ASTM C1179-2015 Standard Test Method for Oxidation Mass Loss of Manufactured Carbon and Graphite Materials in Air《人造碳和石墨材料在空气中的氧化质量损耗的标准试验方法》.pdf
《ASTM C1179-2015 Standard Test Method for Oxidation Mass Loss of Manufactured Carbon and Graphite Materials in Air《人造碳和石墨材料在空气中的氧化质量损耗的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1179-2015 Standard Test Method for Oxidation Mass Loss of Manufactured Carbon and Graphite Materials in Air《人造碳和石墨材料在空气中的氧化质量损耗的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1179 91 (Reapproved 2010)1C1179 15 An American National StandardStandard Test Method forOxidation Mass Loss of Manufactured Carbon and GraphiteMaterials in Air1This standard is issued under the fixed designation C1179; the number immediately following the designation indicates the year
2、 oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEUpdated units of measurement throughout the standard editorial
3、ly in May 2010.1. Scope Scope*1.1 This test method provides a comparative oxidation mass loss of manufactured carbon and graphite materials in air.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not
4、purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Summary of Test Method2.1 The test method
5、 determines mass loss characteristics of carbon and graphite articles in air as a function of temperature andtime by subjecting standard size specimens to muffle furnace exposure and then comparing pre-test and post-test mass differentials.3. Significance and Use3.1 This test method is primarily con
6、cerned with the oxidation mass loss of manufactured carbon and graphite materials in airat temperatures from 371371 C to 677C.677 C.3.2 The test method will provide acceptable results at preselected test temperatures that yield less than 10 % mass loss in 100h. 100 h. These results can be used to de
7、termine relative service temperatures.4. Interferences4.1 Results can be affected by materials released by the furnace walls or furniture.These materials may be present from previousoxidation test samples or other furnace use. It is recommended that the furnace be operated at 1093C1093 C for 1 h 1 h
8、 priorto use for oxidation mass loss testing.4.2 The validity of this test method depends upon the availability of oxygen to the test specimen. The door of the furnace shallbe kept closed to maintain temperature control; however, the furnace door shall not be sealed, rendering the door airtight.4.3
9、Due to factors beyond the scope of the test method that might cause significant differences, this test method is only usefulfor comparative results.5. Apparatus5.1 Muffle Furnace, with automatic temperature regulation with64C precision. Furnace chamber volume 983983 cm3 to 2458cm2458 cm3.NOTE 1Comme
10、rcially available muffle furnaces advertised to achieve 611C611 C can be set up to achieve the necessary precision.5.2 Thermocouple, K-type (chromel/alumel with Type 304 stainless steel sheath).5.3 Digital Thermometer, for temperature readout.5.4 Crucible Tongs.1 This test method is under the jurisd
11、iction of ASTM Committee D02 on Petroleum Products Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.F0 on Manufactured Carbon and Graphite Products.Current edition approved May 1, 2010Dec. 1, 2015. Published May 2010January 2016. Originally approved in 1991.
12、 Last previous edition approved in 2005 as C1179 91 (2005).(2010)1. DOI: 10.1520/C1179-91R10E01.10.1520/C1179-15.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not
13、be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end
14、of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.5 Glazed Crucibles, flat bottom.25.6 Quart Glass Tray, or equivalent.5.7 Nylon Gloves, lint-free.5.8 Paper, lint-free.5.9 Analytical Balance, with 0.001-g0.001 g resolu
15、tion.5.10 Desiccator, charged with indicating desiccant.6. Sample Preparation6.1 All specimens are to be handled with lint-free nylon gloves or equivalent during all machining, handling, impregnation, andtesting. Specimens should be kept free of contamination by placing them on clean nonmetallic sur
16、faces during all operations. Oncethe specimens have been oxidized, direct handling is not recommended.6.2 Test specimens are to consist of right cylinders 25.4-mm25.4 mm diameter by 25.4 mm long 6 0.3 mm. 25.4 mm long60.3 mm. Specimens are to be machined all over with carbide-tipped tools to achieve
17、 a surface roughness visually comparableto 0.8-m.0.8 m. arithmetic average (AA).6.3 Wipe specimens with lint-free paper to remove carbon machining dust.6.4 Specimens and crucibles are to be clearly identified. To avoid sample contamination, use a carbide-tipped scribe to markthe specimens. Crucibles
18、 can be marked with ceramic ink.6.5 Place each specimen to be tested on its side (cylindrical surface) in a dried, tared crucible. Specimens are to be kept in thesame crucible for the test duration. Record the individual identification numbers for each specimen/crucible set.6.6 Dry the specimen/cruc
19、ible sets in a vented oven at 120120 C to 150C150 C for a minimum of 2 h. 2 h. Remove thespecimen/crucible sets and cool in a desiccator for a minimum of 30 min 30 min to achieve room temperature.7. Procedure7.1 Before the running of this test method, the operator should practice the transferring of
20、 similar shaped specimens fromfurnace to desiccator. The specimen/crucible set should be transferred so that the specimen is exposed to the atmosphere for nolonger than 30 s. 30 s. The desiccator should be in the immediate vicinity of the furnace.7.2 Preheat and stabilize the furnace to the designat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC11792015STANDARDTESTMETHODFOROXIDATIONMASSLOSSOFMANUFACTUREDCARBONANDGRAPHITEMATERIALSINAIR 人造 石墨

链接地址:http://www.mydoc123.com/p-463642.html