ASTM C185-2002 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥用灰浆的空气含量的标准试验方法》.pdf
《ASTM C185-2002 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥用灰浆的空气含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C185-2002 Standard Test Method for Air Content of Hydraulic Cement Mortar《水硬性水泥用灰浆的空气含量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 185 02American Association StateHighway and Transportation Officials StandardAASHTO No.: T137Standard Test Method forAir Content of Hydraulic Cement Mortar1This standard is issued under the fixed designation C 185; the number immediately following the designation indicates the year of
2、original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department
3、of Defense.1. Scope1.1 This test method covers the determination of the aircontent of hydraulic cement mortar under the conditionshereinafter specified.1.2 The values stated in SI units are to be regarded as thestandard.1.3 Values in SI shall be obtained by measurement in SIunits or by appropriate c
4、onversion, using the Rules for Con-version and Rounding in IEEE/ASTM SI 10, of measurementsmade in other units.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safe
5、ty and health practices and determine the applica-bility of regulatory limitations prior to use.1.5 Warning Fresh hydraulic cementitious mixtures arecaustic and may cause chemical burns to skin and tissue uponprolonged exposure.22. Referenced Documents2.1 ASTM Standards:C 91 Specification for Masonr
6、y Cement3C 109/C 109M Test Method for Compressive Strength ofHydraulic-Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)3C 150 Specification for Portland Cement3C 183 Practice for Sampling and the Amount of Testing ofHydraulic Cement3C 230/C 230M Specification for Flow Table for Use in Testsof Hyd
7、raulic Cement3C 305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic Consistency3C 511 Specification for Moist Cabinets, Moist Rooms, andWater Storage Tanks Used in the Testing of HydraulicCements and Concretes3C 595 Specification for Blended Hydraulic Cements3C 778 Sp
8、ecification for Standard Sand3C 1005 Specification for Weights and Weighing Devices forUse in the Physical Testing of Hydraulic Cements3C 1157 Performance Specification for Hydraulic Cement3C 1328 Specification for Plastic Stucco Cement3C 1328 Specification for Mortar Cement3E 438 Specification for
9、Glasses in Laboratory Apparatus4E 694 Specification for Laboratory Glass Volumetric Appa-ratus4IEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): The Modern Metric System43. Summary of Test Method3.1 Prepare a mortar with standard sand and the cement tobe tested, using a wate
10、r content sufficient to give a requiredflow. Compact the mortar into a measure of known volume anddetermine mass. Calculate the air content from the measureddensity of the mortar, the known densities of the constituents,and the mixture proportions.4. Significance and Use4.1 The purpose of this test
11、method is to determine whetheror not the hydraulic cement under test meets the air-entrainingor non-air-entraining requirements of the applicable hydrauliccement specification for which the test is being made. The aircontent of concrete is influenced by many factors other than thepotential of the ce
12、ment for air entrainment.5. Apparatus5.1 Flow Table, Flow Mold, and Caliper, shall conform toSpecification C 230/C 230M.5.2 MeasureA cylindrical measure having an inside di-ameter of 76 6 2 mm and a depth (approximately 88 mm)adjusted by standardization with water to contain 400 6 1mLat 23.0 6 2.0C
13、(Note 1). For the purposes of this test, thecapacity of the measure in millilitres is the mass of the watercontent of the measure, in grams, divided by 0.9976, nocorrection in mass being made for the buoyant effect of air. Themeasure shall have a uniform wall thickness. The thickness ofthe wall and
14、bottom shall not be less than 2.9 mm. The totalmass of the empty measure shall not be more than 900 g. The1This test method is under the jurisdiction of ASTM Committee C01 on Cementand is the direct responsibility of Subcommittee C01.21 on Air Entrainment.Current edition approved Aug. 10, 2002. Publ
15、ished September 2002. Originallypublished as C 185 44 T. Last previous edition C 185 01.2Refer to the section on Safety Precautions, “Manual of Cement Testing,”Annual Book of ASTM Standards, Vol 04.01.3Annual Book of ASTM Standards, Vol 04.01.4Annual Book of ASTM Standards, Vol 14.04.1Copyright ASTM
16、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.measure shall be made of a metal not attacked by the cementmortar.NOTE 1Calibrate the 400-mL measure by filling with distilled waterat 23.06 2.0C to a point where the meniscus extends appreciably abov
17、ethe top of the measure, placing a clean piece of plate glass on the top ofthe measure, and allowing the excess water to be squeezed out. Theabsence of air bubbles as seen through the glass ensures that the measureis completely full. Care shall be taken that the excess water is wiped fromthe sides o
18、f the container before weighing.5.3 Mixer, Bowl, and Paddle, shall conform to the apparatussection of Practice C 305.5.4 StraightedgeA steel straightedge not less than 200mm long and not less than 1.5 mm nor more than 3.5 mm inthickness.5.5 Weights and Weighing Devices, shall conform to Speci-ficati
19、on C 1005. Evaluate the weighing device for precisionand accuracy at a total load of 2 kg.5.6 Glass GraduatesGlass graduates of 250-mL capacity,conforming to the requirements of Specifications E 438 andE 694.5.7 Tamper, conforming to the requirements of Test MethodC 109/C 109M. The tamping face of t
20、he tamper shall be flatand at right angles to the length of the tamper.5.8 Tapping Stick, a piece of hard wood having a diameterof approximately 16 mm and a length of approximately 152mm.5.9 SpoonA metal restaurant-type serving spoon not lessthan 230 mm in length and with a bowl approximately 100 mm
21、in length.6. Temperature and Humidity6.1 Maintain the temperature of the room and dry materialsat 23.0 6 4.0 C.6.2 Condition the mixing water and the measure, if it isbeing calibrated at 23 6 2C.6.3 Maintain the relative humidity of the laboratory at notless than 50 %.7. Standard Sand7.1 Use sand co
22、nforming to the requirements of Specifica-tion C 778 for 2030 sand.8. Sampling8.1 Sample the cement in accordance with Practice C 183.9. Procedure9.1 BatchProportion the standard mortar using 350 gcement to 1400 g 2030 standard sand and sufficient water togive a flow of 8712 6 712 % when determined
23、in accordancewith 9.3.NOTE 2Test Method C 185 refers to hydraulic cements that complyunder Specification C 150, Specification C 595, and Performance Speci-fication C 1157. Masonry cements (see Specification C 91), mortar ce-ments (see Specification C 1329), and plastic cements (see SpecificationC 13
24、28) require different sand, mass, and flow. Refer to the applicablespecification.9.2 Mixing of MortarMix the mortar in accordance withPractice C 305.9.3 Flow DeterminationCarefully wipe dry the flow-tabletop and place the flow mold at the center of it. Using the spoon,place a layer of mortar about 2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1852002STANDARDTESTMETHODFORAIRCONTENTOFHYDRAULICCEMENTMORTAR 硬性 水泥 灰浆 空气 含量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-465914.html