ASTM D6535 D6535M-2005(2010)e1 0625 Standard Test Method for Determining the Dip Tube Length of a Mechanical Pump Dispenser《测定机械泵分配器汲取管长度的标准试验方法》.pdf
《ASTM D6535 D6535M-2005(2010)e1 0625 Standard Test Method for Determining the Dip Tube Length of a Mechanical Pump Dispenser《测定机械泵分配器汲取管长度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6535 D6535M-2005(2010)e1 0625 Standard Test Method for Determining the Dip Tube Length of a Mechanical Pump Dispenser《测定机械泵分配器汲取管长度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6535/D6535M 05 (Reapproved 2010)1Standard Test Method forDetermining the Dip Tube Length of a Mechanical PumpDispenser1This standard is issued under the fixed designation D6535/D6535M; the number immediately following the designation indicates theyear of original adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was editorially revised in December 2010.1. Scope1.1 This test method covers th
3、e determination technique fora dip tube of a mechanical pump dispenser.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other.
4、Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and
5、 determine the applica-bility of regulatory limitations prior to use.2. Significance and Use2.1 This test method is to be used to determine the length ofa dip tube of a mechanical pump dispenser that extends to thebottom-corner of a container.2.2 This test method is to be used to determine the lengt
6、h ofa dip tube of a mechanical pump dispenser that extends to thebottom-center of a container.3. Apparatus3.1 Thin Metal Ruler, with minimum gradients of onemillimeter and/or116 in. along with a zero index at the end ofthe ruler.3.2 Calipers.4. ProcedureTEST METHOD “A”DIP TUBE LENGTHDETERMINATION TO
7、 THE BOTTOM-CORNER OFTHE CONTAINERNOTE 1This test method is used when the dip tube of a mechanicalpump dispenser must extend to the bottom-corner of a container.4.1 Place the zero-index end of the ruler into the containeras shown in Fig. 1.4.2 Turn the ruler so that the side of the ruler reaches as
8、farinto the bottom-corner of the container as possible.NOTE 2If the cross-sectional area of the container is not round,position the ruler into the farthest bottom-corner of the container.4.3 Adjust the ruler so that it is positioned through thecenter axis of the container opening.4.4 Measure the dip
9、 tube length to within 1 mm or116 in. Ifthe measurement value is between the whole millimetre or116thgradient, use the larger value (that is, if measurement is 118.5mm, use 119 mm; or if measurement is 4-2132 in., use 4-1116in).4.5 If the dip tube measurement is in millimetres, subtract 1mm from the
10、 measured value. If the dip tube measurement is ininches, subtract116 in. from the measured value.4.6 Record the net value (original value minus 1 mm or116in.).4.7 To verify the new dip tube specification, prepare asample mechanical pump dispenser with the newly-specifieddip tube length.4.8 Secure t
11、he mechanical pump dispenser to the container.4.9 Verify that the end of the dip tube is not closed-off bythe bottom or side of the container.4.10 To specify the exposed dip tube length, measure thelength of the exposed body as per dimension “Y” of Fig. 2 andsubtract from the overall length as speci
12、fied in 4.6.NOTE 3If the container is not transparent, a section of the bottom ofthe container may need to be removed so that the position of the end of thedip tube may be viewed.TEST METHOD “B”DIP TUBE LENGTHDETERMINATION TO THE BOTTOM-CENTER OFTHE CONTAINERNOTE 4This test method is used when the d
13、ip tube of a mechanicalpump dispenser must extend to the bottom-center of a container.4.11 Place the zero-index end of the ruler into the containeras shown in Fig. 3.1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.33
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6535D6535M20052010E10625STANDARDTESTMETHODFORDETERMININGTHEDIPTUBELENGTHOFAMECHANICALPUMPDISPENSER

链接地址:http://www.mydoc123.com/p-522781.html