ASTM D2549-2002(2012) Standard Test Method for Separation of Representative Aromatics and Nonaromatics Fractions of High-Boiling Oils by Elution Chromatography《洗脱色谱法分离高沸点油的典型芳烃和非芳烃.pdf
《ASTM D2549-2002(2012) Standard Test Method for Separation of Representative Aromatics and Nonaromatics Fractions of High-Boiling Oils by Elution Chromatography《洗脱色谱法分离高沸点油的典型芳烃和非芳烃.pdf》由会员分享,可在线阅读,更多相关《ASTM D2549-2002(2012) Standard Test Method for Separation of Representative Aromatics and Nonaromatics Fractions of High-Boiling Oils by Elution Chromatography《洗脱色谱法分离高沸点油的典型芳烃和非芳烃.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2549 02 (Reapproved 2012)Standard Test Method forSeparation of Representative Aromatics and NonaromaticsFractions of High-Boiling Oils by Elution Chromatography1This standard is issued under the fixed designation D2549; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the separation and determina-ti
3、on of representative aromatics and nonaromatics fractionsfrom hydrocarbon mixtures that boil between 232 and 538C(450 and 1000F). Alternative procedures are provided for theseparation of2gor10gofhydrocarbon mixture.NOTE 1Some components may not be eluted from the chromato-graphic column for some typ
4、es of samples under the conditions used inthis method.NOTE 2Test Method D2007 is an alternative method of separatinghigh-boiling oils into polar compounds, aromatics, and saturates fractions.1.2 An alternative procedure is provided to handle samplesboiling below 232C (450F), but whose 5 % point is a
5、bove178C (350F) as determined by Test Method D2887. Thisprocedure is given in Appendix X1.1.3 The values stated in acceptable SI units are to beregarded as the standard. The values given in parentheses areprovided for information purposes only.1.4 This standard does not purport to address all of the
6、safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and heal practices and determine the applicabilityof regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2007 Test Method for Characteri
7、stic Groups in RubberExtender and Processing Oils and Other Petroleum-Derived Oils by the Clay-Gel Absorption Chromato-graphic MethodD2425 Test Method for Hydrocarbon Types in MiddleDistillates by Mass SpectrometryD2786 Test Method for Hydrocarbon Types Analysis ofGas-Oil Saturates Fractions by High
8、 Ionizing VoltageMass SpectrometryD2887 Test Method for Boiling Range Distribution ofPetroleum Fractions by Gas ChromatographyD3239 Test Method for Aromatic Types Analysis of Gas-Oil Aromatic Fractions by High Ionizing Voltage MassSpectrometry3. Terminology3.1 Definitions of Terms Specific to This S
9、tandard:3.1.1 aromatics fractionthe portion of the sample des-orbed with the polar eluants. The aromatics fraction maycontain aromatics, condensed naphthenic-aromatics, aromaticolefins, and compounds containing sulfur, nitrogen, and oxy-gen atoms.3.1.2 nonaromatics fractionthe portion of the samplee
10、luted with n-pentane. The nonaromatics fraction is a mixtureof paraffinic and naphthenic hydrocarbons if the sample is astraight-run material. If the sample is a cracked stock, thenonaromatics fraction will also contain aliphatic and cyclicolefins.4. Summary of Test Method4.1 A weighed amount of sam
11、ple is charged to the top of aglass chromatographic column packed with activated bauxiteand silica gel. n-Pentane is added to the column to elute thenonaromatics. When all of the nonaromatics are eluted, thearomatics fraction is eluted by additions of diethyl ether,chloroform, and ethyl alcohol.4.2
12、The solvents are completely removed by evaporation,and the residues are weighed and calculated as the aromaticsand nonaromatics fractions of the sample.5. Significance and Use5.1 The determination of compound types by mass spec-trometry requires, in some instances, a preliminary separationof the pet
13、roleum sample into representative aromatics andnonaromatics fractions, as in Test Methods D2425, D2786, and1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0C on Liquid Chromatography.Current
14、edition approved April 15, 2012. Published April 2012. Originallyapproved in 1966. Last previous edition approved in 2007 as D254902(2007).DOI: 10.1520/D2549-02R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Boo
15、k of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.D3239. This test method provides a suitable separation tech-nique for this applica
16、tion.6. Apparatus6.1 Chromatographic Columns, as shown in Fig. 1. Differ-ent chromatographic columns are provided for the analysis of2 and 10-g samples.6.2 Beakers, 100, 250, and 600-mL, inverted-rim type.36.3 Steam Bath.6.4 Electric Vibrator, for packing column.6.5 Weighing Bottles or Erlenmeyer Fl
17、asks, 25 and 50 mL.7. Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall beused in this test. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such sp
18、ecifications are available.4Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Bauxite,520 to 60-mesh. Before use, activate thebauxite by heating at 538C (1000F) for 16 h. T
19、ransfer theactivated material to an airtight container while still hot andprotect thereafter from atmospheric moisture.7.3 Chloroform.(WarningToxic. May be fatal if swal-lowed.)3The sole source of supply of the beakers known to the committee at this timeis Kontes Glass Co., Vineland, NJ; order “Anti
20、-Creep” beakers and refer to DrawingNo. 9413-A. If you are aware of alternative suppliers, please provide thisinformation to ASTM International Headquarters. Your comments will receivecareful consideration at a meeting of the responsible technical committee1, whichyou may attend.4Reagent Chemicals,
21、American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For Suggestions on the testing of reagents notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formu
22、lary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.5The sole source of supply of the bauxite known to the committee at this timeis Porocel Corp., Little Rock, AR. If you are aware of alternative suppliers, pleaseprovide this information to ASTM International Headquarters. Your comments w
23、illreceive careful consideration at a meeting of the responsible technical committee1,which you may attend.FIG. 1 Chromatographic ColumnsD2549 02 (2012)27.4 Cleaning SolutionChromic-sulfuric acid.(WarningCauses severe burns.Arecognized carcinogen, strong oxidizer,contact with organic material may ca
24、use fire.)7.5 Diethyl Ether, anhydrous. (WarningExtremely flam-mable.) The ethyl ether used in this test method should be freeof peroxides as determined by the procedure in “ReagentChemical, American Chemical Society Specifications.”7.6 Ethyl Alcohol, denatured, conforming to Formula 2B ofthe U.S. B
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD254920022012STANDARDTESTMETHODFORSEPARATIONOFREPRESENTATIVEAROMATICSANDNONAROMATICSFRACTIONSOFHIGHBOILINGOILSBYELUTIONCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-513059.html