ASTM D2862-2016 Standard Test Method for Particle Size Distribution of Granular Activated Carbon《颗粒活性炭粒度分布的标准试验方法》.pdf
《ASTM D2862-2016 Standard Test Method for Particle Size Distribution of Granular Activated Carbon《颗粒活性炭粒度分布的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2862-2016 Standard Test Method for Particle Size Distribution of Granular Activated Carbon《颗粒活性炭粒度分布的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2862 10D2862 16Standard Test Method forParticle Size Distribution of Granular Activated Carbon1This standard is issued under the fixed designation D2862; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test method covers the determi
3、nation of the particle size distribution of granular activated carbon. For the purposes ofthis test, granular activated carbon is defined as a minimum of 90 % of the sample weight being retained on a 180-m Standardsieve. A U.S. mesh 80 sieve is equivalent to a 180m Standard sieve.NOTE 1For extruded
4、carbons, as the length/diameter ratio of the particles increases, the validity of the test results might be affected.1.2 The data obtained may also be used to calculate mean particle diameter (MPD), effective size, and uniformity coefficient.1.3 The values stated in inch-pound units are to be regard
5、ed as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3.1 ExceptionAll mass measurements are in SI units only.1.4 This standard does not purport to address all of the safety concerns, if any, a
6、ssociated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2652 Terminology Relating to Activated CarbonD2854 Test
7、Method for Apparent Density of Activated CarbonE11 Specification for Woven Wire Test Sieve Cloth and Test SievesE177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE300 Practice for Sampling Industrial ChemicalsE691 Practice for Conducting an Interlaboratory Study to Determine
8、the Precision of a Test Method3. Summary of Test Method3.1 A known weight of granular activated carbon is placed on the top sieve of a stacked set of U.S. Standard sieves and shakenunder standard conditions for a specific time period, after which the weight percent of the total retained on each siev
9、e and bottompan is determined.4. Significance and Use4.1 It is necessary to know the distribution of particle sizes of granular activated carbon in order to provide proper contact ofgases or liquid in a packed bed of the material. Changes in particle size distribution can affect the pressure drop ac
10、ross the bedand the rate of adsorption in a bed of a given size.4.2 Mean particle diameter is a property of activated carbons that influences pressure drop.4.3 Effective size and uniformity coefficient are two properties of activated carbons often of interest in municipal watertreatment applications
11、 where control of particle size is of interest.1 This test method is under the jurisdiction of ASTM Committee D28 on Activated Carbon and is the direct responsibility of Subcommittee D28.04 on Gas PhaseEvaluation Tests.Current edition approved April 1, 2010June 1, 2016. Published July 2010July 2016.
12、 Originally approved in 1970. Last previous edition approved in 20092010 asD2862 97D2862 10. (2009)1. DOI: 10.1520/D2862-10.10.1520/D2862-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolum
13、e information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequa
14、tely depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
15、n, PA 19428-2959. United States15. Apparatus5.1 Mechanical Sieve Shaker3This is a mechanically operated sieve shaker that imparts a uniform rotating and tapping motionto a stack of 8-in. (203-mm or equivalent) sieves as described in 5.2. The sieve shaker should be adjusted to accommodate thedesired
16、number of sieves, receiver pan, and sieve cover. The bottom stops should be adjusted to give a clearance of approximately116 in. (1.5 mm) between the upper carrying plate stops and the sieve cover plate, so that the sieves will be free to rotate. The sieveshaker shall be powered with 14-hp (186-W) e
17、lectric motor producing 1725 to 1750 rpm. The sieve shaker should produce 140to 160 raps per minute with the striker arm and 280 to 320 rotating motions per minute of the sieve stack. The cover plate shallbe fitted with a cork stopper that shall extend 14 6 18 in. (6.35 6 3.18 mm) above the metal re
18、cess. At no time shall any materialother than cork be permitted.5.2 SievesU.S. Standard sieves or equivalent conforming to Specification E11. The sieves shall be either 2 in. (51 mm) (fullheight) or 1 in. (25 mm.) (half height) in height, and 8 in. (203 mm or equivalent) in diameter.5.3 Bottom Recei
19、ver Pan and Top Sieve Cover.5.4 Interval Timer, adjustable, with an accuracy of 610 s.5.5 Sample Splitter, single-stage riffle type.5.6 Balance, with a sensitivity of 0.1 g.5.7 Soft Brass Wire Brush. 45.8 Cylinder, glass, graduated, 250-mL capacity.5.9 Equivalent ApparatusNewer technology may produc
20、e devices that can perform an equivalent function to the mechanicalsieve shaker described in 5.1, for which this method was originally developed (Tyler model RX-191 or 2). In the case of newerdevices being used, the tester should validate the equivalency of the newer device to that of the ASTM stand
21、ard tester (or itssuccessors, for example,Tyler model RX-29) and retain the capability to cross check the results of particle size distribution analysisbetween the mechanical device described above and any newer sieving system.6. Sampling6.1 Collect and prepare the granular activated carbon samples
22、in accordance with Practice E300.3 The Tyler Ro-Tap Model RX-19-1 has been used in developing this test. Newer models may not produce the same separations (Model RX-19-2 is equivalent to ModelRX-19-1). This model is available from Fisher Scientific, Pittsburgh, PA 15238.4 W. S. Tyler Model 1778-S.B.
23、 or equivalent has been found satisfactory.FIG. 1 Cumulative Particle Size Distribution CurveD2862 1627. Procedure7.1 Stack the sieves to be used on the bottom receiver pan in order of increasing sieve opening from bottom to top.7.2 Prepare a sample of activated carbon as follows:7.2.1 Mix the gross
24、 sample, obtained by Practice E300, by passing it through a single-stage riffle type sample splitter andrecombining twice. Then pass the mixed sample through the riffle so as to obtain an approximate 250-mL of sample.7.2.2 Using the apparent density apparatus described in Test Method D2854, obtain a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD28622016STANDARDTESTMETHODFORPARTICLESIZEDISTRIBUTIONOFGRANULARACTIVATEDCARBON 颗粒 活性炭 粒度 分布 标准 试验

链接地址:http://www.mydoc123.com/p-513664.html