ASTM C1019-2007 Standard Test Method for Sampling and Testing Grout《灌浆取样和测试的标准试验方法》.pdf
《ASTM C1019-2007 Standard Test Method for Sampling and Testing Grout《灌浆取样和测试的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1019-2007 Standard Test Method for Sampling and Testing Grout《灌浆取样和测试的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1019 07Standard Test Method forSampling and Testing Grout1This standard is issued under the fixed designation C 1019; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses
2、 indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers procedures for both field andlaboratory sampling
3、and compression testing of grout used inmasonry construction. Grout for masonry is specified underSpecification C 476.NOTE 1The testing agency performing this test method should beevaluated in accordance with Practice C 1093.1.2 The values stated in inch-pound units are to be regardedas the standard
4、.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced
5、Documents2.1 ASTM Standards:2C 39/C 39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC 143/C 143M Test Method for Slump of Hydraulic-Cement ConcreteC 476 Specification for Grout for MasonryC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Ta
6、nks Used in theTesting of Hydraulic Cements and ConcretesC 617 Practice for Capping Cylindrical Concrete Speci-mensC 1064/C 1064M Test Method for Temperature of FreshlyMixed Hydraulic-Cement ConcreteC 1093 Practice for Accreditation of Testing Agencies forMasonryC 1611/C 1611M Test Method for Slump
7、Flow of Self-Consolidating Concrete3. Significance and Use3.1 Grout used in masonry is a fluid mixture of cementitiousmaterials and aggregate with a high water content for ease ofplacement.3.1.1 During construction, grout is placed within or betweenabsorptive masonry units. Excess water must be remo
8、ved fromgrout specimens in order to provide compressive strength testresults more nearly indicative of the grout strength in the wall.In this test method, molds are made from masonry units havingthe same absorption and moisture content characteristics asthose being used in the construction.3.2 This
9、test method is used to either help select groutproportions by comparing test values or as a quality control testfor uniformity of grout preparation during construction.3.3 The physical exposure condition and curing of the groutare not exactly reproduced, but this test method does subjectthe grout sp
10、ecimens to absorption conditions similar to thoseexperienced by grout in the wall.NOTE 2Test results of grout specimens taken from a wall should notbe compared to test results obtained with this test method.4. Apparatus4.1 Maximum-Minimum Thermometer.4.2 Straightedge, a steel straightedge not less t
11、han 6 in.(152.4 mm) long and not less than116 in. (1.6 mm) inthickness.4.3 Tamping Rod, a nonabsorbent rod, either round orsquare in cross section nominally58 in. (15.9 mm) in dimen-sion with ends rounded to hemispherical tips of the samediameter. The rod shall be a minimum length of 12 in. (304.8mm
12、).4.4 Nonabsorbent Blocks and Spacers, nonabsorbent, rigidsquares and rectangles with side dimensions so as to achievethe desired grout specimen side dimensions and of sufficientquantity or thickness to yield the desired grout specimenheight, as shown in Fig. 1, Fig. 2, and Fig. 3.NOTE 3Nonabsorbent
13、 blocks may be of plastic, wood, or othernonabsorbent material. Certain species of wood contain sugars which1This test method is under the jurisdiction of ASTM Committee C12 on Mortarsand Grouts for Unit Masonry and is the direct responsibility of SubcommitteeC12.02 on Research and Methods of Test.C
14、urrent edition approved July 15, 2007. Published July 2007. Originallyapproved in 1984. Last previous edition approved in 2005 as C 1019 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volum
15、e information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.cause retardation of cement. In order to
16、 prevent this from occurring, newwooden blocks shall be soaked in limewater for 24 h, sealed with varnishor wax, or covered with an impermeable material prior to use.4.5 Panels and plates, pieces of34 in. (19 mm) plywoodwith dimensions as needed to contain units and grout speci-mens. Soak in limewat
17、er for 24 h, seal with varnish or wax, orcover with an impermeable material prior to use. A nonabsor-bant material of equivalent stiffness to the plywood is permit-ted.PROCEDURES5. Test Specimens5.1 Each grout specimen shall have a square cross-section,3 in. (76 mm) or larger on the sides and twice
18、as high as itswidth. Dimensional tolerances shall be within 5 % of the widthselected.5.2 Test at least three specimens at each age specified.NOTE 4Frequency of sampling and age of test is to be determined bythe specifier of this test method and is usually found in the constructiondocuments.6. Mold C
19、onstruction6.1 Select a level location where the molds remain undis-turbed for up to 48 h.NOTE 5The location of specimen construction should be protectedand as free from perceptible vibration as possible.6.2 The construction of the mold shall simulate the in-situconstruction. If the grout is placed
20、between two different typesof masonry units, both types shall be used to construct themold.6.3 Form a space with a square cross-section, 3 in. (76 mm)or larger on each side and twice as high as its width, bystacking masonry units of the same type and moisture condi-tion as those being used in the co
21、nstruction. The surface of theunit in contact with the grout specimen shall not have beenpreviously used to mold specimens. Place nonabsorbentblocks, cut to proper size and of the proper thickness orquantity, at the bottom of the space to achieve the necessaryheight of specimen. Tolerance on space a
22、nd specimen dimen-sions shall be within 5 % of the specimen width. See Fig. 1,Fig. 2, and Fig. 3and accompanying notes.NOTE 6Other methods of obtaining grout specimens and specimensof different geometry have been employed in grout testing, but are notdescribed in this test method. Other methods used
23、 to obtain groutspecimens include: drilling grout-filled cores of regular units; filling coresof masonry units specifically manufactured to provide grout specimens;filling compartments in slotted corrugated cardboard boxes specificallymanufactured to provide grout specimens; and forming specimens fr
24、omdifferent sized masonry units of the same or similar material.Since test results vary with methods of forming and specimen geometry,comparative test results between the specimen described in this testmethod and the proposed specimen should be required and confined to asingle specimen shape and met
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC10192007STANDARDTESTMETHODFORSAMPLINGANDTESTINGGROUT 灌浆 取样 测试 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-463068.html