ASTM D1986-2013 Standard Test Method for Determining the Apparent Viscosity of Polyethylene Wax《聚乙烯蜡表观粘度测量的标准试验方法》.pdf
《ASTM D1986-2013 Standard Test Method for Determining the Apparent Viscosity of Polyethylene Wax《聚乙烯蜡表观粘度测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1986-2013 Standard Test Method for Determining the Apparent Viscosity of Polyethylene Wax《聚乙烯蜡表观粘度测量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1986 91 (Reapproved 2012)D1986 13Standard Test Method forDetermining the Apparent Viscosity of Polyethylene Wax1This standard is issued under the fixed designation D1986; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the viscosity in centipoise of polyethylene wax using the B
3、rookfield LVT orLVF viscometer and thermosel system.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of
4、regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1E2251 Specification for ASTM Liquid-in-Glass ThermometersLiquid-in-Glass ASTM Thermometers with Low-HazardPrecision Liquids3. Terminology3.1 Definitions:3.1.1 polyethylene waxpolymerized ethylene with a molecular weight
5、2,000 to 10,000 and a density of 0.9 to 1.0 g/cm3. Thesepolymers can be oxidized or copolymerized but should have a melt point lower than 140C.3.1.2 viscositythe ratio of shear stress to shear rate. The viscosity of a liquid is a measure of the internal friction of the liquidin motion. The units of
6、viscosity is the pascal second. For a Newtonian liquid, the viscosity is constant at all shear rates. For anon-Newtonian liquid, viscosity will vary depending on shear rate.3.1.3 apparent viscositythe viscosity determined by this test method and expressed in millipascal seconds. Its value may varywi
7、th the spindle and rotational speed selected because many waxes are non-Newtonian.4. Significance and Use4.1 This test method is used to determine a physical property of a wax and may determine the utility of the wax, as well as beinga significant quality control test.5. Apparatus5.1 Brookfield Ther
8、mosel System, with LVT, LVF, or LVD 111 viscometer and SC 4-31 spindle.36. Calibration6.1 The viscometer is precalibrated using Newtonian fluids provided by the manufacturer. No zero adjustment is provided sinceexperience has shown that the zero point will not vary due to changes in the spring. The
9、viscometer and spindles are precisionequipment and should be kept from undue shock and mishandling. Physical damage to the instrument will often reveal itself aserratic or no oscillation of the pointer when the instrument, with or without the spindle in place, is operated in air. When operatingnorma
10、lly, the pointer will be stable and have free oscillation about the zero point in air.1 This test method is under the jurisdiction of ASTM Committee D21 on Polishes and is the direct responsibility of Subcommittee D21.02 on Raw Materials.Current edition approved Oct. 1, 2012Oct. 1, 2013. Published O
11、ctober 2012 October 2013. Originally approved in 1991. Last previous edition approved in 20072012 asD1986-91(2007).D1986-91(2012). DOI: 10.1520/D1986-91R12.10.1520/D1986-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For An
12、nual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from Brookfield Engineering Laboratories, Inc. 11 Commerce Boulevard, Middleboro, MA 02346.This document is not an ASTM standard and is intended only to provide the user of an
13、ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as publish
14、ed by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.2 The instrument may be further calibrated using standard reference fluids. Suitable fluids are available in nominal viscositiesup
15、to 15 000 mPas at 149C (300F).3 The procedure for instrument calibration using standard reference fluids is not encompassedby this test method. Results obtained using standard reference fluids should not deviate from the nominal viscosity by more than2 %.6.3 The temperature controller of the type re
16、commended for this procedure is factory calibrated and has control capability of60.5 % of the control point (61.0C at 175C). To further check the controller and further establish controller settings, use thefollowing procedure. Place a sufficient quantity of polyethylene wax in the sample container
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD19862013STANDARDTESTMETHODFORDETERMININGTHEAPPARENTVISCOSITYOFPOLYETHYLENEWAX 聚乙烯 表观 粘度 测量 标准 试验

链接地址:http://www.mydoc123.com/p-510783.html