ASTM D6745-2006 Standard Test Method for Linear Thermal Expansion of Electrode Carbons《电极碳线性热膨胀率的标准测试方法》.pdf
《ASTM D6745-2006 Standard Test Method for Linear Thermal Expansion of Electrode Carbons《电极碳线性热膨胀率的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6745-2006 Standard Test Method for Linear Thermal Expansion of Electrode Carbons《电极碳线性热膨胀率的标准测试方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6745 06An American National StandardStandard Test Method forLinear Thermal Expansion of Electrode Carbons1This standard is issued under the fixed designation D 6745; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the coef-ficient of linear thermal expansion (CTE) for carbon
3、anodesand cathodes used in the aluminum industry, in baked form, byuse of a vitreous silica dilatometer.1.2 The applicable temperature range for this test methodfor research purposes is ambient to 1000C. The recommendedmaximum use temperature for product evaluation is 500C.1.3 This test method and p
4、rocedure is based on Test MethodE 228, which is a generic all-encompassing method. Specificsdictated by the nature of electrode carbons and the purposes forwhich they are used are addressed by this procedure.1.4 Electrode carbons in the baked form will only exhibitprimarily reversible dimensional ch
5、anges when heated.1.5 The values stated in SI units are to be regarded asstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and d
6、etermine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 228 Test Method for Linear Thermal Expansion of SolidMaterials With a Push-Rod Dilatometer3. Terminology3.1 Definitions:3.1.1 linear thermal expansionthe change in length perunit length re
7、sulting from a temperature change. Linear ther-mal expansion is symbolically represented by DL/L0, where DLis the length change of the specimen (L1L0), L0and L1are thespecimens lengths at reference temperature T0and test tem-perature T1, respectively. Linear thermal expansion is oftenexpressed as a
8、percentage or in parts per million (such asm/m).3.1.2 mean coeffcient of linear thermal expansion (CTE)The linear thermal expansion per change in temperature; themean coefficient of linear thermal expansion is represented by:aT15DL/L0DT51L0DLDT51L0L12 L0T12 T0(1)3.1.2.1 This has to be accompanied by
9、 the values of the twotemperatures to be meaningful; the reference temperature (T0)is 20C, and the notation may then only contain a singlenumber, such as a200, meaning the mean coefficient of linearthermal expansion between 20 and 200C.3.2 Definitions of Terms Specific to This Standard:3.2.1 referen
10、ce specimena particularly identified or pedi-greed material sample, with well-characterized behavior andindependently documented performance.3.2.2 specimena representative piece of a larger body(anode, cathode, and so forth) that is considered to be fairlytypical of a portion or of the entire piece.
11、3.2.3 vitreous silica dilatometera device used to deter-mine linear thermal expansion, by measuring the difference inlinear thermal expansion between a test specimen and thevitreous silica parts of the dilatometer.4. Summary of Test Method4.1 Arepresentative specimen is placed into a vitreous silica
12、dilatometer and heated, while its linear expansion is continu-ously recorded. The change of the specimen length is recordedas a function of temperature. The coefficient of linear thermalexpansion is then calculated from these recorded data.5. Significance and Use5.1 Coefficients of linear thermal ex
13、pansion are used fordesign and quality control purposes and to determine dimen-sional changes of parts and components (such as carbonanodes, cathodes, and so forth) when subjected to varyingtemperatures.6. Apparatus6.1 DilatometerThe dilatometer consists of the following:1This test method is under t
14、he jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved Jan. 1, 2006. Published February 2006. Originallyapproved in 2001. Last previous editio
15、n approved in 2001 as D 674501.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International,
16、 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.1.1 Specimen Holder and Push-rod, both made of vitreoussilica. The design of the device shall ensure that the push-rodload on the specimen by itself is not causing deformation. Theuse of pressure distribution quar
17、tz plates on top of thespecimen is permissible.NOTE 1Dilatometers are usually constructed in horizontal or verticalconfigurations (1)3Vertical devices are preferred for very large samplesand when extensive shrinkage is expected. Horizontal configurationsusually afford better temperature uniformity o
18、ver the specimen, but aresubject to drooping when large specimens are employed. Horizontaldevices, when used with very large specimens, require special provisionsto reduce friction between the specimen and the dilatometer tube tominimize push-rod pressure required to keep the specimen in contact wit
19、hthe end plate. For this application, either configuration is acceptable.NOTE 2For basic construction details and fused silica annealingschedule, consult Test Method E 228.NOTE 3Multiple rods supporting a platform in place of large diametertubes have been also used successfully in the vertical confi
20、guration.6.1.2 Transducer or Indicator, for measuring the differencein length between the specimen and the dilatometer with anaccuracy within 6 2 m. The transducer shall translate thesemovements into an electrical signal suitable for displaying orrecording. The non-linearity of this conversion must
21、be lessthan 0.25 % of the full scale value of the output.The transducershall be protected or mounted so that the maximum tempera-ture change observed in the transducer during a test will affectthe transducer readings by less than 1 m.6.1.3 Temperature Sensors, for determining the mean tem-perature o
22、f the specimen with an accuracy within 6 0.5C.When a thermocouple is used, it shall be referenced (coldjunction compensated) to the ice point with an ice-water bathor an equivalent system.6.1.3.1 Due to the large size of the specimen, a minimum ofone thermocouple per 40 mm specimen length must beemp
23、loyed. It is permissible to read the output of each thermo-couple independently and average the readings or to connectthem in series and divide the single reading by the number ofthermocouples to obtain the average. In the latter case, inter-connections must be made at or beyond the point of coldjun
24、ction compensation.6.1.3.2 The temperature sensors shall be in close proximityto the specimen, preferably in between the quartz dilatometertube and the specimen. The temperature sensors shall not bedirectly exposed to the furnace walls.6.2 Readout or Recording of Data:6.2.1 Manual recording of expan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD67452006STANDARDTESTMETHODFORLINEARTHERMALEXPANSIONOFELECTRODECARBONS 电极 线性 膨胀率 标准 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-523413.html