《ASTM D4671-2016 Standard Test Method for Polyurethane Raw Materials Determination of Unsaturation of Polyols《聚亚胺酯原材料的标准试验方法 多元醇不饱和度的测定》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4671-2016 Standard Test Method for Polyurethane Raw Materials Determination of Unsaturation of Polyols《聚亚胺酯原材料的标准试验方法 多元醇不饱和度的测定》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4671 05(Reapproved 2010)1D4671 16Standard Test MethodsMethod forPolyurethane Raw Materials: Determination of Unsaturationof Polyols1This standard is issued under the fixed designation D4671; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEReapproved with editorial changes in July 2010.1. Scope Scope*1.1 TheseThis test methods m
3、easuremethod measures unsaturation in polyether polyols. (See Note 1.) It uses 2 mL of ca. 0.05M mercuric acetate reagent in methanol and about 1 g of sample or less. This test method uses a potentiometric determination ofan end point.1.1.1 Test Method A, High-Volume Reagent MethodUses about 50 mL o
4、f 0.1 M mercuric acetate reagent in methanol and 15g or more of sample. These test methods use an indicator for colorimetric determination of an end point. It is recommended forpolyols with low values (below 0.01 millequivalents per gram (meq/g) of unsaturation where large sample sizes are required.
5、1.1.2 Test Method B, Low-Volume Reagent MethodUses 2 mL of ca. 0.05 M mercuric acetate reagent in methanol and about1 g of sample or less. These test methods use a potentiometric determination of an end point.1.2 The values stated in SI units are to be regarded as standard. No other units of measure
6、ment are included in this standard.1.3 Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues.Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Caution should be taken whenhandling mercur
7、y and mercury containing products. See the applicable product Safety Data Sheet (SDS) for additionalinformation. Users should be aware that selling mercury and/or mercury containing products into your state or country may beprohibited by law.1.4 This standard does not purport to address all of the s
8、afety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 1There is no known ISO equivalent to this standard.This standard is eq
9、uivalent to ISO 17710.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsE180 Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals(Withdrawn 2009)32.2 ISO Standards:ISO 17710 PlasticsPolyols for Use in the
10、Production of PolyurethaneDetermination of Degree of Unsaturation byMicrotitration43. Terminology3.1 DefinitionsFor definitions of terms used in these test methods, see Terminology D883.1 These test methods are under the jurisdiction of ASTM Committee D20 on Plastics and are the direct responsibilit
11、y of Subcommittee D20.22 on Cellular Materials -Plastics and Elastomers. Test Method A was recommended to ASTM by the Society of the Plastics Industry Polyurethane Raw Materials Analysis Committee.Current edition approved July 1, 2010April 1, 2016. Published October 2010April 2016. Originally approv
12、ed in 1987. Last previous edition approved in 20052010 asD4671 - 05.D4671 - 05 (2010)1. DOI: 10.1520/D4671-05R10E01.10.1520/D4671-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume inform
13、ation, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.4 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document
14、 is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appr
15、opriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United Sta
16、tes14. Summary of Test Method4.1 Carbon-to-carbon unsaturated compounds in the sample are reacted with mercuric acetate and methanol in a methanolicsolution to produce acetoxymercuricmethoxy compounds and acetic acid.5 The amount of acetic acid released in this equimolarreaction, which is determined
17、 by titration with standard alcoholic potassium hydroxide, is a measure of the unsaturation originallypresent. Because the acid cannot be titrated in the presence of excess mercuric acetate, due to the formation of insoluble mercuricoxide, sodium bromide is added to convert the mercuric acetate to t
18、he bromide, which does not interfere. Inasmuch as these testmethods are based on an acidimetric titration, a suitable correction must be applied if the sample is not neutral to phenolphthaleinindicator. Take care to exclude carbon dioxide, which titrates as an acid and gives erroneous results.5. Sig
19、nificance and Use5.1 TheseThis test methods aremethod is suitable for quality control, as specification tests, and for research.5.2 Side reactions that form unsaturated compounds in polypropylene oxides produce small amounts of polymers with only onehydroxyl group per chain. These unsaturated polyme
20、rs lower functionality and molecular weight, while broadening the overallmolecular-weight distribution.6. Interferences6.1 TheseThis test methods domethod does not apply to compounds in which the unsaturation is conjugated with carbonyl,carboxyl, or nitrile groups. Because water presumably hydrolyze
21、s the reaction products to form basic mercuric salts, quantitativeresults are obtained only when the system is essentially anhydrous. Acetone in low concentrations does not interfere significantly,although its presence can be detrimental to the end point. Inorganic salts, especially halides, must be
22、 absent from the samplebecause even small amounts of salts can nullify the reaction of the mercuric acetate with the unsaturated compound.TEST METHOD AHIGH-VOLUME REAGENT METHOD7. Apparatus7.1 Pipet, 50-mL capacity.7.2 Erlenmeyer Flask, 250-mL glass-stoppered.7.3 Balance, 1000-g capacity, 0.1-g sens
23、itivity.7.4 Buret, 50-mL capacity.8. Reagents8.1 Purity of ReagentsUse reagent-grade chemicals in all tests. Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the Committee on Analytical Reagents of the American Chemical Society, where suchspecificati
24、ons are available.5 Other grades are acceptable, provided it is first ascertained that the reagent is of sufficiently highpurity to permit its use without lessening the accuracy of the determination.8.2 Mercuric Acetate, Methanol Solution (40 g/L)Dissolve 40 g of mercuric acetate (Hg(C2H3O2)2 in suf
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD46712016STANDARDTESTMETHODFORPOLYURETHANERAWMATERIALSDETERMINATIONOFUNSATURATIONOFPOLYOLS 亚胺 原材料

链接地址:http://www.mydoc123.com/p-517657.html