1、Designation: D5602/D5602M 18Standard Test Method forStatic Puncture Resistance of Roofing MembraneSpecimens1This standard is issued under the fixed designation D5602/D5602M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers evaluation of the maximumstatic puncture load that roofing membrane specimens canwithstand
3、without allowing the passage of water.1.2 This laboratory test is conducted at any desired tempera-ture using sheet membrane specimens manufactured in afactory or prepared in a laboratory.1.3 Roof membrane specimens to which the test method isapplicable include bituminous built up, polymer-modifiedb
4、itumens, vulcanized rubbers, non-vulcanized polymeric, andthermoplastic materials.1.3.1 The applicability of this test method to these mem-brane specimens includes their use in vegetative roof systems.1.4 This test method is not applicable to aggregate-surfacedmembrane specimens, but it is applicabl
5、e to specimens havingfactory-applied granules.1.5 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the
6、two systems may result in non-conformancewith the standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mi
7、ne the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations
8、 issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C578 Specification for Rigid, Cellular Polystyrene ThermalInsulationD1079 Terminology Relating to Roofing and Waterproofing3. Terminology3.1 DefinitionsFor definitions of ter
9、ms used in this testmethod, refer to Terminology D1079.4. Summary of Test Method4.1 Set on a thermal insulation substrate, the roofing mem-brane test specimen is subjected for 24 h to a predeterminedstatic puncture load (that is, force) using a ball bearing havinga 10-mm 0.39-in. diameter.4.2 The pr
10、edetermined static puncture load is selected asfollows:4.2.1 In accordance with a performance requirement givenin a standard specification in which this test method is cited, or4.2.2 Through agreement between the party requesting thetest and the testing laboratory.4.3 Puncture of the test specimen i
11、s assessed by visualexamination and, if necessary, verified by conducting a water-tightness test.5. Significance and Use5.1 An important factor affecting the performance of manymembrane roofing systems is their ability to resist staticpuncture loads. This test method provides a means for assess-ing
12、static puncture resistance.5.2 This test method can be used to compare the punctureresistance of a single type of membrane as a function of avariety of insulation substrates or, conversely, to compare theresistance of a number of membrane specimens set on a singletype of insulation.1This test method
13、 is under the jurisdiction of ASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.20 onRoofing Membrane Systems.Current edition approved July 1, 2018. Published July 2018. Originally approvedin 1994. Last previous edition approved in 2011 as D5602/D560
14、2M 11. DOI:10.1520/D5602_D5602M-18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM Internation
15、al, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides
16、 and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15.3 The effect of temperature on puncture resistance can bestudied by conducting the test under controlled conditionsusing such equipment as an environmental chamber, oven, orfreezer.5.4 This tes
17、t method can be useful for developing perfor-mance criteria for membrane roofing systems.5.5 This test method can be useful for developing classifi-cations of the static puncture resistance of membrane roofingsystems.5.6 While it is considered that the results obtained by thislaboratory test can aff
18、ord a measure of the static punctureresistance of membrane roofing systems in the field providedthat service loads and temperature conditions are known, nodirect correlation has yet been established.5.7 This test method can be useful for evaluating the staticpuncture resistance of membranes used in
19、vegetative roofsystems.6. Apparatus6.1 Static Puncture DeviceAn apparatus consisting pri-marily of a movable rod to which a 10-mm 0.39-in. diameterball bearing is attached at one end and a means for loading thespecimen is attached to the other (Fig. 1). The rod shall besufficiently rigid so that it
20、will not flex or rotate when usedunder the maximum test load.NOTE 1One means for loading the specimen is to attach a platform,on which deadweights are placed, to the rod. Another method is to usepneumatic loading whereby the ball bearing is attached to the piston rodand the load is measured by an ai
21、r pressure gage that has been calibratedagainst a load cell.6.1.1 The length of the rod above the specimen shall besufficient to provide adequate space for placing the specimenproperly on the insulation substrate. A framework, having aminimum width of 250 mm 9.8 in., supports the rod perpen-dicular
22、to the surface of the test specimen. Free verticalmovement of the rod shall not be hindered by the framework.The rod and framework shall be capable of supporting punctureloads up to at least 250 N 56 lbf.7. Sampling and Sample Preparation7.1 Single-Ply SamplesCut the test specimens directlyfrom the
23、sheet membrane material using the directions pro-vided in 8.1.7.2 Multi-Ply Samples Prepared in the Laboratory:7.2.1 Condition all components at 23 6 2C 74 6 3F and50 6 5 % relative humidity for 24 6 0.25 h prior to construct-ing the membrane sample.7.2.2 Prepare multi-ply membrane samples at least
24、0.90 by1.20 m 3 by 4 ft, in accordance with the membranemanufacturers instructions, or using other preparation meth-ods at the discretion of the test laboratory. The method ofpreparation shall be described in the test report. The quantity ofmaterial in each layer of the membrane sample shall be with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5602D5602M2018STANDARDTESTMETHODFORSTATICPUNCTURERESISTANCEOFROOFINGMEMBRANESPECIMENSPDF

链接地址:http://www.mydoc123.com/p-520214.html