ASTM D6194-2014 red 8287 Standard Test Method for Glow-Wire Ignition of Materials《材料辉光灯丝点火的标准试验方法》.pdf
《ASTM D6194-2014 red 8287 Standard Test Method for Glow-Wire Ignition of Materials《材料辉光灯丝点火的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6194-2014 red 8287 Standard Test Method for Glow-Wire Ignition of Materials《材料辉光灯丝点火的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6194 10D6194 14Standard Test Method forGlow-Wire Ignition of Materials1This standard is issued under the fixed designation D6194; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the minimum temperature required to ignite insulating materials using a glowing heat source. Ina preliminary fashion, th
3、is test method differentiates between the susceptibilities of different materials with respect to theirresistance to ignition due to an electrically-heated source.1.2 This test method applies to molded or sheet materials available in thicknesses ranging from 0.25 to 6.4 mm.1.3 This test method is no
4、t valid for determining the ignition behavior of complete electrotechnical equipment, since the designof the electrotechnical product influences the heat transfer between adjacent parts.1.4 This test method measures and describes the response or materials, products, or assemblies to heat and flame u
5、ndercontrolled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials,products, or assemblies under actual fire conditions.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are include
6、d in this standard.(See IEEE/ASTM SI-10 for further details.)1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicab
7、ility of regulatorylimitations prior to use. For specific precautionary statements, see Section 9.1.7 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting thesetests.NOTE 1Although this test method and IEC 60695-2-13 differ in approach
8、and in detail, data obtained using either are technically equivalent.2. Referenced Documents2.1 ASTM Standards:2D1711 Terminology Relating to Electrical InsulationE176 Terminology of Fire StandardsE220 Test Method for Calibration of Thermocouples By Comparison TechniquesE230 Specification and Temper
9、ature-Electromotive Force (EMF) Tables for Standardized ThermocouplesIEEE/ASTM SI-10 International System of Units (SI), The Modernized Metric System2.2 IEC Standard:IEC 60695-4 Fire Hazard TestingPart 4: Terminology Concerning Fire Tests3IEC 60695-2-12 Fire Hazard TestingPart 212: Glowing/Hot-Wire
10、Based Test MethodsGlow-Wire Flammability TestMethod for Materials3IEC 60695-2-13 Fire Hazard TestingSection 20: Glowing/Hot-Wire Based Test MethodsGlow-Wire Coil Ignitability TestMethod for Materials32.3 ISO Standard:4ISO 13943 Fire SafetyVocabulary1 This test method is under the jurisdiction of AST
11、M Committee D09 on Electrical and Electronic Insulating Materials and is the direct responsibility of SubcommitteeD09.21 on Fire Performance Standards.Current edition approved March 1, 2010Nov. 1, 2014. Published April 2010November 2014. Originally approved in 1997. Last previous edition approved in
12、 20082010as D6194D6194 10.08. DOI: 10.1520/D6194-10.10.1520/D6194-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM
13、website.3 Available from International Electrotechnical Commission (IEC), 3 rueRue de Varemb, Case postale 131, CH-1211, Geneva 20, Switzerland, http:/www.iec.ch.4 Use undyed, soft, strong, lightweight tissue paper weighing between 12 and 30 30 g g/mm2.This document is not an ASTM standard and is in
14、tended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the cur
15、rent versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Terminology3.1 Definitions:
16、 DefinitionsUse Terminology E176, ISO 13943, and IEC 60695-4 for definitions of terms used in this testmethod and associated with fire issues. Where differences exist in definitions, those contained in Terminology E176 shall be used.Use Terminology D1711 for definitions of terms used in this test me
17、thod and associated with electrical insulation materials.3.2 Definitions of Terms Specific to This Standard:3.2.1 glow wire, glow-wire, na wire of specified dimensions that can be controllably-heated controllably heated electricallyto determine ignitability of a material.3.2.1.1 DiscussionFig. 1 sho
18、ws a glow wire glow-wire and its positioning.3.2.2 glow-wire flammability index (GWFI), nthe highest test temperature, during three subsequent tests for a test specimenof a given thickness, at which one of the following conditions are fulfilled: a) flames or glowing of the test specimen extinguishwi
19、thin 30 s after removal of the glow-wire and there is no ignition of the wrapping tissue placed underneath the test specimen;b) there is no ignition of the test specimen.3.2.3 glow-wire ignition temperature (GWIT), nthe temperature which is 25 C (30 C 25C (30C between 900 and 960 C)960C) higher than
20、 the GWFI.3.2.4 ignition, ninitiation of combustion.3.2.4.1 DiscussionIgnition is deemed to have taken place when the first of the following occurs: sustained flaming on the test specimen surface forover 5 s, or falling particles causing the appearance of flames on a tissue paper placed underneath t
21、he test specimen.NOTE 1All dimensions in millimetres.FIG. 1 Glow-Wire and Positioning of the ThermocoupleD6194 1424. Summary of Test Method4.1 In this test method, a standardized test specimen (either square or round), is supported vertically and is exposed to electricalheating from a glow-wire set
22、at pre-determined temperatures. The minimum temperature for glow-wire ignition is assessed throughtesting at incremental temperatures.5. Significance and Use5.1 During operation of electrical equipment, including wires, resistors, and other conductors, it is possible for overheating tooccur under ce
23、rtain conditions of operation, or when malfunctions occur. When this happens, a possible result is ignition of theadjacent insulation material.5.2 This test method assesses the susceptibility of electrical insulating materials to ignition as a result of exposure to a glowingwire.5.3 This test method
24、 determines the minimum temperature required to ignite a material by the effect of a glowing heat source,under the specified conditions of test.5.4 This method is suitable, subject to the appropriate limitations of an expected precision of 615 %, to categorize materials.5.5 In this procedure, the sp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD61942014RED8287STANDARDTESTMETHODFORGLOWWIREIGNITIONOFMATERIALS 材料 辉光 灯丝 点火 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-521822.html