ASTM C657-1993(2008) Standard Test Method for D-C Volume Resistively of Glass《玻璃直流体电阻系数的标准试验》.pdf
《ASTM C657-1993(2008) Standard Test Method for D-C Volume Resistively of Glass《玻璃直流体电阻系数的标准试验》.pdf》由会员分享,可在线阅读,更多相关《ASTM C657-1993(2008) Standard Test Method for D-C Volume Resistively of Glass《玻璃直流体电阻系数的标准试验》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 657 93 (Reapproved 2008)Standard Test Method forD-C Volume Resistivity of Glass1This standard is issued under the fixed designation C 657; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the dcvolume resistivity of a smooth, preferably polished, glass bymeasuring the resistanc
3、e to passage of a small amount of directcurrent through the glass at a voltage high enough to assureadequate sensitivity. This current must be measured understeady-state conditions that is neither a charging current nor aspace-charge, buildup polarization current.1.2 This test method is intended for
4、 the determination ofresistivities less than 1016Vcm in the temperature range from25C to the annealing point of the glass.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-
5、priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 5.2. Referenced Documents2.1 ASTM Standards:2D 257 Test Methods for DC Resistance or Conductance ofInsulating MaterialsD 374 Test Methods for Thickne
6、ss of Solid Electrical Insu-lationD 1711 Terminology Relating to Electrical InsulationD 1829 Test Method for Electrical Resistance of CeramicMaterials at Elevated Temperatures (Discontinued 2001)33. Summary of Test Method3.1 The dc volume resistance is measured in accordancewith Test Methods D 257,
7、with the specimen located in aheating chamber with adequate temperature control, electricalshielding and insulation of the sample leads as described inTest Method D 1829.4. Significance and Use4.1 This experimental procedure yields meaningful data forthe dc volume resistivity of glass. It is designe
8、d to minimizespace charge, buildup polarization effects, and surface conduc-tances. The temperature range is limited to room temperatureto the annealing point of the specimen glass.5. Cautions5.1 Thermal emfs should be avoided. Connections involv-ing dissimilar metals can cause measurement difficult
9、ies. Evencopper-copper oxide junctions can produce high thermal emfs.Clean, similar metals should be used for electrical junctions.Platinum is recommended. Welded or crimped connectionsrather than soldered joints avoid difficulties. Specimen elec-trodes shall have sufficient cross section for adequa
10、te electricalconductance.6. Apparatus6.1 Resistance-Measuring Devices, and the possible prob-lems associated with them are discussed thoroughly in Section9 and Appendixes A1 and A3 of Test Methods D 257. Furtherdiscussion of electrometer circuitry is covered in Annex A1 tothis test method.6.2 Heatin
11、g Chamber (Fig. 1)For heating the specimen, asuitable electric furnace shall be used. The construction of thefurnace shall be such that the specimen is subjected to auniform heat application with a minimum of temperaturefluctuation. An adequate muffle should be provided to shieldthe specimen from di
12、rect radiation by the heating elements.This may be made of a ceramic such as aluminum oxide orequivalent. A grounded metallic shield shall also be providedwithin the furnace, preferably of silver, stainless steel, orequivalent, to isolate electrically the specimen test circuit fromthe heating elemen
13、t. Furnaces for more than one specimen canbe constructed. The control thermocouple may be located inthe heating chamber outside the metallic shield, as shown inFig. 1, or inside the metallic shield.1This test method is under the jurisdiction of ASTM Committee C14 on Glassand Glass Products and is th
14、e direct responsibility of Subcommittee C14.04 onPhysical and Mechanical Properties.Current edition approved April 1, 2008. Published December 2008. Originallyapproved in 1970. Last previous edition approved in 2003 as C 657 93 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.
15、org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International,
16、100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.3 Two Flat Contacting Electrodes, smaller in diameterthan the specimen electrodes (see 7.6), shall be used tosandwich the specimen. Sufficient thickness should be used tomaintain an adequate pressure and to provide
17、 heat equalizationbetween the specimen and the contacting electrodes.6.3.1 Fig. 2 shows the specimen setup in the heatingchamber. The bottom electrode shall be placed at the end of ametal rod and shall support the specimen in the center of thefurnace. The unguarded specimen electrode, No. 3 of Fig.
18、3,shall be placed in contact with this bottom contacting elec-trode. The top contacting electrode shall be placed on theguarded, specimen electrode, No. 1 of Fig. 3. This topcontacting electrode has leads connected to an off-center metalrod. The specimen guard electrode, No. 2 of Fig. 3, shall becon
19、nected to the second off-center metal rod with platinumwire or strap. One end shall be connected to the specimenguard electrode; the other end shall be connected to the metalrod.6.3.2 All rods should be supported by insulation outside thefurnace in a cool zone to minimize electrical leakage atelevat
20、ed temperatures.6.3.3 Fig. 4 shows a top view of the specimen setup in theheating chamber.6.4 A Temperature-Control System should be provided sothat temperature-time fluctuations within the heating chamberare less than 0.01 T (where T is the temperature in degreesCelsius), during the time interval w
21、hen resistance measure-ments are made. Two thermocouples should be used foraccurate temperature readings, one in the heating chamber,supplying the emf to the temperature controller and the otheron the guard ring of the specimen. The latter should be used tomeasure the specimen temperature as instruc
22、ted in the Appa-ratus section (Temperature-Control Device) of Test MethodD 1829.7. Test Specimen7.1 The Test Specimens section (Volume Resistance orConductance Determination) of Test Methods D 257 describesin detail the specimen requirements. To quote in part, “The testspecimen may have any practica
23、l form that allows the use of athird electrode, when necessary, to guard against error fromsurface effects.” For practical reasons, a flat disk or square thatis easy to set up in a furnace box is recommended. Otherconfigurations are possible. The descriptions will apply to flatsamples but can be mod
24、ified for other configurations. Recom-mended limitations in the diameter of a disk are 40 to 130 mm.This is not a critical dimension as the effective area ofmeasurements is defined by the area of the applied electrodes,as stated in 7.7.7.2 As the electrical properties of glass are dependent on theth
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC65719932008STANDARDTESTMETHODFORDCVOLUMERESISTIVELYOFGLASS 玻璃 流体 电阻 系数 标准 试验 PDF

链接地址:http://www.mydoc123.com/p-507931.html