1、ASD-STAN STANDARD NORME ASD-STAN ASD-STAN NORM prEN 2234 Edition P 3 November 2010 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATIONAvenue de Tervuren, 270 - B-1150 Brussels - Tel. + 32 2 775 8126 - Fax. + 32 2 775 8131 - www.asd-stan.orgICS: Supersedes Editio
2、n P2 October 2001 Descriptors: ENGLISH VERSION Aerospace series Cable, electrical, fire resistant Technical specification Srie arospatiale Cbles lectriques rsistant au feu Spcification technique Luft- und Raumfahrt Elektrische Leitungen, feuerbestndig Technische Lieferbedingungen This “Aerospace Ser
3、ies“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved by the experts of the concerned Domain following
4、member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination and review by users and formal agreement of ASD-ST
5、AN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national level by giving the EN the status of a national standard
6、and by withdrawing any national standards conflicting with the EN. Edition approved for publication 1 November 2010 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2010 by ASD-STAN prEN 2234:2010 (E) 2 Contents Page Foreword2 1 Scope 3
7、2 Normative references 3 3 Definitions and symbols .3 4 Materials and construction .3 5 Required characteristics.5 6 Tests method5 7 Quality assurance8 8 Identification marking 10 9 Packaging, labelling, and delivery lengths 10 Foreword This standard was reviewed by the Domain Technical Coordinator
8、of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN 2234:2010 (E) 3 1 Scope This standard specifies the required characteristics and test
9、procedures for fire resistant or fire-proof electrical cables for use in aircraft electrical systems. These cables shall also maintain a specific surface resistance when they are subjected to a flame of 1 100 C after 5 minutes (fire resistant) or 15 minutes (fire-proof) exposure. They shall be rated
10、 at an a.c. voltage of 600 V r.m.s., a frequency of maximum 2 000 Hz and a long term temperature of up to 260 C (ambient temperature plus temperature rise in conductor). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated refere
11、nces, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3475-100 (all parts), Aerospace series Cables, electrical, aircraft use Test methods Part 100: General EN 3838, Aerospace series Requirements and tests o
12、n user-applied markings on aircraft electrical cables EN 9133, Aerospace series Quality management systems Qualification procedure for aerospace standard parts ISO 2574, Aircraft Electrical cables Identification marking ISO 8815, Aircraft Electrical cables and cable harnesses Vocabulary IEC 60028:19
13、25 , International standard of resistance for copper 3 Definitions and symbols For the purposes of this document, the definitions and symbols given in ISO 8815 and EN 3475-100 apply. 4 Materials and construction 4.1 Conductors 4.1.1 Materials The individual strands used for the conductors shall be c
14、ylindrical and shall be: of nickel clad copper alloy for nominal cross section of 0,4 mm2; of nickel clad copper for nominal sections 0,6 mm2. prEN 2234:2010 (E) 4 The copper shall meet the requirements of IEC 28 and the copper alloy the requirements of this standard. The nickel shall not represent
15、less than 27 % of the total mass of the individual strand. Individual strands shall show the following minimum breaking strength: 280 N/mm2for nickel clad copper; 315 N/mm2for nickel clad copper alloy. 4.1.2 Lay length Up to 9 mm2cross section inclusive (code 090), concentric or unilay conductors ar
16、e used. The lay for the stranded conductor, checked over the outside layer of a test piece 1 m long, shall be between 8 times and 16 times the maximum diameter of this conductor. For sectional areas between 14 mm2and 68 mm2(codes 140 to 680), the conductor comprises concentric or bunched conductors
17、twisted together. The lay of the strands for the basic concentric or bunched conductors shall not exceed 30 times the diameter of the concentric or bunched conductor in question. The lay for concentric (or bunched) conductors, measured over the outer layer of the conductor, shall be between 8 times
18、and 16 times the maximum conductor diameter. In all cases the lay of the outer layer shall be left-hand. 4.1.3 Joints The conductors shall be free from any joints. Each strand comprising the conductors may, however, include soldered or brazed joints. For strands with a diameter of 0,25 mm or greater
19、, butt joints shall be used. The distance between two joints in individual strands shall exceed 3 m, measured between different strands. 4.1.4 Compaction Compaction of the causing deformation of the strands or damage to the plating is not permitted. 4.2 Construction Finished cables The insulation sh
20、all be of a material, which takes on the circular shape of the conductor throughout its length. It shall closely cover the conductor without adhering to it, so that it reduces the corona effect and the risk of blistering and heat corrosion due to voids and gaseous discharges. The insulation shall be
21、 neither too tight nor too loose, so as to provide satisfactory mechanical characteristics and be easily removable using commercially available tools. (See 6.45) The protective sheath shall be of a material, which takes on the round shape of the insulated conductor lying under it. It shall provide a
22、dequate protection from mechanical damage and contamination by liquids, as specified in the product standard. The outer surface shall be smooth and suitable for identification marking. The protective sheath shall not have a corrosive effect on the screen and shall be resistant to fungus and other. p
23、rEN 2234:2010 (E) 5 5 Required characteristics The characteristics of the cables, tested according to the methods described hereafter shall comply with the values given in the product standard. 6 Tests method See Table 1. Table 1 Tests: methods, application, requirements Tests Each delivery No. Desc
24、ription EN 3475- (and/or particulars) Qualification 1) (Clause 7).aOn all cables (7.2.1 and 7.2.2)Priorto deliverPeriodic every three years (7.2.4) Requirements (and/or particulars) 6 Test conditions 100 X X X X 6.1 Visual examination 201 3 X Product standard 6.2 Mass 202 minimum length 0,5 m 3 X Pr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASDSTANPREN22342010AEROSPACESERIESCABLEELECTRICALFIRERESISTANTTECHNICALSPECIFICATIONEDITIONP3PDF

链接地址:http://www.mydoc123.com/p-450733.html