is restricted only by the porosity of the filter disc usedto capture the particle size being quantified.1.2 The wet analysis technique allows for separation andcollection of statically charged particles by liquid wash andfiltration
4、methods. This must be performed under standardlaboratory conditions.1.3 The values stated in SI units are to be regarded asstandard.1.4 This test method describes an essential practice to checkthe quality of plastics once the production cycle is terminatedand to evaluate the performance of pellet cl
5、eaning systems orof the special pneumatic conveying systems for the distinct sizefractions below 500 micron only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate sa
6、fety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D 1921 Test Methods for Particle Size (Sieve Analysis) ofPlastic MaterialsE11 Specification for Wire Cl
7、oth and Sieves for TestingPurposes2.2 FEM Standards:3FEM 2482 Test Method to Determine Content of Fines andStreamers in Plastic Pellets.3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 finesfines (Dust) are small particles of plastic whichhave been torn away from the original p
8、ellet by contact with arough surface and friction at high conveying velocities. Theyare defined as the particle fraction with a particle size up to2000 m.3.1.2 streamersstrings of plastics of various lengths thatare created when the resin travels through pneumatic convey-ing lines at high velocity.
9、Streamers are also known as angelhair, foil, floss, film or snake skin.4. Summary of Test Method4.1 Fines or streamers, or both, are generated in polymerresins during pneumatic conveying. Fines and streamers areknown to cause problems in plastic producing and processingplants by clogging the transpo
10、rting and procession lines. Onfinished products, fines cause the formation of gel, contamina-tion, surface imperfection and weak spots.4.2 The streamer content for a particle size considerablylarger than the pellet diameter are determined by dry screeningaccording to Test Method D 1921.4.3 The funda
11、mental principle used in this document isbased upon the condition that statically charged fines normallyadhering to plastic pellets be removed by rinsing the testsample with a washing liquid, causing fines in the sample towash away into a container. These particles are then pouredinto a filter funne
12、l to separate the fines from the washing liquid.The weight of the filter paper is accurately measured beforeand after the collection process, and used to calculate the PPMlevel for that sample.4.4 Wet analysis quantifies the amounts of dust with particlesizes typically from 1.6 to 500 microns.5. Sig
13、nificance and Use5.1 Molding and extruding plastic pellets require dust free,dry pellets to prevent processing problems. Plastic producers1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current
14、 edition approved Nov. 1, 2008. Published November 2008.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Avai
15、lable from European Federation of Materials Handling, Diamant Building,80 Boulevard Auguste Reyers B, 1030 Brussels, Belgium, http:/www.fem-.TABLE 1 Comparison of Typical Particle Sizes MeasuredType Lower Limit Upper Limit Test MethodD 1921 500 m 2000 m dryD 7486 1.6 mA500 m wetAThe lower limit is s
16、et by the porosity of the filter disk.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.try to remove the dust and streamers with dust removal systemsprior to packaging and loading. How to accurately measuredust and streamer content in
17、 plastic pellets is an importantquality control issue.5.2 Particle size analysis is used to determine a percentageof particle size distribution from a representative sample of thewhole. In terms of size analysis concerning plastic pellets,sieving is used to determine the dust content in the range of
18、 500to 2000 micron. Test Method D 1921, Test Method B, is usedto determine this type of particle sizing.5.3 After dry sieve analysis, particles smaller than 500microns need to be analyzed by wet method. A fresh sampleshall be used for wet analysis. This test method allows washingdown the fines attac
19、hed to the pellets by electrostatic forces.5.4 The wet analysis provides accurate quantification ofsmall to large amounts of fines, negating static effects, andeliminating detrimental effects of mechanical agitation. A wetanalysis must be employed to accurately quantify lower PPMdust levels in plast
20、ic pellets.6. Interferences6.1 Filtration paper has to be made of glass microfibermaterial. Paper filter fibers swell, reducing filtration speed andincreasing filtration time.6.2 Glass microfiber filters are fragile. Care must be takenwhen handling the wet filter to keep tears from being produced.6.
21、3 Some plastics contain certain additives that dissolve inwashing liquids. This creates a particulate cloud of the washingliquid, clogs the filter paper, and gives inaccurate weightresults.6.4 When analyzing material that reacts with heat (lowmelting temperature), a lower drying temperature is requi
22、red.6.5 Too much material on a sieve causes mass blinding.Pellet bed depth has to be kept to no more than two pelletsdeep.6.6 Replace the water and clean supply hoses on a regularbasis. Algae or slime can develop and skew test results.6.7 Discard sieves if the wire-cloth is damaged or no longertaut,
23、 as they no longer conform to Specification E11.6.8 Use a non-stick, high temperature surface for the ovenracks. The glass microfiber filter discs stick to the metal ovenrack during the drying process.7. Apparatus7.1 The function of the apparatus (see Fig. 1) is to separateall fines below 500 micron
24、 from the pellets of the productsample to be tested. The apparatus runs with a washing liquidin recirculation mode.7.2 The apparatus consists of a wash beaker with spray hoseand nozzle, a filter funnel, a water tank reservoir with drain, apump with throttle valve and flow meter, and connectingpiping
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD74862008752STANDARDTESTMETHODFORMEASUREMENTOFFINESANDDUSTPARTICLESONPLASTICPELLETSBYWETANALYSIS

链接地址:http://www.mydoc123.com/p-525632.html