《ASTM D7392-2007 Standard Practice for PM Detector and Bag Leak Detector Manufacturers to Certify Conformance with Design and Performance Specifications for Cement Plants《PM探测器和袋子检漏.pdf》由会员分享,可在线阅读,更多相关《ASTM D7392-2007 Standard Practice for PM Detector and Bag Leak Detector Manufacturers to Certify Conformance with Design and Performance Specifications for Cement Plants《PM探测器和袋子检漏.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7392 07Standard Practice forPM Detector and Bag Leak Detector Manufacturers toCertify Conformance with Design and PerformanceSpecifications for Cement Plants1This standard is issued under the fixed designation D 7392; the number immediately following the designation indicates the year
2、 oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the procedure for certifying par-t
3、iculate matter detectors (PMDs) and bag leak detectors(BLDs) that are used to monitor particulate matter (PM)emissions from kiln systems at Portland cement plants thatburn hazardous waste. It includes design specifications, perfor-mance specifications, test procedures, and information require-ments
4、to ensure that these continuous monitors meet minimumrequirements, necessary in part, to monitor reliably PM con-centrations to indicate the need for inspection or correctiveaction of the types of air pollution control devices that are usedat Portland cement plants that burn hazardous waste.1.2 This
5、 practice applies specifically to the original manu-facturer, or to those involved in the repair, remanufacture, orresale of PMDs or BLDs.1.3 This practice applies to (a) wet or dry process cementkilns equipped with electrostatic precipitators, and (b) dryprocess kilns, including pre-heater pre-calc
6、iner kiln systems,equipped with fabric filter controls. Some types of monitoringinstruments are suitable for only certain types of applications.NOTE 1This practice has been developed based on careful consider-ation of the nature and variability of PM concentrations, effluent condi-tions, and the typ
7、e, configuration, and operating characteristics of airpollution control devices used at Portland cement plants that burnhazardous waste.1.4 This practice applies to Portland cement kiln systemssubject to PM emission standards contained in 40 CFR 63,Subpart EEE.NOTE 2The level of the PM emission limi
8、t is relevant to the designand selection of appropriate PMD and BLD instrumentation. The currentpromulgated PM emission standards (70 FR 59402, Oct. 12, 2005) are: (a)65 mg/dscm at 7 % O2(0.028 gr/dscf at 7 % O2) or approximately 30mg/acm (0.013 gr/acf) for “existing sources” and (b) 5.3 mg/dscm at
9、7 %O2(0.0023 gr/dscf at 7 % O2) or approximately 2.5 mg/acm (0.001 gr/acf)for “new sources.” On March 23, 2006 (71 FR 14665) EPA proposed torevise the PM standard for new cement plants to 15.9 mg/dscm at 7 %O2(0.0069 gr/dscf at 7 % O2), or about 6-9 mg/acm (0.0026-0.0039gr/acf). The emission standar
10、ds may change in future rulemakings, sousers of this practice should check the current regulations. Some types ofmonitoring instruments are not suitable for use over the range of emissionsencountered at both new and existing sources.1.5 The specifications and test procedures contained in thispractic
11、e exceed those of the United States EnvironmentalProtection Agency (USEPA). For each monitoring device thatthe manufacturer demonstrates conformance to this practice,the manufacturer may issue a certificate that states thatmonitoring device conforms with all of the applicable designand performance r
12、equirements of this practice and also meetsall applicable requirements for PMDs or BLDs at 40 CFR 63,Subpart EEE, which apply to Portland cement plants.NOTE 340 CFR 63.1206 (c)(8) and (9) requires that BLDs and PMDs“be certified by the manufacturer to be capable of detecting particulatematter emissi
13、ons at concentrations of 1.0 milligrams per actual cubicmeter unless you demonstrate under 63.1209(g), that a higher detectionlimit would routinely detect particulate matter loadings during normaloperations.” This practice includes specific procedures for determinationand reporting of the detection
14、limit for each PMD or BLD model.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitati
15、ons prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 6216 Practice for Opacity Monitor Manufacturers toCertify Conformance with Design and Performance Speci-ficationsD 6831 Test Method for Sampling and Determining Par-ticulat
16、e Matter in Stack Gases Using an In-Stack, InertialMicrobalance2.2 U.S. Environmental Protection Agency Documents1This practice is under the jurisdiction of ASTM Committee D22 Air Qualityand is the direct responsibility of Subcommittee D22.03 Ambient Atmospheres andSource Emissions.Current edition a
17、pproved Oct. 1, 2007. Published November 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM
18、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.40 CFR 63, Subpart EEE National Emission Standards forHazardous Air Pollutants: Final Standards for HazardousAir Pollutants for Hazardous Waste Combustors2.3 Other Documents3ISO/DIS 9004 Quality Manag
19、ement and Quality SystemElements-GuidelinesANSI/NCSL Z 540-1-1994 Calibration Laboratories andMeasuring Equipment - General Requirements3. Terminology3.1 For terminology relevant to this practice, see Terminol-ogy D 1356.3.1.1 Definitions for transmittance measurement equipment(that is, opacity moni
20、tors) are provided in Practice D 6216.3.2 Definitions of Terms Specific to This Standard:Analyzer Equipment3.2.1 bag leak detector BLD, nan instrument installeddownstream of a fabric filter control device that interacts witha PM-laden effluent stream and produces an output signal ofsufficient accura
21、cy and repeatability to track changes in PMcontrol device performance and, together with appropriate dataanalysis, indicates the need to inspect the fabric filter asreferenced in the Federal Register, 40 CFR 63, Subpart EEE.BLDs are used to track rapid changes in PM concentration andmust have suffic
22、ient dynamic range to track both “peaks” andbaseline PM levels and include provisions for adjusting theaveraging period, alarm delay, and alarm set point appropriatefor source-specific conditions. BLDs must also include provi-sions to detect faults or malfunctions of the measurementsystem.3.2.2 part
23、iculate matter detector PMD, nan instrumentthat interacts with a PM-laden effluent stream and produces anoutput signal of significant accuracy and repeatability so as toindicate significant changes in the concentration of particulatematerial entrained in the effluent downstream of an electro-static
24、precipitator or fabric filter as referenced in the FederalRegister, 40 CFR 63, Subpart EEE. PMDs are used to trackchanges in PM concentrations using six-hour rolling averages,updated each hour with a new one-hour block average. PMDsmust also include provisions to activate an alarm and detectfaults o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73922007STANDARDPRACTICEFORPMDETECTORANDBAGLEAKDETECTORMANUFACTURERSTOCERTIFYCONFORMANCEWITHDESIGNANDPERFORMANCESPECIFICATIONSFORCEMENTPLANTSPM

链接地址:http://www.mydoc123.com/p-525346.html