ASTM C114-2009a Standard Test Methods for Chemical Analysis of Hydraulic Cement.pdf
《ASTM C114-2009a Standard Test Methods for Chemical Analysis of Hydraulic Cement.pdf》由会员分享,可在线阅读,更多相关《ASTM C114-2009a Standard Test Methods for Chemical Analysis of Hydraulic Cement.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C114 09aStandard Test Methods forChemical Analysis of Hydraulic Cement1This standard is issued under the fixed designation C114; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in pa
2、rentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods cover the chemical analyses ofhydraulic cements. Any test methods of demonstrated accept-able precision and bias may be used fo
3、r analysis of hydrauliccements, including analyses for referee and certification pur-poses, as explained in Section 3. Specific chemical testmethods are provided for ease of reference for those desiring touse them. They are grouped as Reference Test Methods andAlternative Test Methods. The reference
4、 test methods are longaccepted classical chemical test methods which provide areasonably well-integrated basic scheme of analysis for hy-draulic cements. The alternative test methods generally provideindividual determination of specific components and may beused alone or as alternates and determinat
5、ions within the basicscheme at the option of the analyst and as indicated in theindividual method.1.2 Contents:Section Subject2 Referenced Documents3 Number of Determinations and Permissible Variations3.1 Referee Analyses3.2 Optional Analyses3.3 Performance Requirements for Rapid Test Methods3.4 Pre
6、cision and Bias4 General4.1 Interferences and Limitations4.2 Apparatus and Materials4.3 Reagents4.4 Sample Preparation4.5 General Procedures4.6 Recommended Order for Reporting AnalysesReference Test Methods5 Insoluble Residue6 Silicon Dioxide6.2 Cements with Insoluble Residue Less Than 1 %6.3 Cement
7、s with Insoluble Residue Greater Than 1 %7 Ammonium Hydroxide Group8 Ferric Oxide9 Phosphorus Pentoxide10 Titanium Dioxide11 Zinc Oxide12 Aluminum Oxide13 Calcium Oxide14 Magnesium Oxide15 Sulfur15.1 Sulfur Trioxide15.2 Sulfide16 Loss On Ignition16.1 Portland Cement16.2 Portland Blast-Furnace Slag C
8、ement and Slag Cement17 Sodium and Potassium Oxides17.1 Total Alkalis17.2 Water-Soluble Alkalis18 Manganic Oxide19 Chloride20 Chloroform-Soluble Organic SubstancesAlternative Test Methods21 Calcium Oxide22 Carbon Dioxide23 Magnesium Oxide24 Loss on Ignition24.1 Portland Blast-Furnace Slag Cement and
9、 Slag Cement25 Titanium Dioxide26 Phosphorus Pentoxide27 Manganic Oxide28 Free Calcium OxideAppendices TitleAppendix X1 Example of Determination of Equivalence Pointfor the Chloride DeterminationAppendix X2 CO2Determinations in Hydraulic Cements1.3 The values stated in SI units are to be regarded as
10、standard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the
11、applica-bility of regulatory limitations prior to use. See 6.3.2.1 and14.4.1 for specific caution statements.2. Referenced Documents2.1 ASTM Standards:2C25 Test Methods for Chemical Analysis of Limestone,Quicklime, and Hydrated LimeD1193 Specification for Reagent WaterE29 Practice for Using Signific
12、ant Digits in Test Data toDetermine Conformance with SpecificationsE275 Practice for Describing and Measuring Performance1These test methods are under the jurisdiction of ASTM Committee C01 onCement and are the direct responsibility of Subcommittee C01.23 on CompositionalAnalysis.Current edition app
13、roved Dec. 1, 2009. Published January 2010. Originallyapproved in 1934. Last previous edition approved in 2009 as C114 09. DOI:10.1520/C0114-09a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
14、volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.of Ultraviolet and Visible Spectrop
15、hotometersE350 Test Methods for Chemical Analysis of Carbon Steel,Low-Alloy Steel, Silicon Electrical Steel, Ingot Iron, andWrought IronE617 Specification for Laboratory Weights and PrecisionMass StandardsE832 Specification for Laboratory Filter Papers3. Number of Determinations and Permissible Vari
16、ations3.1 Referee AnalysesWhen conformance to chemicalspecification requirements is questioned, perform refereeanalyses as described in 3.1.1. The reference test methods thatfollow in Sections 5-20, or other test methods qualifiedaccording to 3.3, are required for referee analysis. A cementshall not
17、 be rejected for failure to conform to chemicalrequirements unless all determinations of constituents involvedand all necessary separations prior to the determination of anyone constituent are made entirely by these methods. Whenreporting the results of referee analyses, specify which testmethods we
18、re used.3.1.1 Referee analyses shall be made in duplicate and theanalyses shall be made on different days. If the two results donot agree within the permissible variation given in Table 1, thedetermination shall be repeated until two or three results agreewithin the permissible variation. When two o
19、r three results doagree within the permissible variation, their average shall beaccepted as the correct value. When an average of either two orthree results can be calculated, the calculation shall be based onthe three results. For the purpose of comparing analyses andcalculating the average of acce
20、ptable results, the percentagesshall be calculated to the nearest 0.01 (or 0.001 in the case ofchloroform-soluble organic substances), although some of theaverage values are reported to 0.1 as indicated in the testmethods. When a blank determination (See Note 1) is speci-fied, one shall be made with
21、 each individual analysis or witheach group of two or more samples analyzed on the same dayfor a given component.NOTE 1A blank determination is a procedure which follows all stepsof analysis but in the absence of a sample. It is used for detection andcompensation of systematic bias.3.1.2 Referee ana
22、lyses or analyses intended for use as abasis for acceptance or rejection of a cement or for manufac-turers certification shall be made only after demonstration ofprecise and accurate analyses by the test methods in use bymeeting the requirements of 3.1.3, except when demonstratedunder 3.3.2.1. Such
23、demonstration may be made concurrentlywith analysis of the cement being tested and must have beenmade within the preceding two years. The requirements forverification of equipment and personnel are summarized inTable 2. The demonstration is required only for those constitu-ents being used as a basis
24、 for acceptance, rejection, orcertification of a cement, but may be made for any constituentof cement for which a standard exists.3.1.3 Initial qualification of the analyst shall be demon-strated by analysis of each constituent of concern in at least oneCRM cement (Note 2) no matter what test method
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1142009ASTANDARDTESTMETHODSFORCHEMICALANALYSISOFHYDRAULICCEMENTPDF

链接地址:http://www.mydoc123.com/p-463512.html