ASTM C1259-2008e1 Standard Test Method for Dynamic Youngs Modulus Shear Modulus and Poissons Ratio for Advanced Ceramics by Impulse Excitation of Vibration《用振动脉冲激励法的高级陶瓷动态杨氏模量、剪切模量.pdf
《ASTM C1259-2008e1 Standard Test Method for Dynamic Youngs Modulus Shear Modulus and Poissons Ratio for Advanced Ceramics by Impulse Excitation of Vibration《用振动脉冲激励法的高级陶瓷动态杨氏模量、剪切模量.pdf》由会员分享,可在线阅读,更多相关《ASTM C1259-2008e1 Standard Test Method for Dynamic Youngs Modulus Shear Modulus and Poissons Ratio for Advanced Ceramics by Impulse Excitation of Vibration《用振动脉冲激励法的高级陶瓷动态杨氏模量、剪切模量.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1259 081Standard Test Method forDynamic Youngs Modulus, Shear Modulus, and PoissonsRatio for Advanced Ceramics by Impulse Excitation ofVibration1This standard is issued under the fixed designation C 1259; the number immediately following the designation indicates the year oforiginal a
2、doption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEAdded research report footnote to Section 12.2 editorially in April 2009.1.
3、Scope1.1 This test method covers determination of the dynamicelastic properties of advanced ceramics at ambient tempera-tures. Specimens of these materials possess specific mechani-cal resonant frequencies that are determined by the elasticmodulus, mass, and geometry of the test specimen. Thedynamic
4、 elastic properties of a material can therefore becomputed if the geometry, mass, and mechanical resonantfrequencies of a suitable (rectangular, cylindrical, or discgeometry) test specimen of that material can be measured.Dynamic Youngs modulus is determined using the resonantfrequency in the flexur
5、al mode of vibration. The dynamic shearmodulus, or modulus of rigidity, is found using torsionalresonant vibrations. Dynamic Youngs modulus and dynamicshear modulus are used to compute Poissons ratio.1.2 This test method measures the fundamental resonantfrequency of test specimens of suitable geomet
6、ry by excitingthem mechanically by a singular elastic strike with an impulsetool. Specimen supports, impulse locations, and signal pick-uppoints are selected to induce and measure specific modes of thetransient vibrations. A transducer (for example, contact accel-erometer or non-contacting microphon
7、e) senses the resultingmechanical vibrations of the specimen and transforms theminto electric signals. (See Fig. 1.) The transient signals areanalyzed, and the fundamental resonant frequency is isolatedand measured by the signal analyzer, which provides a numeri-cal reading that is (or is proportion
8、al to) either the frequency orthe period of the specimen vibration. The appropriate funda-mental resonant frequencies, dimensions, and mass of thespecimen are used to calculate dynamic Youngs modulus,dynamic shear modulus, and Poissons ratio.1.3 Although not specifically described herein, this testm
9、ethod can also be performed at cryogenic and high tempera-tures with suitable equipment modifications and appropriatemodifications to the calculations to compensate for thermalexpansion, in accordance with sections 9.2, 9.3, and 10.4 ofC 1198.1.4 Where possible, the procedures, sample specifications
10、,and calculations in this test method are consistent with TestMethods C 623, C 747, C 848, and C 1198.1.5 This test method uses test specimens in bar, rod, anddisc geometries. The rod and bar geometries are described inthe main body. The disc geometry is addressed in Annex A1.1.6 A modification of t
11、his test method can be used forquality control and nondestructive evaluation, using changes inresonant frequency to detect variations in specimen geometryand mass and internal flaws in the specimen. (See 5.5).1.7 The values stated in SI units are to be regarded as thestandard.1.8 This standard does
12、not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standa
13、rds:2C 372 Test Method for Linear Thermal Expansion of Por-celain Enamel and Glaze Frits and Fired Ceramic Whitew-are Products by the Dilatometer Method1This test method is under the jurisdiction of ASTM Committee C28 onAdvanced Ceramics and is the direct responsibility of Subcommittee C28.01 onMech
14、anical Properties and PerformanceCurrent edition approved Jan. 1, 2008. Published January 2008. Originallyapproved in 1994. Last previous edition approved in 2001 as C 125901.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For
15、 Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.FIG. 1 Block Diagram of Typical Test Apparatus1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.C 623 Test Method for You
16、ngs Modulus, Shear Modulus,and Poissons Ratio for Glass and Glass-Ceramics byResonanceC 747 Test Method for Moduli of Elasticity and Fundamen-tal Frequencies of Carbon and Graphite Materials by SonicResonanceC 848 Test Method for Youngs Modulus, Shear Modulus,and Poissons Ratio For Ceramic Whiteware
17、s by Reso-nanceC 1145 Terminology of Advanced CeramicsC 1161 Test Method for Flexural Strength of AdvancedCeramics at Ambient TemperatureC 1198 Test Method for Dynamic Youngs Modulus, ShearModulus, and Poissons Ratio for Advanced Ceramics bySonic ResonanceD 4092 Terminology for Plastics: Dynamic Mec
18、hanicalPropertiesE6 Terminology Relating to Methods of Mechanical Test-ingE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 2001 Guide for Resonant Ultrasound Spectroscopy forDe
19、fect Detection in Both Metallic and Non-metallic Parts3. Terminology3.1 DefinitionsThe definitions of terms relating to me-chanical testing appearing in Terminology E6 should beconsidered as applying to the terms used in this test method.The definitions of terms relating to advanced ceramics appear-
20、ing in Terminology C 1145 should be considered as applying tothe terms used in this test method. Directly pertinent definitionsas listed in Terminologies E6, C 1145, and D 4092 are shownin the following paragraphs with the appropriate source givenin brackets.3.1.1 advanced ceramic, na highly enginee
21、red, high-performance, predominately nonmetallic, inorganic, ceramicmaterial having specific functional attributes. (C 1145)3.1.2 dynamic mechanical measurement, na technique inwhich either the modulus or damping, or both, of a substanceunder oscillatory load or displacement is measured as afunction
22、 of temperature, frequency, or time, or combinationthereof. (D 4092)3.1.3 elastic limit FL2, nthe greatest stress that amaterial is capable of sustaining without permanent strainremaining upon complete release of the stress. (E6)3.1.4 elastic modulus FL2, nthe ratio of stress to strainbelow the prop
23、ortional limit. (E6)3.1.5 Poissons ratio () nd, nthe absolute value of theratio of transverse strain to the corresponding axial strainresulting from uniformly distributed axial stress below theproportional limit of the material.3.1.5.1 DiscussionIn isotropic materials, Youngs Modu-lus (E), shear mod
24、ulus (G), and Poissons ratio () are relatedby the following equation: 5 E/2G! 1 (1)(E6)3.1.6 proportional limit FL2, nthe greatest stress that amaterial is capable of sustaining without deviation fromproportionality of stress to strain (Hookes law). (E6)3.1.7 shear modulus (G) FL2, nthe elastic modu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12592008E1STANDARDTESTMETHODFORDYNAMICYOUNGSMODULUSSHEARMODULUSANDPOISSONSRATIOFORADVANCEDCERAMICSBYIMPULSEEXCITATIONOFVIBRATION

链接地址:http://www.mydoc123.com/p-463957.html