ASTM D5329-2007 Standard Test Methods for Sealants and Fillers Hot-Applied for Joints and Cracks in Asphaltic and Portland Cement Concrete Pavements《沥青及硅酸盐水泥混凝土路面接缝与裂纹用热铺密封料和填充料的标准.pdf
《ASTM D5329-2007 Standard Test Methods for Sealants and Fillers Hot-Applied for Joints and Cracks in Asphaltic and Portland Cement Concrete Pavements《沥青及硅酸盐水泥混凝土路面接缝与裂纹用热铺密封料和填充料的标准.pdf》由会员分享,可在线阅读,更多相关《ASTM D5329-2007 Standard Test Methods for Sealants and Fillers Hot-Applied for Joints and Cracks in Asphaltic and Portland Cement Concrete Pavements《沥青及硅酸盐水泥混凝土路面接缝与裂纹用热铺密封料和填充料的标准.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5329 07Standard Test Methods forSealants and Fillers, Hot-Applied, for Joints and Cracks inAsphaltic and Portland Cement Concrete Pavements1This standard is issued under the fixed designation D 5329; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover tests for hot-applied types ofjoint and crack se
3、alants and fillers for portland cement concreteand asphaltic concrete pavements. There are numerous stan-dard material specifications that use these test methods. Referto the respective standard material specification of interest todetermine which of the following test methods to use. Forsample melt
4、ing and concrete block preparation see theirrespective standard practices.1.2 The test methods appear in the following sections:SectionArtificial Weathering 15Asphalt Compatibility 14Bond, Non-Immersed 9Bond, Fuel-Immersed 11Bond, Water-Immersed 10Cone Penetration, Non-Immersed 6Cone Penetration, Fu
5、el-Immersed 7Flexibility 18Flow 8Resilience 12Resilience, Oven-Aged 13Solubility 17Tensile Adhesion 161.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are provided forinformation purposes only.1.4 This standard does not purport to address all of th
6、esafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 1442 Practice for Conduct
7、ing Tests on Sealants UsingArtificial Weathering ApparatusD5 Test Method for Penetration of Bituminous MaterialsD 217 Test Methods for Cone Penetration of LubricatingGreaseD 471 Test Method for Rubber PropertyEffect of LiquidsD 1074 Test Method for Compressive Strength of Bitumi-nous MixturesD 1561
8、Practice for Preparation of Bituminous Mixture TestSpecimens by Means of California Kneading CompactorD 1985 Practice for Preparing Concrete Blocks for TestingSealants, for Joints and CracksD 3381 Specification for Viscosity-Graded Asphalt Cementfor Use in Pavement ConstructionD 5167 Practice for Me
9、lting of Hot-Applied Joint andCrack Sealant and Filler for EvaluationD 6690 Specification for Joint and Crack Sealants, HotApplied, for Concrete and Asphalt PavementsE 145 Specification for Gravity-Convection and Forced-Ventilation OvensE 171 Specification for Atmospheres for Conditioning andTesting
10、 Flexible Barrier MaterialsG23 Practice for Operating Light-Exposure Apparatus(Carbon-Arc Type) With and Without Water for Exposureof Nonmetallic Materials (Discontinued 2001)3G 151 Practice for Exposing Nonmetallic Materials in Ac-celerated Test Devices that Use Laboratory Light SourcesG 153 Practi
11、ce for Operating Enclosed Carbon Arc LightApparatus for Exposure of Nonmetallic MaterialsG 154 Practice for Operating Fluorescent Light Apparatusfor UV Exposure of Nonmetallic MaterialsG 155 Practice for Operating Xenon Arc Light Apparatusfor Exposure of Non-Metallic Materials3. Significance and Use
12、3.1 These test methods describe procedures for determiningspecification conformance for hot-applied, field-molded jointand crack sealants and fillers.4. Sample Melting4.1 See Practice D 5167.1These test methods are under the jurisdiction of ASTM Committee D04 onRoad and Paving Materials and are the
13、direct responsibility of SubcommitteeD04.33 on Formed In-Place Sealants for Joints and Cracks in Pavements.Current edition approved Dec. 1, 2007. Published January 2008. Originallyapproved in 1992. Last previous edition approved in 2004 as D 5329 04.2For referenced ASTM standards, visit the ASTM web
14、site, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
15、 United States.5. Standard Conditions5.1 The laboratory atmospheric conditions, hereinafter re-ferred to as standard conditions, shall be in accordance withSpecification E 171 (23 6 2C (73.4 6 3.6F).6. Cone Penetration, Non-Immersed6.1 ScopeThis test method covers determination of conepenetration of
16、 bituminous joint and crack sealers and fillers.6.2 Significance and UseThe cone penetration, non-immersed is a measure of consistency. Higher values indicatea softer consistency.6.3 ApparatusConduct this test using the apparatus de-scribed in Test Method D5, except as specified herein. Use apenetra
17、tion cone in place of the standard penetration needle.The cone shall conform to the requirements given in TestMethods D 217, except that the interior construction may bemodified as desired. The total moving weight of the cone andattachments shall be 150.0 6 0.1 g.6.4 Specimen PreparationPour a porti
18、on of the sampleprepared in accordance with Practice D 5167 into one 177 mL(6 oz) tin measuring approximately 70 mm in diameter and 45mm in depth and fill flush with the rim of the tin. Allow thespecimen to cure under standard conditions as specified in itsrespective material specification.6.5 Proce
19、durePlace the specimen in a water bath main-tained at 25 6 0.1C (77 6 0.2F) for 2 h immediately beforetesting. Remove the specimen from the bath and dry thesurface. Using the apparatus described in 6.3, make determi-nations at three locations on 120 radii, and halfway betweenthe center and outside o
20、f the specimen. Take care to ensure thecone point is placed on a point in the specimen that isrepresentative of the material itself and is free of dust, water,bubbles or other foreign material. Clean and dry the cone pointafter each determination.6.6 ReportAverage the three results and record the va
21、lueas the penetration of the specimen in110 mm units.6.7 Precision and Bias:6.7.1 For Specification D 6690 Type I materials, the follow-ing precision statement is based on an interlaboratory study of12 laboratories that tested five different Specification D 6690Type I materials.6.7.1.1 Within TinSin
22、gle-Operator Precision (for penetra-tion between 40 and 80): The single-operator deviation hasbeen found to be 0.994. Therefore, results of two properlyconducted tests by the same operator should not differ by morethan three penetration units.6.7.1.2 Within and Between LaboratoriesSingle-OperatorPre
23、cision (penetrations 40 to 80): The single-operator standarddeviation of a single test (test result is defined as the average ofthree penetrations) has been found to be 0.924. Therefore, theresults of two properly conducted tests by the same operator onthe same material should not differ by more tha
24、n threepenetration units.6.7.1.3 Multilaboratory Precision(penetration 40 to 80):The multilaboratory standard deviation of a single test (testresult is defined as the average of three penetrations) has beenfound to be 3.249. Therefore, the results of two properlyconducted tests in different laborato
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD53292007STANDARDTESTMETHODSFORSEALANTSANDFILLERSHOTAPPLIEDFORJOINTSANDCRACKSINASPHALTICANDPORTLANDCEMENTCONCRETEPAVEMENTS

链接地址:http://www.mydoc123.com/p-519490.html