ASTM D2862-2010 Standard Test Method for Particle Size Distribution of Granular Activated Carbon《颗粒活性炭粒度分布的标准试验方法》.pdf
《ASTM D2862-2010 Standard Test Method for Particle Size Distribution of Granular Activated Carbon《颗粒活性炭粒度分布的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2862-2010 Standard Test Method for Particle Size Distribution of Granular Activated Carbon《颗粒活性炭粒度分布的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2862 10Standard Test Method forParticle Size Distribution of Granular Activated Carbon1This standard is issued under the fixed designation D2862; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the determination of the
3、 particlesize distribution of granular activated carbon. For the purposesof this test, granular activated carbon is defined as a minimumof 90 % of the sample weight being retained on a 180-mStandard sieve.AU.S. mesh 80 sieve is equivalent to a 180mStandard sieve.NOTE 1For extruded carbons, as the le
4、ngth/diameter ratio of theparticles increases, the validity of the test results might be affected.1.2 The data obtained may also be used to calculate meanparticle diameter (MPD), effective size, and uniformity coef-ficient.1.3 The values stated in inch-pound units are to be regardedas standard. The
5、values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3.1 ExceptionAll mass measurements are in SI unitsonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
6、 It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2652 Terminology Relating to Activated CarbonD2854 Test Method for Apparent
7、Density of ActivatedCarbonE11 Specification for Woven Wire Test Sieve Cloth and TestSievesE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE300 Practice for Sampling Industrial ChemicalsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test
8、Method3. Summary of Test Method3.1 A known weight of granular activated carbon is placedon the top sieve of a stacked set of U.S. Standard sieves andshaken under standard conditions for a specific time period,after which the weight percent of the total retained on eachsieve and bottom pan is determi
9、ned.4. Significance and Use4.1 It is necessary to know the distribution of particle sizesof granular activated carbon in order to provide proper contactof gases or liquid in a packed bed of the material. Changes inparticle size distribution can affect the pressure drop across thebed and the rate of
10、adsorption in a bed of a given size.4.2 Mean particle diameter is a property of activated car-bons that influences pressure drop.4.3 Effective size and uniformity coefficient are two prop-erties of activated carbons often of interest in municipal watertreatment applications where control of particle
11、 size is ofinterest.5. Apparatus5.1 Mechanical Sieve Shaker3This is a mechanicallyoperated sieve shaker that imparts a uniform rotating andtapping motion to a stack of 8-in. (203-mm or equivalent)sieves as described in 5.2. The sieve shaker should be adjustedto accommodate the desired number of siev
12、es, receiver pan,and sieve cover. The bottom stops should be adjusted to give aclearance of approximately116 in. (1.5 mm) between the uppercarrying plate stops and the sieve cover plate, so that the sieveswill be free to rotate. The sieve shaker shall be powered with14-hp (186-W) electric motor prod
13、ucing 1725 to 1750 rpm. Thesieve shaker should produce 140 to 160 raps per minute withthe striker arm and 280 to 320 rotating motions per minute ofthe sieve stack. The cover plate shall be fitted with a cork1This test method is under the jurisdiction of ASTM Committee D28 onActivated Carbon and is t
14、he direct responsibility of Subcommittee D28.04 on GasPhase Evaluation Tests.Current edition approved April 1, 2010. Published July 2010. Originallyapproved in 1970. Last previous edition approved in 2009 as D2862 97 (2009)1.DOI: 10.1520/D2862-10.2For referenced ASTM standards, visit the ASTM websit
15、e, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The Tyler Ro-Tap Model RX-19-1 has been used in developing this test. Newermodels may not produce the same separa
16、tions (Model RX-19-2 is equivalent toModel RX-19-1). This model is available from Fisher Scientific, Pittsburgh, PA15238.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.stopper that shall extend14 618 in. (6.35 6 3.18 mm) abovethe me
17、tal recess. At no time shall any material other than corkbe permitted.5.2 SievesU.S. Standard sieves or equivalent conformingto Specification E11. The sieves shall be either 2 in. (51 mm)(full height) or 1 in. (25 mm.) (half height) in height, and 8 in.(203 mm or equivalent) in diameter.5.3 Bottom R
18、eceiver Pan and Top Sieve Cover.5.4 Interval Timer, adjustable, with an accuracy of 610 s.5.5 Sample Splitter, single-stage riffle type.5.6 Balance, with a sensitivity of 0.1 g.5.7 Soft Brass Wire Brush.45.8 Cylinder, glass, graduated, 250-mL capacity.5.9 Equivalent ApparatusNewer technology may pro
19、ducedevices that can perform an equivalent function to the me-chanical sieve shaker described in 5.1, for which this methodwas originally developed (Tyler model RX-191 or 2). In thecase of newer devices being used, the tester should validate theequivalency of the newer device to that of the ASTM sta
20、ndardtester (or its successors, for example, Tyler model RX-29) andretain the capability to cross check the results of particle sizedistribution analysis between the mechanical device describedabove and any newer sieving system.6. Sampling6.1 Collect and prepare the granular activated carbonsamples
21、in accordance with Practice E300.7. Procedure7.1 Stack the sieves to be used on the bottom receiver pan inorder of increasing sieve opening from bottom to top.7.2 Prepare a sample of activated carbon as follows:7.2.1 Mix the gross sample, obtained by Practice E300,bypassing it through a single-stage
22、 riffle type sample splitter andrecombining twice. Then pass the mixed sample through theriffle so as to obtain an approximate 250-mL of sample.7.2.2 Using the apparent density apparatus described in TestMethod D2854, obtain a test sample of 200 mL from eachsample. If the apparent density is less th
23、an 0.35 g/cc, a 50 gsample will be adequate, greater than 0.35 g/cc, use a samplenot to exceed 100 g. In all cases, volume of the sample shouldnot exceed 200 ml.4W. S. Tyler Model 1778-S.B. or equivalent has been found satisfactory.FIG. 1 Cumulative Particle Size Distribution CurveD2862 102NOTE 2If
24、the apparent density of the sample has been determined, acalculated weight of sample equivalent to 200 6 10 mL may be used foreach of the riffled samples.7.2.3 Weigh each sample to the nearest 0.1 g.7.3 . Transfer the weighed sample to the top sieve.7.4 Install the sieve cover and transfer the assem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD28622010STANDARDTESTMETHODFORPARTICLESIZEDISTRIBUTIONOFGRANULARACTIVATEDCARBON 颗粒 活性炭 粒度 分布 标准 试验

链接地址:http://www.mydoc123.com/p-513663.html