ASTM C663-1998(2003)e2 Standard Specification for Asbestos-Cement Storm Drain Pipe《石棉水泥排雨水管道标准规范》.pdf
《ASTM C663-1998(2003)e2 Standard Specification for Asbestos-Cement Storm Drain Pipe《石棉水泥排雨水管道标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C663-1998(2003)e2 Standard Specification for Asbestos-Cement Storm Drain Pipe《石棉水泥排雨水管道标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 663 98 (Reapproved 2003)e2Standard Specification forAsbestos-Cement Storm Drain Pipe1This standard is issued under the fixed designation C 663; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTEWarning notes were editorially moved into the standard
3、 text in July 2003.e2NOTEAsbestos warning was moved from 7.2 to 1.3 in September 2004.1. Scope1.1 This specification covers asbestos-cement pipe intendedfor use in storm-water drainage of highways, airports, farms,foundations, and other similar drainage systems.1.2 The values stated in SI units are
4、to be regarded as thestandard. The values stated in parentheses are for informationonly.1.3 WarningBreathing of asbestos dust is hazardous.Asbestos and asbestos products present demonstrated healthrisks for users and for those with whom they come into contact.In addition to other precautions, when w
5、orking with asbestos-cement products, minimize the dust that results. For informa-tion on the safe use of chrysoltile asbestos, refer to “Safe Useof Chrysotile Asbestos: A Manual on Preventive and ControlMeasures.”21.4 This standard does not purport to address all of thesafety concerns, if any, asso
6、ciated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 1.3 for aspecific hazard warning.2. Referenced Documents2.1 ASTM Standards:3C 150 Specification
7、 for Portland CementC 458 Test Method for Organic Fiber Content of Asbestos-Cement ProductsC 500 Test Methods for Asbestos-Cement PipeC 595 Specification for Blended Hydraulic CementsD 2946 Terminology for Asbestos and Asbestos-CementProducts2.2 Federal Standard:Fed. Std. No. 123 Marking for Shipmen
8、t (Civil Agencies)42.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage42.4 Other Standards:Uniform Freight Classification Rules5National Motor Freight Classification Rules63. Terminology3.1 Definitions:3.1.1 coupling, nin asbestos-cement conduit, sewer, un-derdrain and storm drain pip
9、ecomponent made from a largerdiameter pipe of the same type or class, or of Type II and ahigher class, or produced otherwise to yield at least equalperformance, for joining asbestos-cement pipe that whenproperly installed, forms a silt-tight joint, allows alignmentcorrections and slight changes in d
10、irection, and provides anassembled joint equivalent in serviceability and strength to thepipe sections. Alternatively, for storm drain couplings, plasticsleeves that, when properly installed develop sufficient tight-ness to prevent the surrounding soil from entering the drain,may be used as coupling
11、s.3.1.2 lot, nfor pipe sizes 525 mm (21 in.) in diameter andsmaller, each 300 lengths of pipe or less, of identical class andsized manufactured on each machine during a 24-h period. Forpipe larger than 525 mm (21 in.), each 300 lengths of pipe orless, of identical class and size manufactured on each
12、 machineduring a period of consecutive working days not exceedingseven days.3.1.3 Additional terminology is given in TerminologyD 2946.4. Classification4.1 The types of pipe shall be shown as Type I and Type IIcorresponding to the chemical requirements given in 10.1.1This specification is under the
13、jurisdiction of ASTM Committee C17 onFiber-Cement Products and is the direct responsibility of C17.03 on Asbestos-Cement Products.Current edition approved Jan. 10, 2003. Published July 2003. Originallyapproved in 1970. Last previous edition approved in 1998 as C 663 98.2Available from The Asbestos I
14、nstitute, http:/ Book of ASTM Standards, Vol 04.01.4Available from Standardization Documents Order Desk, Bldg. 4, Section D,700 Robbins Ave., Philadelphia, PA 19111-5094 Attn: NPODS.5Available from the Uniform Classification Commission, Room 1106, 222 S.Riverside Plaza, Chicago, IL 60606.6Available
15、from National Motor Freight Inc., 1616 “P” St. NW, Washington, DC20036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 Asbestos-cement storm drain pipe furnished under thisspecification shall be designated as Class II, III, 2500D
16、, IV, andV. The corresponding strength requirements are prescribed inTable 1. The D1load is the crushing test load expressed innewtons per linear metre per of diameter. (The D load is thecrushing test load expressed in pounds-force per linear ft per ftof diameter.) The pipe shall be furnished in 10,
17、 15, 20, 25, 30,36, 38, 41, 46, 51, 53, 61, 69, 76, 84, 91, 99 and 107-cm sizes(4, 6, 8, 10, 12, 14, 15, 16, 18, 20, 21, 24, 27, 30, 33, 36, 39 and42-in. sizes).5. Materials and Manufacture5.1 Asbestos-cement storm drain pipe shall be composed ofan intimate mixture of portland cement or portland bla
18、st-furnace slag cement meeting Specification C 150 or portlandslag or pozzolan cements conforming to Specification C 595.The mixture shall not contain more than 0.2 % of non-deleterious organic components as determined by Test MethodC 458. The material shall be of laminar construction formedunder pr
19、essure to a homogeneous structure and cured to meetthe physical and chemical requirements of this specification.6. Dimensions, Mass, and Permissible Variations6.1 The nominal length for asbestos-cement storm drainpipe shall be either 3 or 4 m (10 or 13 ft). A maximum of 15 %of the total footage of a
20、ny one size and type for any order maybe furnished, at the manufacturers option, in pipe lengthsshorter than specified nominal, but not shorter than2m(7ft);these shall be termed random lengths.6.2 A tolerance of 25 mm (61 in.) shall apply to nominalstandard lengths. Random lengths shall be classifie
21、d to 150 mm(+ 15025 mm) 6 in. (+ 4.91.0 in.) increments, allowing atolerance of 124 mm (+ 478 in.) and 1 in.6.3 The average inside diameter of the pipe may be less thanthe nominal size by not more than 6 mm (0.25 in.) or 112 %,whichever is greater.7. Sampling7.1 All material tested under this specif
22、ication shall be inair-dried condition in equilibrium with atmospheric moisture.7.2 For crushing tests, select one full length of pipe fromeach lot of each size, class, and type of pipe. Cut one testspecimen 30 cm (12 in.) long from the unmachined portion ofthe selected length of pipe. (Warningsee 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC66319982003E2STANDARDSPECIFICATIONFORASBESTOSCEMENTSTORMDRAINPIPE 石棉 水泥 雨水 管道 标准规范 PDF

链接地址:http://www.mydoc123.com/p-507948.html