ASTM D1510-2007 Standard Test Method for Carbon Black-Iodine Adsorption Number《炭黑—碘吸收值的标准试验方法》.pdf
《ASTM D1510-2007 Standard Test Method for Carbon Black-Iodine Adsorption Number《炭黑—碘吸收值的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1510-2007 Standard Test Method for Carbon Black-Iodine Adsorption Number《炭黑—碘吸收值的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1510 07Standard Test Method forCarbon BlackIodine Adsorption Number1This standard is issued under the fixed designation D 1510; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p
2、arentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the determination of the iodineadsorptio
3、n number of carbon black.1.1.1 Procedure A is the original procedure for this deter-mination.1.1.2 Procedure B specifies an increased sample mass ofcarbon black and volume of iodine solution (the ratio is thesame as in Procedure A) which results in a simplified formulafor the calculation of the iodi
4、ne number.1.2 The iodine adsorption number of carbon black has beenshown to decrease with sample aging. New SRB HT IodineStandards have been produced that exhibit stable iodinenumber upon aging. These SRB HT Iodine Standards arerecommended for daily monitoring (x-charts) of testing and forstandardiz
5、ation of iodine testing (see Section 8) when targetvalues cannot be obtained.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with i
6、ts use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1799 Practice for Carbon BlackSampling PackagedShipmentsD 1900 Pract
7、ice for Carbon BlackSampling Bulk Ship-mentsD 4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustriesD 4821 Guide for Carbon BlackValidation of TestMethod Precision and Bias3. Summary of Test Method3.1 A weighed sample of carbon black is
8、 treated with aportion of standard iodine solution and the mixture shaken andcentrifuged. The excess iodine is then titrated with standardsodium thiosulfate solution, and the adsorbed iodine is ex-pressed as a fraction of the total mass of black.4. Significance and Use4.1 The iodine adsorption numbe
9、r is useful in characterizingcarbon blacks. It is related to the surface area of carbon blacksand is generally in agreement with nitrogen surface area. Thepresence of volatiles, surface porosity, or extractables willinfluence the iodine adsorption number. Aging of carbon blackcan also influence the
10、iodine number.5. Apparatus5.1 Vials, glass, optically clear type, with polyethylenestoppers, 45 cm3.5.2 Gravity Convection Drying Oven, capable of maintain-ing 125 6 5C.5.3 Buret, either of the following may be used:5.3.1 Digital Buret, 25-cm3capacity, with 0.01-cm3incre-ment counter and zero reset
11、control, or5.3.2 Buret, glass 25-cm3, Class A, side-arm filling, gradu-ated in 0.05 cm3and with automatic zero.5.4 Repetitive Dispenser, 25-cm3capacity, 60.1% repro-ducibility and calibrated to within 60.03-cm3accuracy.5.5 Balance, analytical, with 0.1-mg sensitivity.5.6 Centrifuge, with minimum spe
12、ed of 105 rad/s (1000 r/min).5.7 Volumetric Flask, 2000-cm3with standard taper stopper.5.8 Funnel, large diameter, with standard taper joint to fitthe 2000-cm3flask.5.9 Glass Bottle, amber, 2000-cm3, with standard taperstopper.5.10 Glass Jug, approximate capacity 20-dm3.5.11 Stirrer, approximately 3
13、00 by 300 mm for mixing.1This test method is under the jurisdiction of ASTM Committee D24 on CarbonBlack and is the direct responsibility of Subcommittee D24.21 on Carbon BlackSurface Area and Related Properties.Current edition approved July 1, 2007. Published July 2007. Originally approvedin 1957.
14、Last previous edition approved in 2006 as D 1510 06a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyrig
15、ht ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.12 Stirrer, approximately 100 by 100 mm for titrating.5.13 Desiccator.5.14 Miscellaneous Class A Glassware, and equipmentnecessary to carry out the test as written.5.15 Mechanical Shaker, wit
16、h at least 1 in. stroke length anda minimum of 240 strokes/min.5.16 Automatic Titrator.5.17 Redox Electrode, combined platinum ring electrodewith an Ag/AgCl/KCl reference electrode and a ceramic frit.5.18 Volumetric Flask, 500 cm3with standard taper stopper.6. Reagents and Solutions6.1 Purity of Rea
17、gentsUnless otherwise stated, all chemi-cals shall be of reagent grade.6.2 The preparation of the solutions listed below is de-scribed in Annex A1. Pre-mixed 0.0473 N iodine solution and0.0394 N sodium thiosulfate may be purchased from commer-cial sources. It is recommended that the normality of pre
18、-mixedsolutions be verified before use.6.3 Iodine Solution, c(I2) = 0.02364 mol/dm3(0.0473 N),containing 57.0 g potassium iodide Kl per dm3.6.4 Potassium Iodate Solution, c(KIO3) = 0.00657 mol/dm3(0.0394 N) containing 45.0 g potassium iodide per dm3.6.5 Potassium Dichromate Solution,c(K2Cr2O7)=0.006
19、567 (0.0394 N), containing 1.932 g potassium dichromate(certified/traceable primary standard) per dm3.(WarningPotassium dichromate is carcinogenic.)6.6 Sodium Thiosulfate Solution, c(Na2S2O3) = 0.0394 mol/dm3(0.0394 N), containing 5 cm3n-amyl alcohol per dm3.6.7 Sulfuric Acid,10%.6.8 Soluble Starch
20、Solution, 1 %, containing 0.02 g salicylicacid per dm3.6.9 Water.7. Standardization of Solutions7.1 Sodium Thiosulfate, 0.0394 N (60.00008):7.1.1 Use potassium dichromate solution as follows:7.1.2 Measure approximately 20 cm3of 10 % potassiumiodide (see A1.4) solution into a small graduated cylinder
21、 andtransfer to a 250 cm3iodine flask with a ground glass stopper.7.1.3 Measure approximately 20 cm3of 10 % sulfuric acidsolution (see A1.5) into a small graduated cylinder and add tothe KI solution in the iodine flask. The mixture should remaincolorless.NOTE 1If a yellow color should develop, disca
22、rd this KI solution.7.1.4 Using a 20 cm3pipet, transfer 20 cm3of standard0.0394 N potassium dichromate solution (see A1.8) into the250 cm3iodine flask, replace stopper, swirl, and place in thedark for 15 min.7.1.5 Titrate the contents of the iodine flask against the newsodium thiosulfate solution fo
23、llowing 7.2.6 and 7.2.7.7.2 Sodium Thiosulfate, 0.0394 N (60.00008):7.2.1 Use potassium iodate/iodide solution as follows:7.2.2 Pipet exactly 20 cm3of 0.0394 N potassium iodate/iodide solution into a 250-cm3iodine flask.7.2.3 Measure approximately 5 cm3of 10 % sulfuric acidinto a small graduated cyl
24、inder and add to the iodate/iodidesolution.7.2.4 Cap immediately and mix thoroughly.7.2.5 Titrate the contents of the iodine flask against the newsodium thiosulfate solution following 7.2.6 and 7.2.7.7.2.6 Digital Buret:7.2.6.1 Switch the digital buret to fill mode, fill the reservoirwith unstandard
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD15102007STANDARDTESTMETHODFORCARBONBLACKIODINEADSORPTIONNUMBER 炭黑 吸收 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509927.html