ASTM D5224-2012 Standard Practice for Compression Molding Test Specimens of Thermosetting Molding Compounds《热固模塑料的压缩模制试样的标准实施规程》.pdf
《ASTM D5224-2012 Standard Practice for Compression Molding Test Specimens of Thermosetting Molding Compounds《热固模塑料的压缩模制试样的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5224-2012 Standard Practice for Compression Molding Test Specimens of Thermosetting Molding Compounds《热固模塑料的压缩模制试样的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5224 12Standard Practice forCompression Molding Test Specimens of ThermosettingMolding Compounds1This standard is issued under the fixed designation D5224; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice covers the general principles to be fol-lowed when compression molding test specimens of thermo-setting
3、molding compounds, such as phenolics, aminoplastics,melamine phenolics, epoxies, and unsaturated polyesters.1.2 Molding conditions are given for amino, phenolic, andallyl molding compounds. The exact molding conditions willvary from material to material, and, if not incorporated in thematerial speci
4、fication, shall be agreed upon between thepurchaser and the supplier or determined by previous experi-ence with the particular type of material being used1.3 The values stated in SI units are to be regarded asstandard. The values in parentheses are given for informationonly.1.4 This standard does no
5、t purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This standard and ISO 295 address
6、the same subject matter,but differ in technical content.2. Referenced Documents2.1 ASTM Standards:2D638 Test Method for Tensile Properties of PlasticsD883 Terminology Relating to Plastics2.2 ISO Standard:ISO 295 PlasticsCompression Molding Test Specimensof Thermosetting Materials3ISO 3167 PlasticsMu
7、ltipurposeTest Specimens33. Terminology3.1 DefinitionsFor definitions of terms pertaining to plas-tics used in this practice, see Terminology D883.3.2 Definitions of Terms Specific to This Standard:3.2.1 breathe step, nin plastics molding, the part of themolding cycle in which the mold halves are op
8、ened momen-tarily, prior to curing, to release volatiles from the molded part.3.2.2 skin, nin plastics molding, the thin resin-rich layer(skin) on the surface of the molded part.3.2.3 skin effect, nin plastics testing, the positive ornegative effect on the results of some standard tests attributable
9、to the skin.4. Summary of Practice4.1 Compression molded test specimens are produced byloading a mold cavity with some form of the molding material,applying a specified pressure to the mating surface for aspecified time and at a specified temperature, and then remov-ing the part from the cavity.5. S
10、ignificance and Use5.1 The conditions at which compounds are molded areknown to influence the properties of the specimens. The degreeof cure, elimination of knit-lines between particles, density ofthe part, and degradation of the polymer are among thosefactors which will be affected by the molding c
11、onditions. Thusit is important to conform to a standard set of conditions inorder to have a valid comparison of properties betweendifferent compounds and different batches of the same com-pound.5.2 Molded specimens showing evidence of low-densityareas due to trapped gases shall be discarded. A breat
12、he stepcan be incorporated to eliminate this situation. If used, it iscritical that the breathe step be as brief as possible to avoidprecuring of the compound before full pressure is appliedleading to poorly “knitted” areas and lower strength in themolded specimen.6. Apparatus6.1 Molds:1This practic
13、e is under the jurisdiction ofASTM Committee D20 on Plastics andis the direct responsibility of Subcommittee D20.09 on Specimen Preparation.Current edition approved April 1, 2012. Published May 2012. Originallyapproved in 1992. Last previous edition approved in 2006 as D5224 - 00 (2006).DOI: 10.1520
14、/D5224-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3ISO Standards Handbook 21, Vol 2, Plastics, 2nd Ed
15、., 1990, available fromAmerican National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York,NY 10036.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.1.1
16、 The mold shall be made of steel, able to withstand themolding temperatures and pressures. The mold shall be de-signed such that the compressive mold force is transferred tothe molding material with no appreciable loss. The moldsshown in Figs. 1 and 2 are recommended for maintaining themaximum force
17、 on the material. They are of the three-platedesign; consisting of a shell or floating plate, with upper andlower compression plates. Molds may be of single or multiplecavity design.NOTE 2Semi-positive molds can be used, and for materials such asamino compounds, are preferred.6.1.2 The majority of t
18、ests will use bars 12.7 mm (0.5 in.) inwidth by 127 mm (5 in.) or 64 mm (2.5 in.) in length, discs 51mm (2 in.) or 102 mm (4 in.) in diameter or an appropriatetensile bar as described in Test Method D638 or the multi-purpose design from ISO 3167. The mold shall be capable ofmolding thickness from 1.
19、5 mm (0.06 in.) to 12.5 mm (0.5 in.).Some procedures such as flame testing require thinner speci-mens. In all cases the ASTM Standard Test Procedure to beused shall be consulted for the dimensions of the required testspecimens.6.1.3 If at all possible, specimens shall be molded directly todimension,
20、 rather than machined from a plaque to maintain theintegrity of any skin effect.6.1.3.1 If it is necessary for specimens to be machined fromplates or plaques, they shall not be taken from the edge of theplaque and a minimum margin of 10 mm (0.5 in.) is recom-mended. This shall be noted in the report
21、.6.1.4 A cavity draft angle not exceeding 3 can be used tofacilitate specimen removal.6.1.5 The clearance between the vertical wall of the cavityand that of the force shall not exceed 0.1 mm (0.004 in.).6.1.6 Mold surfaces finished to a roughness of 0.4 to 0.8 m(SPI-SPE #2 or equivalent4) are prefer
22、red, unless it is knownthat the particular test is not affected by a coarser surface finish.Chrome plating is recommended but not necessary. Drawpolishing of all cavity surfaces in the direction parallel to theforce will facilitate specimen removal.6.1.7 If ejector pins are used, they shall not defo
23、rm thespecimens and their placement shall be such that the pin marksare not in the area of test.6.1.8 The mold shall have a loading chamber of sufficientvolume to allow the introduction of the entire charge ofmaterial in a single loading. Preforms can be used to decreasethe required loading volume o
24、f high bulk materials. Theconditions of such preforming shall be included in the report.6.1.9 As the specimen surface facing the lower die is heatedfor a longer time and at a higher temperature in the timeinterval between filling and compression, it is recommendedthat a mark be placed on one cavity
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD52242012STANDARDPRACTICEFORCOMPRESSIONMOLDINGTESTSPECIMENSOFTHERMOSETTINGMOLDINGCOMPOUNDS 热固模 塑料

链接地址:http://www.mydoc123.com/p-519194.html