ASTM D2269-2010 Standard Test Method for Evaluation of White Mineral Oils by Ultraviolet Absorption《紫外线吸收法评估白色矿物油的标准试验方法》.pdf
《ASTM D2269-2010 Standard Test Method for Evaluation of White Mineral Oils by Ultraviolet Absorption《紫外线吸收法评估白色矿物油的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2269-2010 Standard Test Method for Evaluation of White Mineral Oils by Ultraviolet Absorption《紫外线吸收法评估白色矿物油的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2269 10Standard Test Method forEvaluation of White Mineral Oils by Ultraviolet Absorption1This standard is issued under the fixed designation D2269; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method describes a procedure for the exami-nation and evaluation of NF and USP grade white mineral oils.1.2 This te
3、st method is not applicable to oils containingadditives soluble in dimethyl sulfoxide (DMSO) that exhibitfluorescence or fluorescence quenching properties.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard doe
4、s not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see
5、 7.1.1-7.1.3.2. Referenced Documents2.1 ASTM Standards:2D1840 Test Method for Naphthalene Hydrocarbons inAvia-tion Turbine Fuels by Ultraviolet SpectrophotometryE131 Terminology Relating to Molecular SpectroscopyE275 Practice for Describing and Measuring Performanceof Ultraviolet and Visible Spectro
6、photometers2.2 Other Standard:U.S. Pharmacopeia USP XIII/National Formulary (NFXVIII)33. Terminology3.1 Definitions:3.1.1 For definitions of terms and symbols relating toabsorption spectroscopy see Terminology E131. Terms ofparticular significance are the following:3.1.2 radiant energy, nenergy tran
7、smitted as electromag-netic waves.3.1.3 radiant power, P, nthe rate at which energy istransported in a beam of radiant energy.3.2 Definitions of Terms Specific to This Standard:3.2.1 absorbance, A, nthe logarithm to the base 10 of thereciprocal of the transmittance, T. In symbols:A 5 log101/T!52log1
8、0Twhere T is the transmittance as defined in 3.2.5.3.2.2 absorptivity, a, nthe absorbance divided by theproduct of sample pathlength and concentration. In symbols:a 5 A/bcwhereAis the absorbance as defined in 3.2.1, b is the samplepathlength as defined in 3.2.4, and c is the concentration asdefined
9、in 3.2.3.3.2.3 concentration, c, nthe quantity of sample expressedin grams per litre.3.2.4 sample pathlength, b, nthe distance in centimetres,measured in the direction of propagation of the beam of radiantenergy, between the surfaces of the specimen on which theradiant energy is incident and the sur
10、face of the specimen fromwhich it is emergent.3.2.5 transmittance, T, nthe ratio of the radiant powertransmitted by the mineral oil extract in its cell to the radiantpower transmitted by the solvent control in its cell. Expressedby:T 5 Pe/Pcwhere Peis the radiant power transmitted by the mineral oil
11、extract and Pcis the radiant power transmitted by the solventcontrol.4. Summary of Test Method4.1 A sample of oil is extracted with dimethyl sulfoxide andthe ultraviolet absorbance of the extract is determined in therange from 260 to 350 nm. The absorbance is compared withthat of a naphthalene stand
12、ard.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0F on Absorption Spectroscopic Methods.Current edition approved May 1, 2010. Published June 2010. Originallyapproved in 1964. Last previous
13、 edition approved in 2005 as D226999(2005).DOI: 10.1520/D2269-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM webs
14、ite.3Available from The United States Pharmacopeia (USP), 12601 TwinbrookParkway, Rockville, MD 20852.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Significance a
15、nd Use5.1 The ultraviolet absorption of white mineral oils is usedto determine their suitability for use in food, drug, andcosmetic applications.5.2 The U.S. Pharmacopeia and the National Formularyspecifications for mineral oil require the measurement ofultraviolet absorption.6. Apparatus6.1 Spectro
16、photometer, equipped to handle liquid samplesin 1-cm path length cells. The instrument shall be capable ofmeasuring absorbance with a repeatability of 61.0 % or betterfrom an average at the 0.4 absorbance level in the spectralregion near 290 nm with a nominal band width of 1 nm or less.NOTE 1For rec
17、ommended methods of testing spectrophotometers tobe used in this test method refer to Practice E275.6.2 Fused Quartz Cells, two, having path lengths of 1.00 60.005 cm, or better. The distance in centimetres does notinclude the thickness of the cell in which the sample iscontained.6.3 Separatory Funn
18、els, glass-stoppered, of sufficient ca-pacity to perform the necessary extractions in the procedure,equipped with TFE-fluorocarbon stopcocks or other suitablestopcocks that will not contaminate the solvents used.7. Reagents and Materials7.1 Solvents:7.1.1 Normal HexanePure grade, having an ultraviol
19、etlight absorbance not exceeding 0.02 down to 260 nm whenmeasured in a 1-cm cell (WarningNormal hexane is ex-tremely flammable, harmful if inhaled. May produce nerve celldamage.) The purity shall be such that the solvent control asdefined in 8.3 shall have an absorbance curve compared towater showin
20、g no extraneous impurity peaks and no absor-bance exceeding that of dimethyl sulfoxide compared to waterat any wavelength in the range 260 to 350 nm, inclusive.7.1.2 Spectroscopic Grade 2,2,4Trimethylpentane(Isooctane)(WarningIsooctane is extremely flammable,harmful if inhaled.)NOTE 2For a suitable
21、isooctane and a procedure for preparingspectroscopic solvents from commercially available stocks, see TestMethod D1840.7.1.3 Dimethyl Sulfoxide(WarningDimethyl sulfoxideis combustible. Also it is rapidly absorbed through skin.) Foruse as spectroscopic solvent (see Note 3). Pure grade, clear,water wh
22、ite, 99.9 % dimethyl sulfoxide, m.p. 18.5C, with anabsorbance curve compared to water not exceeding 1.0 at 264nm and showing no extraneous impurity peaks in the wave-length range up to 350 nm when measured through a pathlength of 1 cm.NOTE 3This solvent can be purified by percolation through a 1.2-m
23、column of type CAL 1.68 by 0.420 mm (12 by 40 mesh) activatedcharcoal.4The column is 25 mm in diameter, drawn to 6.4 mm in diameterat the bottom and has a reservoir at the top for containing the liquid. Glasswool is placed in the bottom of the column, and about 13 mm of 0.707 to0.074 (25 to 200 mesh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD22692010STANDARDTESTMETHODFOREVALUATIONOFWHITEMINERALOILSBYULTRAVIOLETABSORPTION 紫外线 吸收 评估 白色 矿物油

链接地址:http://www.mydoc123.com/p-511351.html