ASTM B311-2017 Standard Test Method for Density of Powder Metallurgy (PM) Materials Containing Less Than Two Percent Porosity《孔隙度小于2%的粉末冶金(PM)材料密度的标准试验方法》.pdf
《ASTM B311-2017 Standard Test Method for Density of Powder Metallurgy (PM) Materials Containing Less Than Two Percent Porosity《孔隙度小于2%的粉末冶金(PM)材料密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B311-2017 Standard Test Method for Density of Powder Metallurgy (PM) Materials Containing Less Than Two Percent Porosity《孔隙度小于2%的粉末冶金(PM)材料密度的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B311 13B311 17Standard Test Method forDensity of Powder Metallurgy (PM) Materials ContainingLess Than Two Percent Porosity1This standard is issued under the fixed designation B311; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This tes
3、t method covers the determination of density for powder metallurgy (PM) materials containing less than two percentporosity and for cemented carbides. This test method is based on the water displacement method.NOTE 1A test specimen that gains mass when immersed in water indicates the specimen contain
4、s surface-connected porosity. Unsealed surfaceporosity will absorb water and cause density values higher than the true value. This test method is not applicable if this problem occurs.1.2 With the exception of the values for density and the mass used to determine density, for which the use of the gr
5、am per cubiccentimetercentimetre (g/cm3) and gram (g) units is the long-standing industry practice, the values in SI units are to be regardedas standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of t
6、his standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles f
7、or the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2B243 Terminology of Powder MetallurgyE691 Practice for Conducting an Interlaboratory Study to Determi
8、ne the Precision of a Test MethodE456 Terminology Relating to Quality and Statistics3. Terminology3.1 Definitions of powder metallurgy (PM) terms can be found in Terminology B243. Additional descriptive material isavailable in the Related Material section of Vol. 02.05 of the Annual Book of ASTM Sta
9、ndards.4. Summary of Test Method4.1 Using an analytical balance, the test specimen is first weighed in air and then in water. The density is determined bycalculation using Archimedes principle.5. Significance and Use5.1 For PM materials containing less than two percent porosity, a density measuremen
10、t may be used to determine if the part hasbeen densified, either overall or in a critical region, to the degree required for the intended application. Density alone cannot beused for evaluating the degree of densification because chemical composition and heat treatment affect the pore-free density.1
11、 This test method is under the jurisdiction ofASTM Committee B09 on Metal Powders and Metal Powder Products and is the direct responsibility of Subcommittee B09.11on Near Full Density Powder Metallurgy Materials.Current edition approved April 1, 2013April 1, 2017. Published June 2013April 2017. Orig
12、inally approved in 1956. Last previous edition approved in 2008 as B311 08.DOI: 10.1520/B0311-13.10.1520/B0311-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the
13、 standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes acc
14、urately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbo
15、r Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 For cemented carbides, a density measurement is normally used to determine if there is any significant deviation incomposition of the carbide grade. For straight tungsten carbide-cobalt grades, the relationship is straightforw
16、ard. For complexcarbide grades (for example, grades containing tantalum carbide or titanium carbide, or both, in addition to tungstencarbide-cobalt), the situation is more complicated. If the measured density is beyond the specified limits, the composition is outsideof the specified limits. A measur
17、ed density within the specified limits does not ensure correct composition; compensation betweentwo or more constituents could result in the expected density with the wrong composition. Density alone cannot be used forevaluating a cemented carbide grade.6. Apparatus6.1 Analytical Balanceprecision si
18、ngle-pan analytical balance that will permit readings within 0.01% of the test specimenmass. The analytical balance shall be supported in a manner to eliminate mechanical vibrations and be shielded from air drafts.See Table 1.6.2 Weighing LiquidDistilled or deionized water to which 0.05 to 0.1 volum
19、e percent of a wetting agent has been added toreduce the effects of surface tension.NOTE 2Degassing the water by evacuation, boiling, or ultrasonic agitation helps to prevent air bubbles from collecting on the test specimen andspecimen support when immersed in water.6.3 Water ContainerA glass beaker
20、 or other suitable transparent container should be used to contain the water.NOTE 3A transparent container makes it easier to see air bubbles adhering to the test specimen and specimen support when immersed in water.NOTE 4For the most precise density determination, the water container should be of a
21、 size that the level of the water does not rise more than 2.5mm when the test specimen is lowered into the water.6.4 Test Specimen Support for Weighing in WaterTwo typical arrangements are shown in Fig. 1. The suspension wire may betwisted around the test specimen or the test specimen may be support
22、ed in a wire basket that is attached to the suspension wire.For either arrangement, a single corrosion resistant wirefor example, austenitic stainless steel, copper, nichromeshall be usedfor the basket and suspension wire. For the maximum recommended diameter of suspension wire to be used for variou
23、s massranges see Table 2.NOTE 5For the most precise density determinations, it is important that the mass and volume of all supporting wires immersed in water be minimized.6.5 ThermometerA thermometer with an accuracy of0.2 C to measure the temperature of the water.7. Preparation of Test Specimens7.
24、1 A complete part or a section of a part may be used for the test specimen. For the highest precision, the test specimen shallhave a minimum mass of 5.0 g. If less precision can be tolerated, several test specimens may be used to reach the minimum mass,provided each test specimen has a mass of not l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB3112017STANDARDTESTMETHODFORDENSITYOFPOWDERMETALLURGYPMMATERIALSCONTAININGLESSTHANTWOPERCENTPOROSITY

链接地址:http://www.mydoc123.com/p-460915.html