1、Designation: C 562 91 (Reapproved 2005)An American National StandardStandard Test Method forMoisture in a Graphite Sample1This standard is issued under the fixed designation C 562; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method provides
3、a practical determination forthe percentage of moisture in a graphite sample.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determ
4、ine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 561 Test Method for Ash in a Graphite Sample3. Significance and Use3.1 This test method is feasible only for the volatile mois-ture present on the graphite due to adsorption from theatmosphere
5、and is not intended to give representative moisturedata for graphite that has been exposed to liquid watercontamination.4. Interferences4.1 Final weights (and therefore percent moisture values)may be influenced by the following:4.1.1 Type and condition of desiccant.4.1.2 Ambient relative humidity at
6、 the time of the test.4.1.3 Timing and procedure for moving samples from des-iccator to the balance.4.1.4 Adsorptivity of the graphite sample relative to theadsorptivity of the desiccant used.4.1.5 Residency time in the desiccator.5. Apparatus5.1 Alumina Ceramic or Platinum Crucible or Dish, suit-ab
7、le for holding sample (subsequently called sample holder).5.2 Analytical Balance, capable of weighing to 60.0002 g.5.3 Drying Oven, air convection type, capable of beingcontrolled to 110 6 2C (2306 4F).5.4 Desiccator, charged with indicating desiccant.6. Sampling6.1 Samples may be solid or particula
8、te. Solid bodies maybe sampled by removing one or more solid pieces from thebody by, for example, sawing, turning, milling, or fracturing.Particulate samples may be generated from solid bodies bydrilling, using a carbide drill to minimize contamination, or byother crushing and grinding methods.7. Pr
9、ocedure7.1 Tare a dried sample holder using an analytical balance.Weigh a 25 to 50-g sample into the tared sample holder andreweigh both. (Perform all weighings to a precision of60.002 g.)7.2 Place the sample holder containing the sample in adrying oven maintained at 110 6 2C (230 6 4F) for 2 h.Remo
10、ve from the oven and immediately place in the desicca-tor. When the sample has reached room temperature, removefrom the desiccator and weigh immediately.7.3 Repeat the procedure prescribed in 7.2 until a constantweight of 60.002 g is achieved.7.4 The dried sample may be reserved for ash determina-ti
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC56219912005STANDARDTESTMETHODFORMOISTUREINAGRAPHITESAMPLE 石墨 样品 水分 检测 方法 PDF

链接地址:http://www.mydoc123.com/p-467035.html