《ASTM D6490-1999(2006) Standard Test Method for Water Vapor Transmission of NonFilm Forming Treatments Used on Cementitious Panels《水泥粘合板用无膜成型处理的水蒸气传输的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6490-1999(2006) Standard Test Method for Water Vapor Transmission of NonFilm Forming Treatments Used on Cementitious Panels《水泥粘合板用无膜成型处理的水蒸气传输的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6490 99 (Reapproved 2006)Standard Test Method forWater Vapor Transmission of NonFilm Forming TreatmentsUsed on Cementitious Panels1This standard is issued under the fixed designation D 6490; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the rate atwhich water vapor passes t
3、hrough non film forming treatments,such as silanes, siloxanes and blends of silanes/siloxanesapplied to cementitious substrates.1.2 This test method covers the use of the wet cup tech-nique, which most closely approaches the exterior conditionsfor use for these materials. Other conditions can be use
4、d ifagreed upon between purchaser and supplier. Agreementshould not be expected between results obtained by differentmethods or test conditions.1.3 The values stated in SI units of measurement aredesignated as the standard. Factors for conversion to inch-pound units are given in 9.2.1.1 and 9.2.2.1.
5、1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced D
6、ocuments2.1 ASTM Standards:2D 823 Practices for Producing Films of Uniform Thicknessof Paint, Varnish, and Related Products on Test PanelsD 1193 Specification for Reagent WaterD 1734 Practice for Making Cementitious Panels for Test-ing CoatingsD 3924 Specification for Environment for Conditioning an
7、dTesting Paint, Varnish, Lacquer, and Related MaterialsE 104 Practice for Maintaining Constant Relative Humidityby Means of Aqueous Solutions3. Summary of Test Method3.1 The treated cementitious substrate is sealed to the openmouth of an assembly containing water with the treated sidefacing the wate
8、r, and the assembly placed in a test chamberwith a controlled atmosphere maintained at 50 6 5 % relativehumidity at 23 6 2C (73.5 6 3.5F). Periodic weighings ofthe assembly are made to determine the rate of water vapormovement through the specimen.4. Significance and Use4.1 One of the factors affect
9、ing the performance providedby a cementitious treatment is how readily water vapor passesthrough it. Hence, the water vapor transmission characteristicsof treatments are important in assessing their performance inpractical use.4.2 The purpose of this test method is to obtain values ofwater vapor tra
10、nsfer through treatments that range in perme-ability from high to low. These values are for use in design,manufacture, and marketing.4.3 Water vapor transmission is not a linear function of filmthickness, temperature or relative humidity.4.4 Values of water vapor transmission rate (WVT) andwater vap
11、or permeance (WVP) can be used in the relativerating of treatments only if the treatments are tested under thesame closely controlled conditions of temperature and relativehumidity.5. Apparatus5.1 Assembly, consisting of a container, typically with anopening of approximately 75 mm (3 in.) by 150 mm
12、(6 in.).The depth of the dish is such that there is a 20 6 5 mm (0.8 60.2 in.) distance between the water surface and the surface of1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials and Applications and is the direct responsibility ofSubcommitt
13、ee D01.47 on Concrete, Stone and Masonry Treatments.Current edition approved June 1, 2006. Published June 2006. Originallyapproved in 1999. Last previous edition approved in 1999 as D 6490 - 99.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at s
14、erviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the under surface of the test specimen, with a water
15、 depth of atleast 5 mm (0.2 in.). The assembly should be made of anoncorroding material, impermeable to water or water vapor inorder to be found acceptable. The treated cementitious sub-strate can be sealed with wax or sealant to the assembly. If theassembly is made of aluminum, it must be anodized
16、or given aprotective clear coating to prevent corrosion.5.2 Test Chamber, with a controlled temperature and rela-tive humidity as specified in Section 3. Air shall be circulatedthroughout the chamber to maintain uniform conditions at alltest locations.NOTE 1For maintaining constant relative humiditi
17、es other than thosespecified in 3.1, by means of aqueous solutions, refer to proceduresoutlined in Practice E 104.5.3 Analytical Balance, having an adequate capacity for theweight of the test assemblies and a sensitivity of 10 mg (0.0002lb).6. Reagents and Materials6.1 Purity of Water, unless otherw
18、ise indicated, reference towater shall be understood to mean reagent water conforming toType IV of Specification D 1193.6.2 Sealant, such as wax for attaching the coated panel tothe top of the test assembly. It must be highly resistant to thepassage of water vapor. It must not lose weight to, nor ga
19、inweight from the atmosphere in an amount, over the requiredperiod of time, that would affect the test results by more than2 %. It must not affect the vapor pressure in a water-filledassembly.NOTE 2Among acceptable sealants are (1) a 60:40 mixture ofmicrocrystalline wax and refined crystalline paraf
20、in wax, (2) tissueembedding wax, and (3) a 50:50 mixture of beeswax and rosin.7. Test Specimen7.1 Suggested cementitious substrates to be used should be75 by 150 by 15 mm (3 by 6 by916 in.) as outlined in PracticeD 1734. Before use, the substrates should be removed fromstorage in water, dried at 80
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD649019992006STANDARDTESTMETHODFORWATERVAPORTRANSMISSIONOFNONFILMFORMINGTREATMENTSUSEDONCEMENTITIOUSPANELS

链接地址:http://www.mydoc123.com/p-522657.html