ASTM D3235-2016 Standard Test Method for Solvent Extractables in Petroleum Waxes《石油蜡中溶剂可萃取物的标准试验方法》.pdf
《ASTM D3235-2016 Standard Test Method for Solvent Extractables in Petroleum Waxes《石油蜡中溶剂可萃取物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3235-2016 Standard Test Method for Solvent Extractables in Petroleum Waxes《石油蜡中溶剂可萃取物的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3235 16Standard Test Method forSolvent Extractables in Petroleum Waxes1This standard is issued under the fixed designation D3235; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of solventextractables in petroleum waxes.1.2 The values stated in SI units are to be regarded asstand
3、ard.1.2.1 ExceptionThe values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determin
4、e the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1 Specification for ASTM Liquid-in-Glass ThermometersE128 Test Method for Maximum Pore Diameter and Perme-ability of Rigid Porous Filters for Laboratory Use3. Summary of Test Method3.1 The sample
5、is dissolved in a mixture consisting of 50 %by volume methyl ethyl ketone and 50 % by volume toluene.The solution is cooled to 32 C (25 F) to precipitate thewax, then filtered. The solvent extractables content is deter-mined by evaporating the solvent from the filtrate and deter-mining the mass of t
6、he residue.4. Significance and Use4.1 The solvent extractables in a wax may have significanteffects on several of its properties such as strength, hardness,flexibility, scuff resistance, coefficient of friction, coefficient ofexpansion, melting point, and staining characteristics. Whetherthese effec
7、ts are desirable or undesirable depends on theintended use of the wax.5. Apparatus5.1 Filter Stick and Assembly, consisting of a 10 mm diam-eter sintered glass filter stick of 10 m to 15 m maximum porediameter as determined by the method in Appendix X1,provided with an air pressure inlet tube and de
8、livery nozzle. Itis provided with a ground-glass joint to fit a 25 mm by 170 mmtest tube. The dimensions for a suitable filtration assembly areshown in Fig. 1.NOTE 1A metallic filter stick may be employed if desired. A filterstick3made of stainless steel and having a 12.7 mm (0.50 in.) disk of10 nm
9、to 15 nm maximum pore diameter, as determined by Test MethodE128, has been found to be satisfactory. The metallic apparatus is insertedinto a 25 mm by 150 mm test tube and held in place by means of a cork.5.2 Cooling Bath, consisting of an insulated box with30 mm 6 5 mm (1.2 in. 6 0.2 in.) holes in
10、the center toaccommodate any desired number of test tubes. The bath maybe filled with a suitable medium such as kerosine, and may becooled by circulating a refrigerant through coils, or by usingsolid carbon dioxide. A suitable cooling bath to accommodatethree test tubes is shown in Fig. 2.5.3 Droppe
11、r Pipet, dispensing device capable of delivering0.5 g 6 0.05 g of molten wax.5.4 Transfer Pipet, or equivalent volume dispensing device,capable of delivering 15 mL 6 0.06 mL.5.5 Air Pressure Regulator, designed to supply air to thefiltration assembly (8.5) at sufficient pressure to give an evenflow
12、of filtrate. Either a conventional pressure-reducing valveor a mercury bubbler-type regulator has been found satisfac-tory. The latter type, illustrated in Fig. 3, consists of a 250 mLglass cylinder and a T-tube held in the cylinder by means of arubber stopper grooved at the sides to permit the esca
13、pe ofexcess air. The volume and pressure of the air supplied to thefiltration assembly is regulated by the depth to which theT-tube1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.
14、10.0A on Physical/Chemical Properties.Current edition approved July 1, 2016. Published July 2016. Originally approvedin 1973. Last previous edition approved in 2015 as D3235 15. DOI: 10.1520/D3235-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servic
15、e at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of supply of a suitable metal filter stick with designatedporosity G known to the committee at this time is the Pall Trinity Micro Corp.,Route 2
16、81, Cortland, NY13045.Alist of United Kingdom suppliers can be obtainedfrom Energy Institute, 61 New Cavendish St., London, W1G 7AR, United King-dom. If you are aware of alternative suppliers, please provide this information toASTM International Headquarters. Your comments will receive careful consi
17、der-ation at a meeting of the responsible technical committee,1which you may attend.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1is immersed in mercury at the bottom
18、of the cylinder. Absor-bent cotton placed in the space above the mercury prevents theloss of mercury by spattering. The air pressure regulator isconnected to the filter stick and assembly by means of rubbertubing.5.6 Temperature Measuring Devices:5.6.1 Thermometers, two, having a range as shown belo
19、wand conforming to the requirements as prescribed in Specifi-cation E1 or in the specifications for IP Standard Thermom-eters. One thermometer is required for the cold bath and asecond thermometer is required for the sample solution.Thermometer NumberTemperature Range ASTM IP37 C to +21 C 71C 72C35
20、F to +70 F 71F 72F5.6.2 Temperature measuring devices other than those de-scribed in 5.6.1 are satisfactory for this test method, providedthey exhibit the same temperature response as the equivalentmercury-in-glass thermometers.5.7 Weighing Bottles, glass-stoppered, having a typical ca-pacity of 15
21、mL to 25 mL.5.8 Evaporation Assembly, consisting of an evaporatingcabinet and connections, essentially as illustrated in Fig. 4, andcapable of maintaining a temperature of 35 C 6 1 C (95 F6 2 F) around the evaporation flasks. Construct the jets withan inside diameter of 4 mm 6 0.2 mm for delivering
22、a streamof clean, dry air vertically downward into the weighing bottle.Support each jet so that the tip is 15 mm 6 5 mm above thesurface of the liquid at the start of the evaporation. Supplypurified air at the rate of 2 Lmin to 3 Lmin per jet. One wayto purify the air is to pass it through a tube of
23、 approximately1 cm bore packed loosely to a height of approximately 20 cmwith absorbent cotton. Periodically check the cleanliness of theair by evaporating 4 mLof the solvent mixture described in 6.3by the procedure specified in 8.5. When the residue does notexceed 0.1 mg, the evaporation equipment
24、is operating satis-factorily.NOTE 2Investigations by the European World Federation have indi-cated that improved precision may be achieved by individually calibratingeach nozzle to deliver a flow rate of 2 L min to 3 L min.5.9 Analytical Balance, capable of reproducing masses to0.1 mg.5.10 Wire Stir
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD32352016STANDARDTESTMETHODFORSOLVENTEXTRACTABLESINPETROLEUMWAXES 石油 溶剂 萃取 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-514360.html