《ASTM D6807-2002(2009) 459 Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from2 to 100 S cm《反向渗透率为2-100 S cm的连.pdf》由会员分享,可在线阅读,更多相关《ASTM D6807-2002(2009) 459 Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from2 to 100 S cm《反向渗透率为2-100 S cm的连.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6807 02 (Reapproved 2009)Standard Test Method forOperating Performance of Continuous ElectrodeionizationSystems on Reverse Osmosis Permeates from2 to 100 S/cm1This standard is issued under the fixed designation D 6807; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the oper-a
3、ting characteristics of continuous electrodeionization (CEDI)devices, indicative of deionization performance when a deviceis applied to production of highly deionized water from theproduct water of a reverse osmosis system. This test method isa procedure applicable to feed waters containing carbonic
4、 acidand/or dissolved silica and other solutes, with a conductivityrange of approximately 2 to 100 microsiemens-cm-1.1.2 This test method covers the determination of operatingcharacteristics under standard test conditions of CEDI deviceswhere the electrically active transfer media therein is predomi
5、-nantly regenerated.1.3 The test method is not necessarily indicative of:1.3.1 Long term performance on feed waters containingfoulants and/or sparingly soluble solutes;1.3.2 Performance on feeds of brackish water, sea water, orother high salinity feeds;1.3.3 Performance on synthetic industrial feed
6、solutions,pharmaceuticals, or process solutions of foods and beverages;or,1.3.4 Performance on feed waters less than 2 S/cm, par-ticularly performance relating to organic solutes, colloidal orparticulate matter, or biological or microbial matter.1.4 The test method, subject to the limitations descri
7、bed,can be applied as either an aid to predict expected deionizationperformance for a given feed water quality, or as a method todetermine whether performance of a given device has changedover some period of time. It is ultimately, however, the usersresponsibility to ensure the validity of the test
8、method for theirspecific applications.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard may involve hazardous materials, opera-tions, and equipment. This standard does not purport toaddress all of the safety
9、concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 513 Test Methods for Total and Diss
10、olved Carbon Diox-ide in WaterD 859 Test Method for Silica in WaterD 1125 Test Methods for Electrical Conductivity and Re-sistivity of WaterD 1129 Terminology Relating to WaterD 1293 Test Methods for pH of WaterD 2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Comm
11、ittee D19 on WaterD 4194 Test Methods for Operating Characteristics of Re-verse Osmosis and Nanofiltration Devices3. Terminology3.1 DefinitionsFor definitions of general terms used inthese test methods, refer to Terminology D 1129.3.2 For descriptions of terms relating to reverse osmosis,refer to Te
12、st Methods D 4194.3.3 Definitions of Terms Specific to This Standard:3.3.1 cellan independently fed chamber formed by twoadjacent ion exchange membranes, or by a membrane and anadjacent electrode.3.3.2 continuous electrodeionization (CEDI) devicea de-vice that removes ionized and ionizable species f
13、rom liquidsusing electrically active media and using an electrical potentialto influence ion transport, where the ionic transport propertiesof the active media are a primary sizing parameter. CEDIdevices typically comprise semi-permeable ion exchangemembranes and permanently charged ion exchange med
14、ia.Examples include continuous deionization, electrodiaresis, andpacked-bed or filled-cell electrodialysis.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.08 on Membranes and IonExchange Materials.Current edition approved
15、 May 1, 2009. Published June 2009. Originallyapproved in 2002. Last previous edition approved in 2002 as D 6807 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to t
16、he standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.3.3 current effciencythe ratio, expressed in percent, ofthe net transfer of ionized and ionizable solutes per unit cellwithin a C
17、EDI device, expressed in chemical equivalentstransferred per unit time, to the number of coulombs trans-ferred from an external DC power source to each electrodepair, expressed in faradays per unit time. Calculation of currentefficiency is described in 9.2.4. Summary of Test Method4.1 This test meth
18、od is used to determine performancecapabilities of CEDI devices with regard to extent of ionremoval, pressure/flow relationships and electrical power con-sumption at standard or nominal operating conditions, electri-cal current characteristics, and the relative ability of the deviceto remove ionized
19、 and ionizable species when fed reverseosmosis permeate water. On this type of feed, there is consid-erable water splitting and ion-exchange resin regeneration,causing certain species to become ionized within the device,either by the electromotive force or a localized pH shift. Themethod is applicab
20、le to both new and used devices.4.2 Pressure loss data is obtained. This information providesinformation relating to possible particulate plugging, fouling,or internal damage of the device. Deionization performance,extent of silica and dissolved carbon dioxide removal, concen-trating stream pH, and
21、applied voltage are determined at apredetermined level of electrical current transfer. The ohmic(electrical) resistance is determined. This information in com-bination with concentrating stream pH provides basic designand performance information.5. Significance and Use5.1 CEDI devices can be used to
22、 produce deionized waterfrom feeds of pretreated water. This test method permits themeasurement of key performance capabilities of CEDI devicesusing a standard set of conditions. The data obtained can beanalyzed to provide information on whether changes may haveoccurred in operating characteristics
23、of the device indepen-dently of any variability in feed water characteristics oroperating conditions. Under specific circumstances, the methodmay also provide sufficient information for plant design.6. Apparatus6.1 Description:6.1.1 The test apparatus is schematically represented in Fig.1. Feed wate
24、r to the apparatus may be passed through a heatexchanger and/or other accessories to modify and/or controlfeed water temperature as desired. Alternately, data obtainedfrom the operation of the apparatus may be normalized fortemperature if normalization factors are known.6.1.2 Feed water to the appar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD680720022009459STANDARDTESTMETHODFOROPERATINGPERFORMANCEOFCONTINUOUSELECTRODEIONIZATIONSYSTEMSONREVERSEOSMOSISPERMEATESFROM2TO100SCM

链接地址:http://www.mydoc123.com/p-523636.html