ASTM C1405-2012 Standard Specification for Glazed Brick (Single Fired Brick Units)《釉面砖(单烧、砖砌块)的标准规格》.pdf
《ASTM C1405-2012 Standard Specification for Glazed Brick (Single Fired Brick Units)《釉面砖(单烧、砖砌块)的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1405-2012 Standard Specification for Glazed Brick (Single Fired Brick Units)《釉面砖(单烧、砖砌块)的标准规格》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1405 12Standard Specification forGlazed Brick (Single Fired, Brick Units)1This standard is issued under the fixed designation C1405; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers brick, having a ceramic glazefinish fused to the body during the same process as the unitbody firing, that are inte
3、nded for use in masonry and supplyingstructural or facing components, or both, to the structure. Thisspecification does not cover double-fired glazed brick. Somedouble-fired decorative glazes have physical properties whichvary from those of single-fired glazes due to the lowertemperatures used in ap
4、plying the decorative coating.1.2 The property requirements of this specification apply atthe time of purchase. The use of results from testing of brickextracted from masonry structures for determining confor-mance or nonconformance to the property requirements of thisspecification is beyond the sco
5、pe of this specification.1.3 Glazed brick are prismatic units available in a variety ofsizes, textures, colors, and shapes. Glazed brick are manufac-tured from clay, shale, or similar naturally occurring earthysubstances and subjected to a heat treatment at elevatedtemperatures (firing). The heat tr
6、eatment shall develop a firedbond between the particulate constituents to provide thestrength and durability requirements of this specification (seeTerminology C1232).1.4 Glazed brick are shaped during manufacture by mold-ing, pressing, or extrusion, and the shaping method is a way todescribe the br
7、ick.1.5 Glazed brick are classified into one of two grades, one oftwo types, one of two classes, and one of three divisions.1.6 Opacity of the glaze is not required unless specified bythe purchaser.1.7 The text of this standard references notes and footnoteswhich provide explanatory material. These
8、notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of this standard.1.8 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyan
9、d are not considered standard.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitation
10、s prior to use.2. Referenced Documents2.1 ASTM Standards:2C67 Test Methods for Sampling and Testing Brick andStructural Clay TileC1093 Practice for Accreditation of Testing Agencies forMasonryC1232 Terminology of MasonryE84 Test Method for Surface Burning Characteristics ofBuilding Materials2.2 NFPA
11、 Standard:NFPA No. 255 Test for Surface Burning Characteristics ofBuilding Materials32.3 UL Standard:UL No. 723 Flammability Studies of Cellular Plastics andOther Building Materials Used for Interior Finishes42.4 ICBO Standard:UBC No. 42-1 Test Method for Fire Hazard Classification ofBuilding Materi
12、al52.5 Federal Standard:Federal Standard Test No. 141 Abrasion Resistance (TaberAbraser)63. Terminology3.1 DefinitionsTerms used in this specification are definedin accordance with Terminology C1232.1This specification is under the jurisdiction of ASTM Committee C15 onManufactured Masonry Unitsand i
13、s the direct responsibility of SubcommitteeC15.02 on Brick and Structural Clay Tile.Current edition approved July 1, 2012. Published August 2012. Originallyapproved in 1998. Last previous edition approved in 2010 as C1405 10. DOI:10.1520/C1405-12.2For referenced ASTM standards, visit the ASTM websit
14、e, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/www.
15、nfpa.org.4Available from Underwriters Laboratories (UL), 333 Pfingsten Rd., North-brook, IL 60062-2096, http:/.5Available from the International Conference of Building Officials, 5360 SouthWorkman Mill Road, Whittier, CA 90601.6Available from U.S. Government Printing Office Superintendent of Documen
16、ts,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Classification4.1 GradesGrad
17、es classify glazed brick according to theirpermissible variation in face dimension as follows. Whengrade is not specified, the requirements for Grade S govern.4.1.1 Grade S (Standard), units for use where standarddimensional tolerances are desired.4.1.2 Grade SS (Select Sized), units for use where a
18、 higherdegree of precision and lower permissible variation in size aredesired.4.2 TypesTwo types of glazed brick are covered. Whentype is not specified, the requirements for Type I govern.4.2.1 Type I (Single-Faced Units), for general use whereonly one face is finished.4.2.2 Type II (Two-Faced Units
19、), for use where two oppositefaces are finished.4.3 ClassesTwo classes of glazed brick are covered.When class is not specified, the requirements for Class Exteriorgovern.4.3.1 Class Exterior, for exterior applications.4.3.2 Class Interior, for interior applications.4.4 DivisionsThree divisions of gl
20、azed brick are covered.Divisions identify the amount and placement of hollow spaces(cores, cells and deep frogs) in the cross section of the unit. Inthe Division nomenclature, H shall be understood to meanhollow, and V shall be understood to mean void.4.4.1 Division SolidBrick with void area less th
21、an orequal to 25 % of its gross cross sectional area, measured in anyplane parallel to the surface containing the cores, cells, or deepfrogs.4.4.2 Division H40VBrick with void area greater than25 % but less than or equal to 40 % of its gross cross sectionalarea, measured in any plane parallel to the
22、 surface containingthe cores, cells, or deep frogs.4.4.3 Division H60VBrick with void area greater than40 % but less than or equal to 60 % of its gross cross sectionalarea, measured in any plane parallel to the surface containingthe cores, cells, or deep frogs. The shell thicknesses shallcomply with
23、 the requirements in Table 1. See Fig. 1.5. Physical Properties5.1 DurabilityGlazed brick shall conform to the physicalproperties requirements for the class specified as prescribed inTable 2 or in 5.1.1 or 5.1.2. For the compressive strengthrequirements, test the unit with the compressive force perp
24、en-dicular to the bed surface of the unit, with the unit in thestretcher position.NOTE 1The physical property requirements for durability are basedupon correlation of these physical properties and freeze-thaw testing ofunits in standard production. They indicate durability. Conformance withthese pro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC14052012STANDARDSPECIFICATIONFORGLAZEDBRICKSINGLEFIREDBRICKUNITS 釉面砖 砌块 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-464526.html