ASTM D5227-2013 Standard Test Method for Measurement of Hexane Extractable Content of Polyolefins《测量聚烯烃可提取正乙烷含量的标准试验方法》.pdf
《ASTM D5227-2013 Standard Test Method for Measurement of Hexane Extractable Content of Polyolefins《测量聚烯烃可提取正乙烷含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5227-2013 Standard Test Method for Measurement of Hexane Extractable Content of Polyolefins《测量聚烯烃可提取正乙烷含量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5227 13Standard Test Method forMeasurement of Hexane Extractable Content of Polyolefins1This standard is issued under the fixed designation D5227; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method describes an extraction/gravimetricprocedure for determination of the amount of hexane solublelow molecular we
3、ight material present in polyethylene,polypropylene, ethylene-propylene copolymers, and ethylene-vinyl acetate copolymers. This test method is a modification ofthe Food and Drug Administration (FDA) procedure fordetermining hexane extractables of polyolefins. This testmethod is based upon the presum
4、ption that the weight of theresidue extract present in the solvent is equal to the amountextracted from the film sample and could therefore be quanti-fied by measuring the weight loss of the extracted film,eliminating the complex and time-consuming evaporationprocess described in 21 CFR 177.1520.1.2
5、 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.3 The values sta
6、ted in SI units are to be regarded as thestandard. Units used in 21 CFR 177.1520 are also used in thistest method. Units are in conformance with Federal Code 21CFR 177.1520, from which this test method is derived.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM
7、 Standards:2D883 Terminology Relating to PlasticsD1239 Test Method for Resistance of Plastic Films toExtraction by ChemicalsD1600 Terminology forAbbreviated Terms Relating to Plas-ticsE131 Terminology Relating to Molecular SpectroscopyE691 Practice for Conducting an Interlaboratory Study toDetermine
8、 the Precision of a Test Method2.2 Federal Document:321 CFR 177.15203. Terminology3.1 The definitions given in Terminology D883, D1600, andE131 are applicable to this test method.3.2 Abbreviations:3.2.1 EVAethylene-vinyl acetate copolymer.3.2.2 LDPElow-density polyethylene.3.2.3 HDPEhigh-density pol
9、yethylene.3.2.4 LLDPElinear low-density polyethylene.3.2.5 FDAFood and Drug Administration.3.2.6 PPpolypropylene.4. Summary of Test Method4.1 Film samples are extracted with hexane for 2 h at 49.56 0.5C, dried, and weighed.4.2 The loss in weight of the film is presumed to be equal tothe extractable
10、content determined by solvent evaporation inthe FDA protocol.5. Significance and Use5.1 FDA requirements for maximum extractables are speci-fied for resin and uses. This test method provides a means todetermine the amount of hexane-soluble low molecular weightmaterial present in polyolefins. It is a
11、pplicable to resinscontaining greater than 0.20 % extractables.6. Apparatus6.1 Water Bath, maintained at 49.5 6 0.5C.6.2 Resin Kettle, 1500-mL.6.3 Kettle Head, 3-neck, with one 45/50 and two 24/40female joints, and appropriate stoppers.6.4 Clamp.6.5 Allihn Condenser, Size C, with 45/50 male joint.1T
12、his test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current edition approved June 1, 2013. Published July 2013. Originally approvedin 1992. Last previous edition approved in 2008 as D5227 - 01(2008)1
13、. DOI:10.1520/D5227-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Docume
14、nts Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/www.dodssp.daps.mil.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.6 P
15、lastic Sleeves, tetrafluoroethylene (TFE), to fit Allihncondenser 45/50 male joint.6.7 Vacuum Oven, capable of maintaining 80 6 5C and aminimum of 25-in. Hg pressure.6.8 Magnetic Stirring Bar, egg-shaped, TFE-coated, 112 by58 in.6.9 Submersible Magnetic Stirring Motor, with power sup-ply.6.10 Analyt
16、ical Balance, capable of weighing to 0.1 mg.7. Reagents and Materials7.1 n-Hexane, aromatic free (1 mg/L), minimum 85 %n-Hexane-reagent grade or equivalent. The solvent must befree of aromatic compounds that would significantly increasethe solubility of the resin. The solvent grade specified repre-s
17、ents the minimum required purity.8. Materials8.1 Blown Film, compression molded films, or cast films aresuitable for testing.8.2 Film, approximately 2.5 g, with a thickness not exceed-ing 4 mil is required for a single determination.9. Procedure9.1 Assemble the resin kettle setup with glass stopper,
18、clamp, and magnetic stirring bar. (See Fig. 1.)9.2 Add 1000 mL of n-Hexane to the kettle assembly.9.3 Stopper the kettle and clamp the assembly into the waterbath set at 49.5 6 0.5C.NOTE 2Temperature is a critical factor in this analysis and must notvary more than 1C. If the temperature exceeds thes
19、e limits, the test mustbe discontinued and restarted. The FDA protocol also states the tempera-ture of the contents must be brought to 49.5 6 0.5C within 20 to 25 min.NOTE 3The level of water in the bath must be kept at least 2 cm abovethe level of the solvent in the kettle to ensure the temperature
20、 equilibrium.Position the kettle so that the center bottle of the kettle is sitting on asubmersible stirrer. Start stirring and allow the hexane to heat for 1 h.9.4 Using gloves and metal tweezers to avoid samplecontamination, cut 2.7 g of the prepared film sample (4 mil orless in thickness) into 1-
21、in. squares using clean sharp scissors.NOTE 4Care must be exercised when cutting the samples to avoidragged edges on the specimen. Small shards of film or contaminationpresent at initial weighing can easily be lost during the test, adverselyaffecting the test results.9.5 Weigh 2.5 6 0.05 g of film s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD52272013STANDARDTESTMETHODFORMEASUREMENTOFHEXANEEXTRACTABLECONTENTOFPOLYOLEFINS 测量 烯烃 提取 乙烷 含量 标准

链接地址:http://www.mydoc123.com/p-519204.html