ASTM D5882-2016 3205 Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations《深地基低应变碰撞完整性测试的标准试验方法》.pdf
《ASTM D5882-2016 3205 Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations《深地基低应变碰撞完整性测试的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5882-2016 3205 Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations《深地基低应变碰撞完整性测试的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5882 16Standard Test Method forLow Strain Impact Integrity Testing of Deep Foundations1This standard is issued under the fixed designation D5882; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the procedure for determiningthe integrity of individual vertical or inclined piles by measur-ing and an
3、alyzing the velocity (required) and force (optional)response of the pile induced by an (hand held hammer or othersimilar type) impact device usually applied axially and perpen-dicularly to the pile head surface.This test method is applicableto long structural elements that function in a manner simil
4、ar toany deep foundation units (such as driven piles, augeured piles,or drilled shafts), regardless of their method of installationprovided that they are receptive to low strain impact testing.1.2 This standard provides minimum requirements for lowstrain impact testing of piles. Plans, specification
5、s, and/orprovisions prepared by a qualified engineer, and approved bythe agency requiring the test(s), may provide additional re-quirements and procedures as needed to satisfy the objectivesof a particular test program.1.3 The text of this standard references notes and footnoteswhich provide explana
6、tory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 All observed and calculated values sh
7、all conform to theguidelines for significant digits and rounding established inPractice D6026.1.6 The method used to specify how data are collected,calculated, or recorded in this standard is not directly related tothe accuracy to which the data can be applied in design or otheruses, or both. How on
8、e applies the results obtained using thisstandard is beyond its scope.1.7 This standard may involve hazardous materials,operations, and equipment. This standard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standar
9、d toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.NOTE 1he quality of the result produced by this test method isdependent on the competence of the personnel performing it, and thesuitability of the equipment and facilities u
10、sed. Agencies that meet thecriteria of Practice D3740 are generally considered capable of competentand objective testing/sampling/ inspection/etc. Users of this test methodare cautioned that compliance with Practice D3740 does not in itselfassure reliable results. Reliable results depend on many fac
11、tors; PracticeD3740 provides a means of evaluating some of those factors.2. Referenced Documents2.1 ASTM Standards:2D653 Terminology Relating to Soil, Rock, and ContainedFluidsD3740 Practice for Minimum Requirements for AgenciesEngaged in Testing and/or Inspection of Soil and Rock asUsed in Engineer
12、ing Design and ConstructionD6026 Practice for Using Significant Digits in GeotechnicalDataD6760 Test Method for Integrity Testing of Concrete DeepFoundations by Ultrasonic Crosshole TestingD7949 Test Methods for Thermal Integrity Profiling ofConcrete Deep Foundations3. Terminology3.1 DefinitionsExce
13、pt as defined in 3.2, the terminologyused in this test method conforms with Terminology D653.3.2 Definitions of Terms Specific to This Standard:3.2.1 pile integrity, nthe qualitative evaluation of thephysical dimensions, continuity of a pile, and consistency ofthe pile material.3.2.2 pile impedance,
14、 nthe dynamic Youngs modulus ofthe pile material multiplied by the applicable cross sectionalarea of the pile and divided by the strain wave speed.3.2.3 pulse echo method, ntest in which measurements ofthe pile head velocity and force (force measurement optional)are evaluated as a function of time.1
15、This test method is under the jurisdiction ofASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.11 on Deep Foundations.Current edition approved July 1, 2016. Published July 2016. Originally approvedin 1995. Last previous edition approved in 2013 as D5882 07(2013)
16、. DOI:10.1520/D5882-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears
17、at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.4 transient response method, ntest in which the ratioof velocity transform to force transform (force measurementrequired) are evaluated as a function of fr
18、equency.4. Significance and Use4.1 Low strain impact integrity testing provides accelerationor velocity and force (optional) data on slender structuralelements (that is, structural columns, driven concrete piles, castin place concrete piles, concrete filled steel pipe piles, timberpiles, etc.). The
19、method works best on solid concrete sections,and has limited application to unfilled steel pipe piles, H piles,or steel sheet piles. These data assist evaluation of the pilecross-sectional area and length, the pile integrity andcontinuity, as well as consistency of the pile material, althoughevaluat
20、ion is approximate. This test method will not provideinformation regarding the pile bearing capacity. It is generallyhelpful to consider the soil profile, construction method andsite records when evaluating data obtained by this method.Other useful information to consider and compare with resultsof
21、this test includes low strain integrity test results of similarpiles at the same site, concrete cylinder or core strength testresults, automated monitoring data on equipment placing theconcrete when augered piles are used, or information obtainedfrom crosshole sonic logging (Test Method D6760) or th
22、ermalintegrity profiling (Test Methods D7949) if available.4.1.1 Methods of Testing:4.1.1.1 Pulse Echo Method (PEM)The pile head motion ismeasured as a function of time. The time domain record is thenevaluated for pile integrity.4.1.1.2 Transient Response Method (TRM)The pile headmotion and force (m
23、easured with an instrumented hammer) aremeasured as a function of time. The data are evaluated usuallyin the frequency domain.5. Apparatus5.1 Apparatus for Applying Impact:5.1.1 Impact Force ApplicationThe impact may be deliv-ered by any device (for example, a hand held hammer) that willproduce an i
24、nput force pulse of generally less than 1 msduration and should not cause any local pile damage due to theimpact. A hammer with a very hard plastic tip can induce ashort input force pulse without causing local pile damage. Theimpact should be applied axially to the pile (normally on thepile head).5.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD588220163205STANDARDTESTMETHODFORLOWSTRAINIMPACTINTEGRITYTESTINGOFDEEPFOUNDATIONS 地基 应变 碰撞 完整性 测试

链接地址:http://www.mydoc123.com/p-520948.html