《ASTM C400-1998(2013)e1 Standard Test Methods for Quicklime and Hydrated Lime for Neutralization of Waste Acid《中和废酸用生石灰和熟石灰的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C400-1998(2013)e1 Standard Test Methods for Quicklime and Hydrated Lime for Neutralization of Waste Acid《中和废酸用生石灰和熟石灰的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C400 98 (Reapproved 2013)1Standard Test Methods forQuicklime and Hydrated Lime for Neutralization of WasteAcid1This standard is issued under the fixed designation C400; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTECorrected erroneous references in 7.4.2.1 and 7.4.3.1 in December 2017.1. Scope1.1 This test method covers the tes
3、ting of quicklime andhydrated lime for use in the treatment of waste acid solutionsand includes the characterization of the liming material and ofthe acid waste.NOTE 1When agreed upon by the manufacturer and the purchaser,this method may be used directly to evaluate the lime requirement for aplant w
4、aste acid and in the preparation of the lime slurry; the pH, the time,temperature, and other conditions of treatment may be adjusted toconform to plant practice. Otherwise the test shall be performed asdescribed in this method.NOTE 2Under some conditions of test the lime requirement may varysubstant
5、ially from that indicated by ultimate chemical analysis or by theuse of a determination of available alkalinity by titration to a stoichio-metric end point.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of
6、 this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.3 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the
7、Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C50 Practice for Sampling, Sample Preparation, Packaging,and Marking of Lime
8、and Limestone ProductsE70 Test Method for pH of Aqueous Solutions With theGlass Electrode3. Terminology3.1 Definitions:3.1.1 neutralization coeffcientthe number of parts of limerequired to neutralize one million parts by weight of sulfuricacid solution (1.5 %) to a pH of 4.4 in 30 min (see Note 1).3
9、.1.2 pHa measure of the hydrogen ion concentration of asample and representing the logarithm of the reciprocal (nega-tive logarithm) of the activity of hydrogen ions, calculated asfollows:pH 5 log1H!152logH1!where:H+= activity of hydrogen ions.4. Significance and Use4.1 Since all limes and waste aci
10、d solutions are different,this test method evaluates the relative quantity of a given limeneeded for the neutralization of a specific quantity of acid.4.2 Liming materials have a specific basicity factor ormeasure of alkalinity which can be used for comparing theirrelative neutralizing power. It avo
11、ids dependence on chemicalanalysis and is determined as grams of calcium oxide equiva-lents per kilogram of liming material.4.3 Likewise, specific waste acids have an acid value thatcan be expressed as grams of hydrochloric acid equivalent perlitre of acid waste. This value is related on a stoichiom
12、etricbasis to lime neutralization requirements of a liquid acid waste.5. Apparatus5.1 pH Measuring Apparatus, conforming to the require-ments of Section 5, Apparatus, and Section 6, Reagents andMaterials, of Test Method E70. A time-pH recording device orattachment is desirable but not required.5.2 A
13、nalytical Balance, capable of reproducing resultswithin 0.005 g.1These test methods are under the jurisdiction of ASTM Committee C07 onLime and Limestone and are the direct responsibility of Subcommittee C07.05 onChemical Tests.Current edition approved July 1, 2013. Published August 2013. Originally
14、approved in 1957. Last previous edition approved in 2006 as C400 98 (2006).DOI: 10.1520/C0400-98R13E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards
15、 Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision
16、 on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15.3 Stirrer, motorized, capable of rotating at speeds from120 to 600 r/min.5.4 Miscellaneous EquipmentChemically resistantglass
17、ware,3metal stands for support of the equipment, etc.6. Purity of Reagents6.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, wh
18、ere suchspecifications are available.4Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 Unless otherwise indicated, references to water shall beunderstood to mean distill
19、ed water.7. Test Method Afor Determining Lime Requirement forthe neutralization of a standard sulfuric acid or waste acidsolution within a time limit of thirty minutes.7.1 Reagents:7.1.1 Sulfuric Acid, Standard Solution (1.5 6 0.05 %)Thoroughly mix 15.8 g of concentrated sulfuric acid (95 %H2SO4) wi
20、th water, dilute to 1 L, analyze to within 0.005 %H2SO4, and store in a suitable stoppered bottle.7.2 Preparation of Sample:7.2.1 Take samples of quicklime and hydrated lime inaccordance with Methods C50.7.2.2 QuicklimeWeigh a sample of quicklime (2.50 60.01 g) ground to pass a No. 50 mesh sieve. Ad
21、d to a 500-mLtall-form beaker containing 50 mL of boiling water andcontinue to boil for 2 min. Remove from hot plate and continuestirring with a magnetic stirrer until the slurry reaches roomtemperature (at least 10 min).7.2.3 Hydrated LimeMix a sample of hydrated lime (2.506 0.01 g) with 50 mL of w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC40019982013E1STANDARDTESTMETHODSFORQUICKLIMEANDHYDRATEDLIMEFORNEUTRALIZATIONOFWASTEACID 中和 废酸用 生石灰

链接地址:http://www.mydoc123.com/p-466487.html