ASTM D1212-1991(2007) Standard Test Methods for Measurement of Wet Film Thickness of Organic Coatings《有机涂层湿膜厚度的测试方法》.pdf
《ASTM D1212-1991(2007) Standard Test Methods for Measurement of Wet Film Thickness of Organic Coatings《有机涂层湿膜厚度的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1212-1991(2007) Standard Test Methods for Measurement of Wet Film Thickness of Organic Coatings《有机涂层湿膜厚度的测试方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1212 91 (Reapproved 2007)Standard Test Methods forMeasurement of Wet Film Thickness of Organic Coatings1This standard is issued under the fixed designation D 1212; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of wet filmthickness of organic coatings such as paint, varnish, a
3、ndlacquer. Two methods are described as follows:1.1.1 In Test Method A, the Wet Film Thickness Gage(English or Metric graduation (see 5.1) is used to measure wetfilm thicknesses up to 60 mils on the English scale series, andup to 700 m on the metric scale series (Sections 5-8).1.1.2 In Test Method B
4、, the Pfund Gage is used to measurewet film thicknesses up to 14.2 mils (360 m) (Sections 9-13).1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any
5、, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 823 Practices for Producing Films of Uniform Thic
6、knessof Paint, Varnish, and Related Products on Test Panels3. Summary of Test Methods3.1 The material is applied in the laboratory to plane, rigidtest panels or in the field to the surface being coated. The wetfilm thickness is determined as quickly as possible to reduceshrinkage due to solvent loss
7、.3.2 In Test Method A, a gage with one eccentric and twoconcentric wheels is rolled over the surface and the point wherethe eccentric wheel first touches the wet film is determined.3.3 In Test Method B, a gage with a convex lower surface ispushed into the wet film until the center touches the substr
8、ate.The diameter of the spot of wet coating left on the convexsurface is measured and the film thickness calculated from thediameter of the spot and the radius of curvature.4. Significance and Use4.1 Wet film thickness measurements aid in the predictionof dry film thickness. In instances where dry f
9、ilm thicknesscannot be measured nondestructively, wet film thickness isfrequently specified. Also, the ability to determine wet filmthickness during application can provide the opportunity tocorrect the application procedures.TEST METHOD A5. Apparatus5.1 Wet Film Thickness GageTwo versions of the ga
10、ge arenow in use:3The original design as shown in Fig. 1 and a laterdesign as shown in Fig. 2. Both designs consists of an eccentriccenter wheel supported by two concentric wheels so as toprovide two scales that are bilaterally symmetrical.As the gageis rolled on the film, there is a change in clear
11、ance between thewet film and the eccentric wheel. The point at which the filmfirst touches the center wheel measures the thickness of thefilm.5.2 The later design shown in Fig. 2, moves the eccentricwheel from between the concentric wheels, as shown in Fig. 1,to the outside of the gage and closer to
12、 one of the concentricwheels. Gage reading errors of parallax across the gage areeliminated as the two scales are placed directly on the eccentricwheel and errors when measuring on uneven support surfacesare reduced by placing the eccentric wheel closer to one of thesupporting concentric wheels.5.3
13、Best precision is obtained when using the near linearcentral portion of each scale, constituting about 80 % of itstotal range as shown in the diagram in Fig. 1 and Fig. 2.Therefore, the range of the particular gage selected for useshould be such that the measured film thickness falls within,and pref
14、erably toward the center of the middle 80 % of eachscale. Gages are available covering the following ranges inmils and microns:1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and Applications and are the directresponsibility of Subcommitt
15、ee D01.23 on Physical Properties of Applied PaintFilms.Current edition approved June 1, 2007. Published June 2007. Originallyapproved in 1952. Last previous edition approved in 2001 as D 1212 - 91 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Se
16、rvice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Both versions of this gage (Interchemical (INMONT) and Model “C”), arecovered by U.S. Patents 2 507 592 and 3 128 558, and are issued to Maynard R.Euverard.
17、 Interested parties are invited to submit information regarding theidentification of acceptable alternatives to this patented item to the Committee onStandards, ASTM Headquarters. Your comments will receive careful considerationat a meeting of the responsible technical committee, which you may atten
18、d.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Range, milsSmallestGraduation, mils0to2 0.10to4 0.22to12 0.510 to 30 1.020 to 60 2.0Range, mSmallestGraduation, m0to40 2.00 to 100 5.0050 to 250 10.00200 to 700 25.006. Procedure6.1 A
19、pply the material in accordance with Practices D 823to suitable plane rigid panels of area sufficiently large to permitfilm thickness measurements at least 25 mm (1 in.) from anyedge. Determine the film thickness immediately after applica-tion.6.2 Support the test panels on a suitable level base in
20、sucha way that there will be no movement or spring of the panelsduring the film thickness measurements. Place the gage on thewet film so that the minimum marking is at the top and thegreatest clearance between the eccentric wheel and the film isdirectly over the wet film. Roll the gage over the film
21、 one-halfrevolution in one direction toward the minimum marking onthe gage and repeat in the opposite direction. Read the pointsat which the coating first makes contact with the eccentricwheel and determine the mean which is considered as onereading.6.3 If the coating contains a solvent that evapora
22、tes rapidlyor if the solids content is low, make at least a second separatereading on a freshly applied film and calculate the mean of theseparate readings.7. Report7.1 Report the mean of the separate readings and the rangeand smallest graduation of the gage used.8. Precision48.1 In an interlaborato
23、ry study of this test method, in whichtwo operators in at least six laboratories made measurementswith the 0- to 2- and 0- to 4-mil gages on three materials,applied at two film thicknesses, the pooled within-laboratorystandard deviation was found to be 0.12 mils with 34 df and the4Supporting data ha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD121219912007STANDARDTESTMETHODSFORMEASUREMENTOFWETFILMTHICKNESSOFORGANICCOATINGS 有机 涂层 厚度 测试 方法

链接地址:http://www.mydoc123.com/p-509458.html