ASTM C414-2003(2008) Standard Test Method for Working Setting and Service Strength Setting Times of Chemically Setting Chemical-Resistant Silicate and Silica Mortars《化学凝固的耐化学腐蚀硅酸盐及.pdf
《ASTM C414-2003(2008) Standard Test Method for Working Setting and Service Strength Setting Times of Chemically Setting Chemical-Resistant Silicate and Silica Mortars《化学凝固的耐化学腐蚀硅酸盐及.pdf》由会员分享,可在线阅读,更多相关《ASTM C414-2003(2008) Standard Test Method for Working Setting and Service Strength Setting Times of Chemically Setting Chemical-Resistant Silicate and Silica Mortars《化学凝固的耐化学腐蚀硅酸盐及.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 414 03 (Reapproved 2008)Standard Test Method forWorking, Setting, and Service Strength Setting Times ofChemically Setting Chemical-Resistant Silicate and SilicaMortars1This standard is issued under the fixed designation C 414; the number immediately following the designation indicates
2、 the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the
3、Department of Defense.1. Scope1.1 This test method offers a means of determining theworking time, setting time, and service strength setting time ofchemically setting, chemical-resistant silicate and silica mor-tars.NOTE 1For chemical-resistant resin mortars refer to Test MethodsC 308.1.2 The values
4、 stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with it
5、s use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 308 Test Methods for Working, Initial Setting, and Ser-vice Strength
6、Setting Times of Chemical-Resistant ResinMortarsC 579 Test Methods for Compressive Strength of Chemical-Resistant Mortars, Grouts, Monolithic Surfacings, andPolymer ConcretesC 904 Terminology Relating to Chemical-Resistant Non-metallic Materials3. Terminology3.1 DefinitionsFor definitions of terms u
7、sed in these testmethods, see Terminology C 904.4. Significance and Use4.1 This test method offers a means of determining theworking time, initial setting time and service strength settingtime of chemically setting chemical-resistant silicate and silicamortars.5. Apparatus5.1 Equipment, capable of w
8、eighing materials or specimensto 60.3 % accuracy.5.2 Mixing PanA metal or porcelain enameled pan mea-suring approximately 8 by 8 by 2 in. (200 by 200 by 50 mm)deep.5.3 TrowelA bricklayers triangular trowel approximately4 in. (100 mm) in length.5.4 Aluminum Foil DishA flat-bottomed container 214 in.(
9、60 mm) in diameter by58 in. (16 mm) high. An aluminum foildish for milk analysis is suitable.5.5 Gillmore NeedleThe Gillmore needle shall conform tothe following requirements:Initial NeedleWeight 113.4 6 0.5 gDiameter 0.083 6 0.002 in.Final NeedleWeight 453.6 6 0.5 gDiameter 0.042 6 0.002 in.1This t
10、est method is under the jurisdiction of ASTM Committee C03 onChemical-Resistant Nonmetallic Materials and are the direct responsibility ofSubcommittee C03.01 on Mortars and Carbon Brick.Current edition approved June 1, 2008. Published July 2008. Originally approvedin 1958. Last previous edition appr
11、oved in 2003 as C 414 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 B
12、arr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.5.1 The needle tips shall be cylindrical for a distance ofabout316 in. (4.8 mm). The needle ends shall be plane and atright angles to the axis of the rod and shall be maintained in aclean condition. The Gillmore needles
13、 should preferably bemounted as shown in Fig. 1.6. Temperature Conditions6.1 All material used in this test method shall be stored forat least 16 h prior to use at the standard test temperature of 736 4F (23 6 2C). The standard temperature for the working,initial setting, and service strength settin
14、g times shall be 73 64F.6.2 The relative humidity of the surrounding air shall bekept below 80 % during mixing of the mortar and conditioningof the specimens.6.3 Other test temperatures are acceptable upon agreementbetween the manufacturer and user, provided that they arereported with the test data.
15、7. Preparation of Mortar7.1 Prepare a 4.4 lb (2000 g) sample of mortar using theproportionate amounts of powder filler and liquid recom-mended by the manufacturer. If the proportions are specified byvolumes, weigh the volumes and report the correspondingweights. Pour the liquid into the mixing pan a
16、nd gradually addthe powder filler to the liquid while mixing with the trowel.Note and record the time mixing begins. Thoroughly mix themass until a uniform mixture is secured. The total mixing timeshall be in accordance with the manufacturers recommenda-tion.7.2 Fill an aluminum dish and strike off
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC41420032008STANDARDTESTMETHODFORWORKINGSETTINGANDSERVICESTRENGTHSETTINGTIMESOFCHEMICALLYSETTINGCHEMICALRESISTANTSILICATEANDSILICAMORTARS

链接地址:http://www.mydoc123.com/p-466521.html