ASTM D5385 D5385M-1993(2014)e1 Standard Test Method for Hydrostatic Pressure Resistance of Waterproofing Membranes《防水薄膜抗流体静压力的标准试验方法》.pdf
《ASTM D5385 D5385M-1993(2014)e1 Standard Test Method for Hydrostatic Pressure Resistance of Waterproofing Membranes《防水薄膜抗流体静压力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5385 D5385M-1993(2014)e1 Standard Test Method for Hydrostatic Pressure Resistance of Waterproofing Membranes《防水薄膜抗流体静压力的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5385/D5385M 93 (Reapproved 2014)1Standard Test Method forHydrostatic Pressure Resistance of WaterproofingMembranes1This standard is issued under the fixed designation D5385/D5385M; the number immediately following the designation indicates theyear of original adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was editorially corrected in May 2014.1. Scope1.1 This test method measures the hyd
3、rostatic resistance ofa waterproofing membrane under controlled laboratory condi-tions. This test method is not suitable for systems that rely onconfinement of the seams by the backfill since backfill is notpart of this test method.1.2 The values stated in either SI units or inch-pound unitsare to b
4、e regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of th
5、esafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 post-formed crackfor the purposes
6、of this testmethod, one that forms and widens behind the waterproofingmembrane after it has been applied and cured.3. Significance and Use3.1 This test method tests the hydrostatic resistance of awaterproofing membrane and can be used to compare thehydrostatic resistance of waterproofing membranes.3
7、.2 No correlation has been established between the perfor-mance in this test method and that in the field.4. Apparatus4.1 Hydrostatic Testing Equipment, including a chamber(Fig. 1), and a clamping bracket (Fig. 2), and the gasket andfasteners to form the completed assembly (Fig. 3).4.2 Conditioning
8、Room, with forced air circulation to main-tain a temperature of 2 to 7C 35 to 45F for testing sheetsystems, 18 to 24C 65 to 75F for liquid-applied systems,and large enough to condition, prepare, and test samples.4.3 Source of Compressed Air, with pressure up to 690 kPa100 psi and with an air pressur
9、e controller to regulate the airin 103-kPa 15-psi increments.4.4 Cut Off Saw, equipped with a diamond or masonryblade, to prepare precast concrete blocks for testing substrates.4.5 ClockEither a common time piece or a 1-h intervaltimer.4.6 Silicone Vacuum Grease.4.7 Precast-Concrete Patio Blocks, 12
10、5-lb/ft3minimumdensity, 2100-psi minimum compressive strength, smoothsurfaced, 191 by 394 by 51 mm 712 by 1512 by 2 in.5. Test Substrate Preparation5.1 Cut an approximately 3.2-mm 18-in. wide kerf 44 mm134 in. deep lengthwise down the center of a 191 by 394 by51-mm 712 by 1512 by 2-in. concrete bloc
11、k.5.2 Cut a kerf in at least three blocks for each system to betested, and condition the blocks at the test temperature for atleast 24 h.5.3 Condition all other materials necessary for the system tobe tested at the test temperature for at least 4 h.6. Sample Preparation6.1 Prime, surface condition,
12、or otherwise prepare the sur-face of the block to receive the membrane, as recommended bythe manufacturer of the system. Permit the primer to dry orcure for the minimum time recommended by the manufacturer.6.2 For single-ply sheet samples, cut and install the mem-brane over the prepared block, with
13、a lap of the width1This test method is under the jurisdiction of ASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.22 onWaterproofing and Dampproofing Systems.Current edition approved May 1, 2014. Published May 2014. Originallyapproved in 1993. Last
14、previous edition approved in 2006 as D5385 93 (2006).DOI: 10.1520/D5385_D5385M-93R14E01.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1recommended by the manufacturer perpendicular to and in thecenter of the kerf in the other side of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD5385D5385M19932014E1STANDARDTESTMETHODFORHYDROSTATICPRESSURERESISTANCEOFWATERPROOFINGMEMBRANES 防水

链接地址:http://www.mydoc123.com/p-519648.html