ASTM C1318-1995(2001) Standard Test Method for Determination of Total Neutralizing Capability and Dissolved Calcium and Magnesium Oxide in Lime for Flue Gas Desulfurization (FGD)《烟.pdf
《ASTM C1318-1995(2001) Standard Test Method for Determination of Total Neutralizing Capability and Dissolved Calcium and Magnesium Oxide in Lime for Flue Gas Desulfurization (FGD)《烟.pdf》由会员分享,可在线阅读,更多相关《ASTM C1318-1995(2001) Standard Test Method for Determination of Total Neutralizing Capability and Dissolved Calcium and Magnesium Oxide in Lime for Flue Gas Desulfurization (FGD)《烟.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1318 95 (Reapproved 2001)Standard Test Method forDetermination of Total Neutralizing Capability and DissolvedCalcium and Magnesium Oxide in Lime for Flue GasDesulfurization (FGD)1This standard is issued under the fixed designation C 1318; the number immediately following the designati
2、on indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers analysis o
3、f magnesian, dolo-mitic and high-calcium limes for total neutralizing capabilityand dissolved major oxides. Dissolved calcium and magnesiumare the major species that neutralize acid under the conditionsof the test.1.2 The test conditions are chosen to measure the acid-neutralizing capacity of both c
4、alcium hydroxide and magne-sium hydroxide contained in slaked lime. By controlling theneutralization pH at 6, magnesium hydroxide and magnesiumoxide are titrated in addition to calcium hydroxide fraction.1.3 This test method also determines the fraction of Mg ionspresent in the lime that will dissol
5、ve under lime flue gasdesulfurization (FGD) conditions. Because the Mg+ion altersFGD performance, it is important to know its concentration.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard t
6、o establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 25 Test Methods for Chemical Analysis of Limestone,Quicklime, and Hydrated Lime2C 50 Practice for Sampling, Sample Preparation, Pac
7、king,and Marking of Lime and Limestone Products2C 51 Terminology Relating to Lime and Limestone (asUsed by the Industry)23. Terminology3.1 DefinitionsUnless otherwise specified, for definitionsof terms used in these test methods refer to Terminology C 51.4. Summary of Test Method4.1 Lime is slaked b
8、y boiling and is reacted with acid at apH and residence time similar to those found in full-scale FGDreaction tanks.4.2 A sample of lime is titrated with 1N hydrochloric acid,maintaining a pH of 6 for 30 min. After 30 min, the acidconsumption is recorded. The total neutralizing capacity iscalculated
9、 from the acid consumption and reported as CaO.Dissolved magnesium is determined by atomic absorptionspectrometry or by EDTA titration and reported as percentdissolved Magnesium Oxide (as MgO).5. Significance and Use5.1 There are existing lime-based flue gas desulfurizationunits in operation that re
10、quire a method to measure the oxidesavailable for sulfur dioxide absorption. Dissolved magnesiumoxide varies among limes depending on the limestone sourcesand calcination conditions.6. Interferences6.1 Any substance reacting with acid under the conditionsof the test will contribute to the total oxid
11、e and dissolved oxidevalues.6.2 Magnesium in forms other than MgO, which dissolveunder test conditions, may affect the dissolved MgO and totaloxide value.7. Apparatus7.1 Digital Readout pH Meter, with combination electrodereadable to 0.01 pH units, or an autotitrator with an automatictemperature com
12、pensator capable of titrating to a presetendpoint (Note 1).NOTE 1Use of an automatic titrator is recommended.7.2 Stirrers and Stir Bars.7.3 Atomic Absorption Spectrometer, if not using EDTAtitration.7.4 Filtering Funnel, Type AE glass fiber paper, volumetricflasks (size as needed), 500 mL volumetric
13、 flasks, and variousClass A pipettes.8. Reagents8.1 1.0 Normal Hydrochloric Acid, standardize using pro-cedures in Test Methods C 25, Section 28.1This test method is under the jurisdiction of ASTM Committee C07 on Limeand is the direct responsibility of Subcommittee C07.05 on Chemical Uses.Current e
14、dition approved Nov. 10, 1995. Published February 1996.2Annual Book of ASTM Standards, Vol 04.01.1Copyright ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.8.2 Distilled Water,CO2free.8.3 Calcium and Magnesium Standard Solutions (commer-cially available or use methods in
15、 Test Methods C 25, Section31).8.4 EDTA Standard Solution (0.4 %), standardize accordingto Test Methods C 25, Section 31.5, Standardization of EDTA.9. Sample Preparation9.1 The sampling and grinding of any lime sample shall becarried out as rapidly as possible, so that the absorption ofmoisture and
16、carbon dioxide is held to a minimum.9.2 The sample as received at the laboratory shall bethoroughly mixed and a representative sample with minimumweight of 100 g shall be taken and pulverized to pass a No. 50mesh sieve for analysis.9.3 The prepared sample shall be stored in a tightly cappedcontainer
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC131819952001STANDARDTESTMETHODFORDETERMINATIONOFTOTALNEUTRALIZINGCAPABILITYANDDISSOLVEDCALCIUMANDMAGNESIUMOXIDEINLIMEFORFLUEGASDESULFURIZATIONFGD

链接地址:http://www.mydoc123.com/p-464204.html