1、Designation: D 4658 08Standard Test Method forSulfide Ion in Water1This standard is issued under the fixed designation D 4658; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indic
2、ates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method uses an ion-selective electrode todetermine sulfide ion in water. The test method is applicable inthe range from 0.04 to 4000 mg/L of sulfide.1.2
3、 Precision data presented in this test method were ob-tained using reagent water only. It is the users responsibility toensure the validity of this test method for untested types ofwater.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in th
4、isstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Sul
5、fide samples,when acidified, can release highly toxic hydrogen sulfide gas.For a specific precautionary statement, see Note 2.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 1193 Specification for Reagent WaterD 2777 Practice for Determination of Precision and Bias o
6、fApplicable Test Methods of Committee D19 on WaterD 3370 Practices for Sampling Water from Closed ConduitsD 4127 Terminology Used with Ion-Selective ElectrodesD 5810 Guide for Spiking into Aqueous SamplesD 5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water An
7、alysis3. Terminology3.1 Definitions: For definitions of terms used in this testmethod, refer to Terminology D 1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 For definitions of terms specific to this test method,refer to Terminology D 4127.4. Summary of Test Method4.1 Sulfide ion is me
8、asured potentiometrically using asulfide ion-selective electrode in conjunction with a double-junction sleeve type reference electrode. Potentials are readusing a pH meter having an expanded millivolt scale capable ofbeing read to the nearest 0.1 mV, or a specific ion meter havinga direct concentrat
9、ion scale for sulfide ion.4.2 Samples are treated prior to analysis with sulfide anti-oxidant buffer (SAOB). This buffer fixes the solution pH at ahighly alkaline level and contains ascorbic acid to retard airoxidation of sulfide ion in solution.This ensures that the sulfidepresent occurs chiefly as
10、 S2ion rather than as complexedHS1or H2S that are present at lower pH values.5. Significance and Use5.1 Sulfide ion is found in ground waters and wastewater,causing odor and corrosion problems. If acidified, these waterscan release hydrogen sulfide, which is extremely toxic even atlow levels. This t
11、est method provides a means for interference-free measurement of free sulfide ion.NOTE 1Sulfide forms complexes with hydrogen ions (HS1and H2S).In addition, sulfide ion forms soluble complexes with elemental sulfur(S22,S32,S42, etc.), tin, antimony, and arsenic ions.6. Apparatus6.1 pH Meter, with ex
12、panded millivolt scale, or a specificion meter having a direct concentration scale for sulfide ion.6.2 Sulfide Ion-Selective Electrode.1This test method is under the jurisdiction of ASTM Committee D19 on Waterand are the direct responsibility of Subcommittee D19.05 on Inorganic Constituentsin Water.
13、Current edition approved Aug. 15, 2008. Published August 2008. Originallyapproved in 1987. Last previous edition approved in 2003 as D 4658 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vo
14、lume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.3 Reference Electrode, double-junction sleeve type with1.0 M potassium nitrate solution, pH adjusted
15、to 13.5 with 1.0M sodium hydroxide in the outer sleeve.7. Reagents7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee onAnalytical Reagents of theAmerican Chemical S
16、ociety.3Other grades may be used, provided it is first ascertained thatthe reagent is of sufficiently high purity to permit its usewithout lessening the accuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referenceto water shall be understood to mean reagent water conforming
17、to Specification D 1193, Type I. Other reagent water types maybe used provided it is first ascertained that the water is ofsufficiently high purity to permit its use without adverselyaffecting the bias and precision of the test method. Type IIIwater was specified at the time of round robin testing o
18、f thismethod.7.3 Cadmium Nitrate Solution (0.1 M)Place 12.84 g ofcadmium oxide into a 125-mL beaker. Add 12 to 14 mL ofconcentrated nitric acid (sp gr 1.42), stir with a glass stirringrod, and add about 10 mL of water. Stir thoroughly, add anadditional 40 to 50 mL of water, washing off the glass sti
19、rringrod with part of the water. Transfer to a 1-L volumetric flaskand dilute to 1000 mL with water.7.4 Lead Perchlorate Solution (0.1 M)Commerciallyavailable. Alternatively, it can be prepared using lead perchlo-rate and water. Dissolve 46.02 g of the salt in water using a 1-Lvolumetric flask and d
20、ilute to 1000 mL with water.7.5 Sodium Sulfide Solution, StockPrepare sodium sulfidestock solution from sodium sulfide hydrate (Na29H2O).NOTE 2Warning: All sulfide solution preparation and measurementmust be performed in a hood to avoid breathing noxious fumes.7.5.1 Precise standards cannot be prepa
21、red by weighing thesalt because of the large and variable water of hydration.Instead, prepare a saturated sodium sulfide solution by addingapproximately 100 g of the Na2S9H2O to approximately 100mLof water, shake well, stopper securely, and allow it to stand,at least overnight.7.5.2 To prepare the s
22、odium sulfide stock solution, pipette 1mL of the saturated solution described above into 50 mL ofSAOB (7.6), and dilute to 100 mL with water.7.6 Sulfide Anti-Oxidant Buffer (SAOB)In a 1000-mLbeaker containing approximately 600 mLof water, add 200 mLof 10 M sodium hydroxide (or 80 g pellets), 35 g of
23、 ascorbicacid, and 67 g of disodium EDTA. Stir until everythingdissolves and transfer the solution to a 1000-mL volumetricflask. Dilute to the mark with water. The solution compositionis as follows; 2 M NaOH; 0.2 M ascorbic acid, and 0.2 Mdisodium EDTA (dihydrate).NOTE 3Freshly prepared SAOB, when s
24、tored in a tightly stopperedbottle, has a shelf life of approximately two weeks, if opened frequently.When oxidized, the solution turns dark brown and should be discarded.7.7 Zinc Acetate Solution (2.0 M)Dissolve 43.90 g ofzinc acetate Zn(C2H3O2)22H2O in water, using a 100 mLvolumetric flask, and di
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD46582008STANDARDTESTMETHODFORSULFIDEIONINWATERPDF

链接地址:http://www.mydoc123.com/p-517627.html