ASTM C1224-2011 Standard Specification for Reflective Insulation for Building Applications《建筑设备反射绝热的标准规范》.pdf
《ASTM C1224-2011 Standard Specification for Reflective Insulation for Building Applications《建筑设备反射绝热的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1224-2011 Standard Specification for Reflective Insulation for Building Applications《建筑设备反射绝热的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1224 11Standard Specification forReflective Insulation for Building Applications1This standard is issued under the fixed designation C1224; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the general requirements andphysical properties of reflective insulations for use in buildingapplications. Th
3、ese insulation materials consist of one or morelow emittance surfaces, such as metallic foil or metallicdeposits, unmounted or mounted on substrates. Reflectiveinsulations derive thermal performance from surfaces with anemittance of 0.1 or less, facing enclosed air spaces.1.2 The values stated in in
4、ch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is
5、theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Hea
6、t Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC390 Practice for Sampling and Acceptance of ThermalInsulation LotsC518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC727 Practice for Installati
7、on and Use of Reflective Insula-tion in Building ConstructionsC1258 Test Method for Elevated Temperature and Humid-ity Resistance of Vapor Retarders for InsulationC1338 Test Method for Determining Fungi Resistance ofInsulation Materials and FacingsC1363 Test Method for Thermal Performance of Buildin
8、gMaterials and Envelope Assemblies by Means of a HotBox ApparatusC1371 Test Method for Determination of Emittance ofMaterials Near Room Temperature Using Portable Emis-sometersE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE96/E96M Test Methods for Water Vapor Transmission o
9、fMaterials2.2 TAPPI Standard:T512 Creasing of Flexible Packaging Material Paper Speci-mens for Testing33. Terminology3.1 DefinitionsTerminology C168 shall apply to the termsin this specification.4. Ordering Information4.1 Prior to purchase, for sampling and acceptance proce-dures, Practice C390 is a
10、n option when agreed upon by thepurchaser and the manufacturer.4.2 Specify the required thermal resistance by the directionof the heat flow.4.3 Specify the width, depth, and total area to be insulated.4.4 Specify special markings, when required.5. Materials and Manufacture5.1 Reflective insulation m
11、aterials shall consist of lowemittance surface(s) with, or without, substrates and adhesivesrequired to meet the specified thermal performance and physi-cal properties.5.2 Multiple layer reflective insulations shall be designed toattain the intended separation of layers in normal application.Such mu
12、ltiple layer insulation shall form an attachment flangesuitable for stapling, or other means of attachment.1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.21 onReflective Insulation.Current edition approved
13、 May 15, 2011. Published July 2011. Originallyapproved in 1993. Last previous edition approved in 2009 as C122409. DOI:10.1520/C1224-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume in
14、formation, refer to the standards Document Summary page onthe ASTM website.3Available from Technical Association of the Pulp and Paper Industry (TAPPI),15 Technology Parkway South, Norcross, GA 30092, http:/www.tappi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
15、ocken, PA 19428-2959, United States.5.3 DimensionsInsulation shall be furnished in dimen-sions to fit framing members, at spacings standard in theconstruction industry, or as specifically agreed upon betweenthe producer and the buyer.6. Physical Properties Requirements6.1 Low emittance materials sha
16、ll have a surface with anemittance of 0.1 or less, as determined in accordance with 9.1.6.2 PermeanceWhen the reflective insulation is to serveas a vapor retarder, the permeance of the material shall notexceed one perm, as determined in accordance with 9.2.6.2.1 When the reflective insulation is to
17、be vapor transmit-ting the permeance of the material shall be equal to or greaterthan five perms, as determined in accordance with 9.2.6.3 Surface Burning CharacteristicsBuilding code re-quirements specify flame spread and smoke developmentvalues determined in accordance with 9.3, except as follows:
18、(1) Maximum surface burning characteristics shall not ex-ceed 25 flame spread index and 50 smoke development indexfor inside plenum applications.(2) Maximum surface burning characteristics shall not ex-ceed 25 flame spread index and 450 smoke development indexin exposed building applications.6.4 Hum
19、idity ResistanceThe laminates of the reflectiveinsulation shall be tested in accordance with 9.4. Threespecimens shall be exposed. Shield the test specimens fromcondensate that drips from the ceiling of the humidity chamber.6.4.1 The specimens shall be evaluated for visible corrosionand delamination
20、. For purposes of corrosion evaluation disre-gard the outer 0.25 in. (6.4 mm) perimeter. No tested specimenshall exhibit visible crystalline deposits exceeding 2 % of thetest area nor exhibit unaided delamination of layers.6.5 Adhesive Performance:6.5.1 BleedingAdhesives, when used, shall show no si
21、gnof bleeding when tested in accordance with the test procedurein 9.5.1. Disregard bleeding at cut edges. Bleeding or delami-nation, covering over 2 % of the specimen area, shall be causefor rejection.6.5.2 PliabilitySpecimens tested in accordance with thetest procedure in 9.5.2 shall not show crack
22、ing or delamination.6.6 Fungi ResistanceSpecimens shall not have growthgreater than comparative item when tested in accordance with9.6. Use Interpretation of Results (Paragraph 7.2) of TestMethod C1338.6.7 Thermal ResistanceDetermine the thermal resistancein accordance with procedures in 9.7. The re
23、sults of theprocedures shall indicate the R-value of the product, in theassembly tested.7. Workmanship, Finish, and Appearance7.1 The insulation shall be manufactured, packaged, andshipped in such a manner that, when received by the customer,it shall be suitable for installation in accordance with P
24、racticeC727.8. Sampling8.1 Sampling shall be performed in accordance with Prac-tice C390.9. Test Methods9.1 EmittanceThe emittance of the product shall be testedin accordance with Test Method C1371.9.2 PermeanceThe permeance of the product shall betested in accordance with Test Method E96/E96M, Desi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12242011STANDARDSPECIFICATIONFORREFLECTIVEINSULATIONFORBUILDINGAPPLICATIONS 建筑设备 反射 绝热 标准规范 PDF

链接地址:http://www.mydoc123.com/p-463811.html