ASTM D5769-2004 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《用气相色谱 质谱法测定精制汽油中苯、甲苯和总芳香.pdf
《ASTM D5769-2004 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《用气相色谱 质谱法测定精制汽油中苯、甲苯和总芳香.pdf》由会员分享,可在线阅读,更多相关《ASTM D5769-2004 Standard Test Method for Determination of Benzene Toluene and Total Aromatics in Finished Gasolines by Gas Chromatography Mass Spectrometry《用气相色谱 质谱法测定精制汽油中苯、甲苯和总芳香.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5769 04An American National StandardStandard Test Method forDetermination of Benzene, Toluene, and Total Aromatics inFinished Gasolines by Gas Chromatography/MassSpectrometry1This standard is issued under the fixed designation D 5769; the number immediately following the designation i
2、ndicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determina
3、tion of benzene,toluene, other specified individual aromatic compounds, andtotal aromatics in finished motor gasoline, including gasolinescontaining oxygenated blending components, by gaschromatography/mass spectrometry (GC/MS).1.2 This test method has been tested for the followingconcentration rang
4、es, in liquid volume percent, for the follow-ing aromatics: benzene, 0.1 to 4 %; toluene, 1 to 13 %; andtotal (C6 to C12) aromatics, 10 to 42 %. The round-robin studydid not test the method for individual hydrocarbon processstreams in a refinery, such as reformates, fluid catalytic crackednaphthas,
5、and so forth, used in the blending of gasolines.1.3 Results are reported to the nearest 0.01 % for benzeneand 0.1 % for the other aromatics by liquid volume.1.4 SI units of measurement are preferred and used through-out this standard.1.5 This standard does not purport to address all of thesafety con
6、cerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to its use.2. Referenced Documents2.1 ASTM Standards:2D 1298 Practice for Density, Relat
7、ive Density (SpecificGravity), or API Gravity of Crude Petroleum and LightPetroleum Products by Hydrometer MethodD 4052 Test Method for Density and Relative Density ofLiquids by Digital Density MeterD 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 4307 Practice for Preparation
8、 of Liquid Blends for Use asAnalytical Standards3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 aromaticany hydrocarbon compound containing abenzene or naphthalene ring.3.1.2 calibrated aromatic componentthe individual aro-matic components that have a specific calibration.3.1.
9、3 cool on-column injectorin gas chromatography,adirect sample introduction system that is set at a temperature ator below the boiling point of solutes or solvent on injection andthen heated at a rate equal to or greater than the column.Normally used to eliminate boiling point discrimination oninject
10、ion or to reduce adsorption on glass liners within injec-tors, or both. The sample is injected directly into the head ofthe capillary column tubing.3.1.4 open split interfaceGC/MS interface used to main-tain atmospheric pressure at capillary column outlet and toeliminate mass spectrometer vacuum eff
11、ects on the capillarycolumn. Can be used to dilute the sample entering the massspectrometer to maintain response linearity.3.1.5 reconstructed ion chromatogram (RIC)a limitedmass chromatogram representing the intensities of ion massspectrometric currents for only those ions having particularmass to
12、charge ratios. Used in this test method to selectivelyextract or identify aromatic components in the presence of acomplex hydrocarbon matrix, such as gasoline.3.1.6 retention gapin gas chromatography, refers to adeactivated precolumn which acts as a zone of low retentionpower for reconcentrating ban
13、ds in space. The polarity of theprecolumn must be similar to that of the analytical column.3.1.7 split ratioin capillary gas chromatography, the ratioof the total flow of carrier gas to the sample inlet versus theflow of the carrier gas to the capillary column, expressed bysplit ratio 5 S1C!/C (1)wh
14、ere:S = flow rate at the splitter vent, andC = flow rate at the column outlet.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04 on Hydrocarbon Analysis.Current edition approved May 1, 2004. Pub
15、lished June 2004. Originallyapproved in 1995. Last previous edition approved in 1998 as D 576998.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docum
16、ent Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.8 total ion chromatogram (TIC)mass spectrometercomputer output representing eit
17、her the summed intensities ofall scanned ion currents or a sample of the current in the ionbeam for each spectrum scan plotted against the correspondingspectrum number. Generally, it can be correlated with a flameionization detector chromatogram.3.1.9 uncalibrated aromatic componentindividual aro-ma
18、tics for which a calibration is not available. These compo-nents are estimated from the calibration of several calibratedaromatic components.3.1.10 wall coated open tubular (WCOT)a type of capil-lary column prepared by coating or bonding the inside wall ofthe capillary with a thin film of stationary
19、 phase.4. Summary of Test Method4.1 A gas chromatograph equipped with a dimethylpolysi-loxane WCOT column is interfaced to a fast scanning massspectrometer that is suitable for capillary column GC/MSanalyses. The sample is injected either through a capillarysplitter port or a cool-on-column injector
20、 capable of introduc-ing a small sample size without overloading the column. Thecapillary column is interfaced directly to the mass spectrometeror by way of an open split interface or other appropriate device.4.2 Calibration is performed on a mass basis, using mixturesof specified pure aromatic hydr
21、ocarbons. Volume percent datais calculated from the densities of the individual componentsand the density of the sample. A multipoint calibration consist-ing of at least five levels and bracketing the expected concen-trations of the specified individual aromatics is required.Specified deuterated hyd
22、rocarbons are used as the internalstandards, for example, d6-benzene for quantitating benzene.Unidentified aromatic hydrocarbons present that have not beenspecifically calibrated for are quantitated using the calibrationof an adjacent calibrated compound and summed with the otheraromatic components
23、to obtain a total aromatic concentrationof the sample.4.3 Specified quality control mixture(s), such as syntheticquality control mixtures must be analyzed to monitor theperformance of the calibrated GC/MS system. Analysis of agasoline as a reference material is strongly recommended.5. Significance a
24、nd Use5.1 Test methods to determine benzene and the aromaticcontent of gasoline are necessary to assess product quality andto meet fuel regulations.5.2 This test method can be used for gasolines that containoxygenates (alcohols and ethers) as additives. It has beendetermined that the common oxygenat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD57692004STANDARDTESTMETHODFORDETERMINATIONOFBENZENETOLUENEANDTOTALAROMATICSINFINISHEDGASOLINESBYGASCHROMATOGRAPHYMASSSPECTROMETRY

链接地址:http://www.mydoc123.com/p-520632.html