《ASTM D7284-2013 3750 Standard Test Method for Total Cyanide in Water by Micro Distillation followed by Flow Injection Analysis with Gas Diffusion Separation and Amperometric Detect.pdf》由会员分享,可在线阅读,更多相关《ASTM D7284-2013 3750 Standard Test Method for Total Cyanide in Water by Micro Distillation followed by Flow Injection Analysis with Gas Diffusion Separation and Amperometric Detect.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7284 13Standard Test Method forTotal Cyanide in Water by Micro Distillation followed byFlow Injection Analysis with Gas Diffusion Separation andAmperometric Detection1This standard is issued under the fixed designation D7284; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to determine the concent
3、rationof total cyanide in an aqueous wastewater or effluent. Themethod detects the cyanides that are free (HCN and CN-) andstrong-metal-cyanide complexes that dissociate and releasefree cyanide when refluxed under strongly acidic conditions.1.2 This method may not be applicable to process solutionsf
4、rom precious metals mining operations.1.3 This procedure is applicable over a range of approxi-mately 2 to 500 g/L (parts per billion) total cyanide. Higherconcentrations can be measured with sample dilution or lowerinjection volume.1.4 The determinative step of this method utilizes flowinjection wi
5、th amperometric detection based on Test MethodD6888. Prior to analysis, samples must be distilled with amicro-distillation apparatus described in this test method orwith a suitable cyanide distillation apparatus specified in TestMethods D2036.1.5 The values stated in SI units are to be regarded asst
6、andard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the ap
7、plica-bility of regulatory limitations prior to use. Specific hazardstatements are given in 8.6 and Section 9.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2036 Test Methods for Cyanides in WaterD2777 Practice for Determination of
8、 Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3856 Guide for Management Systems in LaboratoriesEngaged in Analysis of WaterD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisD6696 Guide for Understanding Cyanide SpeciesD6888
9、 Test Method for Available Cyanide with LigandDisplacement and Flow InjectionAnalysis (FIA) UtilizingGas Diffusion Separation and Amperometric DetectionD7365 Practice for Sampling, Preservation and MitigatingInterferences in Water Samples for Analysis of CyanideE691 Practice for Conducting an Interl
10、aboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminology D1129 and Guide D6696.3.2 Definitions of Terms Specific to This Standard:3.2.1 total cyanideTotal cyanide is an analytically definedter
11、m that refers to the sum total of all of the inorganic chemicalforms of cyanide that dissociate and release free cyanide whenrefluxed under strongly acidic conditions. Total cyanide isdetermined analytically through strong acid distillation or UVradiation followed by analysis of liberated free cyani
12、de onaqueous samples preserved with NaOH (pH12). In water,total cyanide includes the following dissolved species: freecyanide, weak acid dissociable metal cyanide complexes andstrong metal cyanide complexes. Also, some of the strongmetal cyanide complexes, such as those of gold, cobalt andplatinum,
13、might not be fully recovered during the total cyanideanalytical procedure. Additionally, total cyanide may alsoinclude some organic forms of cyanide such as nitriles thatrelease free cyanide under the conditions of the analysis.1This test method is under the jurisdiction of ASTM Committee D19 on Wat
14、erand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved June 15, 2013. Published July 2013. Originallyapproved in 2008. Last previous edition approved in 2008 as D7284 081. DOI:10.1520/D7284-13.2For referenced ASTM stan
15、dards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, P
16、A 19428-2959. United States14. Summary of Test Method4.1 The samples are distilled with a strong acid in thepresence of magnesium chloride catalyst and captured insodium hydroxide absorber solution.4.2 The absorber solution is introduced into a flow injectionanalysis (FIA) system where it is acidifi
17、ed to form hydrogencyanide (HCN). The hydrogen cyanide gas diffuses through ahydrophobic gas diffusion membrane, from the acidic donorstream into an alkaline acceptor stream.4.3 The captured cyanide is sent to an amperometric flow-cell detector with a silver-working electrode. In the presence ofcyan
18、ide, silver in the working electrode is oxidized at theapplied potential. The anodic current measured is proportionalto the concentration of cyanide.4.4 Calibrations and data are processed with the instru-ments data acquisition software.5. Significance and Use5.1 Cyanide and hydrogen cyanide are hig
19、hly toxic. Regu-lations have been established to require the monitoring ofcyanide in industrial and domestic wastes and surface waters.35.2 This test method is applicable for natural waters, indus-trial wastewaters and effluents.6. Interferences6.1 Improper sample collection or pretreatment can resu
20、lt insignificant positive or negative bias, therefore it is imperativethat samples be collected and mitigated for interferences asdescribed in Practice D7365.6.1.1 Sulfide captured in the absorber solution above 50-mg/L S2-will diffuse through the gas diffusion membraneduring flow injection analysis
21、 and can be detected in theamperometric flowcell as a positive response. Refer to Section11.2 for sulfide abatement.6.1.2 Thiocyanate in the presence of oxidants (for example,nitrates, hydrogen peroxide, chlorine or chloramine, Carosacid), can decompose to form cyanide during the distillationresulti
22、ng in positive interference regardless of the determina-tive step (amperometry, colorimetry, etc.). During acidicdistillation, decomposition of thiocyanate in the absence ofoxidants produces elemental sulfur, sulfur(IV) oxide, as well ascarbonyl sulfide which eventually leads to the formation ofsulf
23、ite ion (SO32-) in the NaOH absorbing solution. The sulfiteion slowly oxidizes cyanide to cyanate resulting in a negativeinterference. Therefore, samples that are known to containsignificant amounts of thiocyanate may need to be analyzedwith a method that does not require distillation, for example,a
24、vailable cyanide by Test Method D6888.6.1.2.1 During the validation study, synthetic samples con-taining up to 15 mg/LSCN-and 25 mg/LNO3as N yielded lessthan 0.5 % of the SCN-to be measurable CN-. For example, asolution that did not contain any known amount of cyanide, butdid contain 15-mg/L SCN-and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD728420133750STANDARDTESTMETHODFORTOTALCYANIDEINWATERBYMICRODISTILLATIONFOLLOWEDBYFLOWINJECTIONANALYSISWITHGASDIFFUSIONSEPARATIONANDAMPEROMETRICDETECTPDF

链接地址:http://www.mydoc123.com/p-525048.html