ASTM B117-2018 Standard Practice for Operating Salt Spray (Fog) Apparatus.pdf
《ASTM B117-2018 Standard Practice for Operating Salt Spray (Fog) Apparatus.pdf》由会员分享,可在线阅读,更多相关《ASTM B117-2018 Standard Practice for Operating Salt Spray (Fog) Apparatus.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B117 16B117 18Standard Practice forOperating Salt Spray (Fog) Apparatus1This standard is issued under the fixed designation B117; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p
2、arentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This practice covers the apparatus, procedure, and condition
3、s required to create and maintain the salt spray (fog) testenvironment. Suitable apparatus which may be used is described in Appendix X1.1.2 This practice does not prescribe the type of test specimen or exposure periods to be used for a specific product, nor theinterpretation to be given to the resu
4、lts.1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establ
5、ish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Princ
6、iples for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2B368 Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test)D609 P
7、ractice for Preparation of Cold-Rolled Steel Panels for Testing Paint, Varnish, Conversion Coatings, and Related CoatingProductsD1193 Specification for Reagent WaterD1654 Test Method for Evaluation of Painted or Coated Specimens Subjected to Corrosive EnvironmentsE70 Test Method for pH of Aqueous So
8、lutions With the Glass ElectrodeE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodG85 Practice for Modified Salt Spray (Fog) Testing3. Significance and Use3.1 This practice provides a controlled corrosive environment which has been utilized to produce r
9、elative corrosion resistanceinformation for specimens of metals and coated metals exposed in a given test chamber.3.2 Prediction of performance in natural environments has seldom been correlated with salt spray results when used as standalone data.3.2.1 Correlation and extrapolation of corrosion per
10、formance based on exposure to the test environment provided by thispractice are not always predictable.3.2.2 Correlation and extrapolation should be considered only in cases where appropriate corroborating long-term atmosphericexposures have been conducted.3.3 The reproducibility of results in the s
11、alt spray exposure is highly dependent on the type of specimens tested and theevaluation criteria selected, as well as the control of the operating variables. In any testing program, sufficient replicates should1 This practice is under the jurisdiction ofASTM Committee G01 on Corrosion of Metals and
12、 is the direct responsibility of Subcommittee G01.05 on Laboratory CorrosionTests.Current edition approved March 15, 2016Aug. 1, 2018. Published April 2016October 2018. Originally approved in 1939. Last previous edition approved in 20112016 asB117 11.B117 16. DOI: 10.1520/B0117-16.10.1520/B0117-18.2
13、 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to
14、provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof
15、the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1be included to establish the variability of the results. Variability has been observed when similar specimens
16、are tested in differentfog chambers even though the testing conditions are nominally similar and within the ranges specified in this practice.4. Apparatus4.1 The apparatus required for salt spray (fog) exposure consists of a fog chamber, a salt solution reservoir, a supply of suitablyconditioned com
17、pressed air, one or more atomizing nozzles, specimen supports, provision for heating the chamber, and necessarymeans of control. The size and detailed construction of the apparatus are optional, provided the conditions obtained meet therequirements of this practice.4.2 Drops of solution which accumu
18、late on the ceiling or cover of the chamber shall not be permitted to fall on the specimensbeing exposed.4.3 Drops of solution which fall from the specimens shall not be returned to the solution reservoir for respraying.4.4 Material of construction shall be such that it will not affect the corrosive
19、ness of the fog.4.5 All water used for this practice shall conform to Type IV water in Specification D1193 (except that for this practice limitsfor chlorides and sodium may be ignored). This does not apply to running tap water. All other water will be referred to as reagentgrade.NOTE 1Water used wit
20、h a conductivity 1.0 S/cm (or resistivity 1.0 Mcm) may cause damage to some equipment due to the reactive nature ofthe water. In addition, it may cause issues with stabilizing pH measurements.5. Test Specimens5.1 The type and number of test specimens to be used, as well as the criteria for the evalu
21、ation of the test results, shall be definedin the specifications covering the material or product being exposed or shall be mutually agreed upon between the purchaser andthe seller.6. Preparation of Test Specimens6.1 Specimens shall be suitably cleaned. The cleaning method shall be optional dependin
22、g on the nature of the surface and thecontaminants. Care shall be taken that specimens are not recontaminated after cleaning by excessive or careless handling.6.2 Specimens for the evaluation of paints and other organic coatings shall be prepared in accordance with applicablespecification(s) for the
23、 material(s) being exposed, or as agreed upon between the purchaser and the supplier. Otherwise, the testspecimens shall consist of steel meeting the requirements of Practice D609 and shall be cleaned and prepared for coating inaccordance with the applicable procedure of Practice D609.6.3 Specimens
24、coated with paints or nonmetallic coatings shall not be cleaned or handled excessively prior to test.6.4 Whenever it is desired to determine the development of corrosion from an abraded area in the paint or organic coating, ascratch or scribed line shall be made through the coating with a sharp inst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB1172018STANDARDPRACTICEFOROPERATINGSALTSPRAYFOGAPPARATUSPDF

链接地址:http://www.mydoc123.com/p-460382.html